NONINVASIVE ESTIMATION OF CORONARY FLOW RESERVE BY TRANSESOPHAGEAL DOPPLER MEASUREMENT OF CORONARY SINUS FLOW

被引:28
|
作者
SIOSTROZONEK, P
KRANZ, A
HEINZ, G
RODLER, S
GOSSINGER, H
KREINER, G
STUMPFLEN, A
ZEHETGRUBER, M
SCHWARZ, M
WEBER, H
机构
[1] 2nd Department of Medicine, Division of Cardiology, University of Vienna, A-1090 Vienna
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1993年 / 72卷 / 17期
关键词
D O I
10.1016/0002-9149(93)90314-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Currently available methods for the measurement of coronary flow reserve (CFR) are invasive and time-consuming, and need adequate laboratory equipment and staff.1-4 Furthermore, most of these methods are limited by various methodologic problems.5,6 Transesophageal echocardiography enables visualization of the distal coronary sinus in most patients. Accordingly, we investigated the ability of transesophageal echocardiography to calculate CFR by Doppler measurement of coronary sinus flow (CSF) at rest and after dipyridamole administration. © 1993.
引用
收藏
页码:1334 / 1337
页数:4
相关论文
共 50 条
  • [1] Estimation of coronary flow reserve by contrast enhanced transesophageal coronary sinus Doppler measurements in patients with type 2 diabetes mellitus
    Nishino, M
    Suna, S
    Taniike, M
    Egami, Y
    Takeda, T
    CIRCULATION, 2002, 106 (19) : 422 - 422
  • [2] Comparison of transesophageal coronary sinus and left anterior descending coronary artery Doppler measurements for the assessment of coronary flow reserve
    Mundigler, G
    Zehetgruber, M
    Christ, G
    Siostrzonek, P
    CLINICAL CARDIOLOGY, 1997, 20 (03) : 225 - 231
  • [3] EVALUATION OF CORONARY FLOW RESERVE IN SYNDROME-X BY TRANSESOPHAGEAL MEASUREMENTS OF CORONARY SINUS FLOW
    ZEHETGRUBER, M
    KREINER, G
    ZEILER, K
    CHRIST, G
    GOTTSAUNERWOLF, M
    MORTL, D
    PROBST, P
    SIOSTRZONEK, P
    CIRCULATION, 1993, 88 (04) : 66 - 66
  • [4] Estimation of coronary sinus blood flow and coronary flow reserve by transthoracic echocardiography
    Ismail, YA
    Abdelmessih, NK
    Wong, I
    Soldo, S
    Chandraratna, PAN
    CIRCULATION, 1996, 94 (08) : 146 - 146
  • [5] Detection of in-stent restenosis by noninvasive Doppler measurement of coronary flow reserve
    Pizzuto, F
    Voci, P
    Mariano, E
    Puddu, PE
    Monti, F
    Sardella, G
    Romeo, F
    CIRCULATION, 2001, 104 (17) : 456 - 456
  • [6] TRANSESOPHAGEAL VERSUS INTRACORONARY DOPPLER ASSESSMENT OF CORONARY FLOW RESERVE
    ZEHETGRUBER, M
    PORENTA, G
    MUNDIGLER, G
    BINDER, T
    MORTL, D
    CHRIST, G
    PROBST, P
    MAURER, G
    SIOSTRZONEK, P
    CIRCULATION, 1995, 92 (08) : 709 - 709
  • [7] ESTIMATION OF CORONARY FLOW RESERVE BY TRANSESOPHAGEAL CORONARY SINUS DOPPLER MEASUREMENTS IN PATIENTS WITH SYNDROME-X AND PATIENTS WITH SIGNIFICANT LEFT CORONARY-ARTERY DISEASE
    ZEHETGRUBER, M
    MUNDIGLER, G
    CHRIST, G
    MORTL, D
    PROBST, P
    BAUMGARTNER, H
    MAURER, G
    SIOSTRZONEK, P
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (05) : 1039 - 1045
  • [8] Coronary flow reserve by contrast enhanced transesophageal coronary sinus Doppler measurements can evaluate diabetic microvascular dysfunction
    Nishino, Masami
    Hoshida, Shiro
    Egami, Yasuyuki
    Kondo, Isao
    Shutta, Ryu
    Yamaguchi, Hitoshi
    Tanaka, Kenjiro
    Tanouchi, Jun
    Hori, Masatsugu
    Yamada, Yoshio
    CIRCULATION JOURNAL, 2006, 70 (11) : 1415 - 1420
  • [9] Noninvasive measurement of coronary flow reserve in prediction of restenosis
    Djordjevic-Dikic, A.
    Beleslin, B.
    Ostojic, M.
    Stepanovic, J.
    Giga, V.
    Stojkovic, S.
    Tesic, M.
    Nedeljkovic, M.
    Petrasinovic, Z.
    Vukcevic, V.
    EUROPEAN HEART JOURNAL, 2010, 31 : 369 - 369
  • [10] TRANSFEMORAL CATHETERIZATION OF THE CORONARY SINUS BY DOPPLER CATHETERS FOR DETERMINATION OF CORONARY FLOW RESERVE