SUTURELESS END-TO-END BOWEL ANASTOMOSIS USING ND-YAG AND WATER-SOLUBLE INTRALUMINAL STENT

被引:29
|
作者
COSTELLO, AJ
JOHNSON, DE
CROMEENS, DM
WISHNOW, KI
VONESCHENBACH, AC
RO, JY
机构
[1] UNIV TEXAS,MD ANDERSON CANC CTR,DEPT UROL,BOX 110,1515 HOLCOMBE BLVD,HOUSTON,TX 77030
[2] UNIV TEXAS,MD ANDERSON CANC CTR,DEPT VET MED,HOUSTON,TX 77030
[3] UNIV TEXAS,MD ANDERSON CANC CTR,DEPT PATHOL,HOUSTON,TX 77030
关键词
bowel welding; intraluminal stent; Nd; tissue fusion; YAG laser;
D O I
10.1002/lsm.1900100211
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Sutureless end‐to‐end intestinal anastomoses were successfully constructed in 20 rabbits. A water‐soluble intraluminal stent was used to approximate the tissue edges, and the anastomotic seam was lased with 1.06 μm neodymium:YAG (Nd:YAG) laser energy supplied through a hand‐held 600‐μm gas‐cooled noncontact optical fiber. A continuous 5‐watt wave of power was applied over periods ranging from 46 to 92 seconds to produce the tissue blanching and shrinkage that indicated a satisfactory tissue weld. Integrity, degree of tissue reaction, and bursting pressures of the anastomoses were compared to those of anastomoses constructed using standard sutured techniques. The results of the two methods were equivalent at 1 to 3 days, but the laser‐fused enteric anastomoses showed less inflammatory reaction and greater bursting pressures at 7 and 14 days. Application of a variety of proteinaceous solutions including extracellular matrix materials and epidermal growth factors prior to lasing failed to augment wound healing. We conclude that lasers show promise as reconstructive, in addition to ablative, surgical instruments. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:179 / 184
页数:6
相关论文
共 21 条
  • [1] SUTURELESS BOWEL ANASTOMOSIS USING ND-YAG LASER
    MERCER, CD
    PAULI, B
    CANADIAN JOURNAL OF SURGERY, 1987, 30 (04) : 298 - 298
  • [2] SUTURELESS BOWEL ANASTOMOSIS USING ND-YAG LASER
    MERCER, CD
    MINICH, P
    PAULI, B
    LASERS IN SURGERY AND MEDICINE, 1987, 7 (06) : 503 - 506
  • [3] SUTURELESS BOWEL ANASTOMOSIS USING ND-YAG LASER
    MERCER, CD
    MINICH, P
    PAULI, B
    LASERS IN SURGERY AND MEDICINE, 1987, 7 (01) : 90 - 90
  • [4] Usefulness of venous catheter as an intraluminal stent for end-to-end venous anastomosis
    Tetsuyoshi Horiuchi
    Yoshinari Miyaoka
    Takatoshi Hasegawa
    Kiyoshi Ito
    Kazuhiro Hongo
    Acta Neurochirurgica, 2018, 160 : 1139 - 1141
  • [5] Usefulness of venous catheter as an intraluminal stent for end-to-end venous anastomosis
    Horiuchi, Tetsuyoshi
    Miyaoka, Yoshinari
    Hasegawa, Takatoshi
    Ito, Kiyoshi
    Hongo, Kazuhiro
    ACTA NEUROCHIRURGICA, 2018, 160 (06) : 1139 - 1141
  • [6] END-TO-END TUBAL ANASTOMOSIS USING AN ABSORBABLE STENT
    ANSARI, AH
    FERTILITY AND STERILITY, 1979, 32 (02) : 197 - 201
  • [7] THE 1ST SUTURELESS, LASER-WELDED, END-TO-END BOWEL ANASTOMOSIS
    SAUER, JS
    HINSHAW, JR
    MCGUIRE, KP
    LASERS IN SURGERY AND MEDICINE, 1989, 9 (01) : 70 - 73
  • [8] NONSUTURE MICROVASCULAR ANASTOMOSIS USING AN ND-YAG LASER AND A WATER-SOLUBLE POLYVINYL-ALCOHOL SPLINT
    NIIJIMA, KH
    YONEKAWA, Y
    HANDA, H
    TAKI, W
    JOURNAL OF NEUROSURGERY, 1987, 67 (04) : 579 - 583
  • [9] MICROVASCULAR END-TO-SIDE ARTERIAL ANASTOMOSIS USING THE ND-YAG LASER
    SHAPIRO, S
    SARTORIUS, C
    SANDERS, S
    CLARK, S
    NEUROSURGERY, 1989, 25 (04) : 584 - 589
  • [10] Sutureless end-to-end bowel anastomosis in rabbit using low-power CO2 laser
    Zhong Rong Li Yong Long Chi Run Cong Ke Department of Pediatric Surgery
    World Journal of Gastroenterology, 2000, 6 (04) : 557 - 560