A SAMPLING STRATEGY FOR OFFICE NOISE MEASUREMENTS

被引:1
|
作者
BEHAR, A
MOLINARI, L
MALLETTE, R
机构
[1] Industrial Hygiene Department, Health and Safety Division, Ontario Hydro, 757 McKay Road, Pickering, Ontario, Canada L1W 3C8
关键词
Noise; Acoustic;
D O I
10.1016/0003-682X(90)90036-T
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A study was performed to derive a strategy for the measurement of representative office noise indices, such as Leq, Ln, etc., by comparing short-duration samples with whole-day measures. The study was performed using dosimeters in 12 office locations with different activities. For the locations measured, it was found that short-duration measurements can provide reliable estimates of whole-day noise levels. Five- or 15-minute samples collected shortly before or after noon break would best represent whole-day Leq and some Ln levels. © 1990.
引用
收藏
页码:313 / 320
页数:8
相关论文
共 50 条
  • [1] NOISE IN MEASUREMENTS OBTAINED BY SAMPLING
    WHITE, DR
    CLARE, JF
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (01) : 1 - 16
  • [2] Assessing the influence of the sampling strategy on the uncertainty of environmental noise measurements through the bootstrap method
    Mateus, Mario
    Carrilho, Joao A. Dias
    Gameiro da Silva, Manuel C.
    [J]. APPLIED ACOUSTICS, 2015, 89 : 159 - 165
  • [3] A sampling wattmeter for noise power measurements
    Callegaro, L
    Pisani, M
    [J]. Noise in Devices and Circuits III, 2005, 5844 : 284 - 293
  • [4] NOISE EXPOSURE - SAMPLING STRATEGY AND RISK ASSESSMENT
    BEHAR, A
    PLENER, R
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1984, 45 (02): : 105 - 109
  • [5] MAGIC SAMPLING - A DIGITAL SAMPLING STRATEGY THAT DISCRIMINATES AGAINST MAINS INTERFERENCE (NOISE)
    DEUTSCHER, RL
    FLETCHER, S
    [J]. ELECTROCHIMICA ACTA, 1990, 35 (11-12) : 1797 - 1804
  • [6] An experience sampling study of employees' reactions to noise in the open-plan office
    Ayoko, Oluremi B.
    Ashkanasy, Neal M.
    Li, Yiqiong
    Dorris, Alana
    Jehn, Karen A.
    [J]. JOURNAL OF BUSINESS RESEARCH, 2023, 155
  • [7] STATISTICAL-ANALYSIS OF THE NOISE IN FLUORESCENCE MEASUREMENTS BY THE SAMPLING TECHNIQUE
    ANDREONI, A
    CUBEDDU, R
    DESILVESTRI, S
    LAPORTA, P
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1981, 52 (06): : 849 - 851
  • [8] OFFICE ENDOMETRIAL SAMPLING
    COHEN, SA
    HURT, WG
    [J]. MEDICAL COLLEGE OF VIRGINIA QUARTERLY, 1980, 16 (1-2): : 46 - 48
  • [9] OFFICE AEROALLERGEN SAMPLING
    DIAMOND, MA
    [J]. ALLERGY PROCEEDINGS, 1992, 13 (03): : 143 - 146
  • [10] A noise autocovariance model for SAR altimeter measurements with implications for optimal sampling
    Ehlers, Frithjof
    Slobbe, Cornelis
    Verlaan, Martin
    Kleinherenbrink, Marcel
    [J]. ADVANCES IN SPACE RESEARCH, 2023, 71 (10) : 3951 - 3967