'Boating' Out Migrated Dexamethasone Implant; Surgical Management of Removal of Anterior Chamber Migrated Dexamethasone Intravitreal Implant: A Case Report

被引:1
|
作者
Teo, B. H. [1 ]
Safinaz, M. K. [1 ]
Mae-Lynn, C. B. [1 ]
Amin, A. [1 ]
Edward, R. [2 ]
Mushawiahti, M. [1 ]
机构
[1] Univ Kebangsaan Malaysia, Med Ctr, Dept Ophthalmol, Jalan Yaacob Latif, Kuala Lumpur 56000, Malaysia
[2] Royal Victorian Eye & Ear Hosp, 32 Gisborne St, East Melbourne, Vic 3002, Australia
来源
MEDICINE AND HEALTH-KUALA LUMPUR | 2018年 / 13卷 / 02期
关键词
Dexamethasone; device removal; intravitreal injection; ophthalmologic surgical procedures;
D O I
10.17576/MH.2018.1302.18
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
It is rare for anterior chamber migration of an Ozurdex (R) implant from vitreous cavity, but it is seen more frequently in aphakic eyes or in pseudophakic cases with zonular dehiscense. We describe a case of a middle-aged gentleman who had persistent diabetic macular oedema not responding to anti-VEGF (vascular endothelium growth factor), who was treated with intravitreal Ozurdex (R) in his post vitrectomized eye and developed anterior migration of the implant to the anterior chamber. Anterior dislocation of an intravitreal implant of dexamethasone can be managed by repositioning it to the vitreous cavity or removing it through a corneal limbal incision. Ozurdex (R) is a friable implant, especially after a few weeks of implantation. Therefore, removal of the implant by grasping or aspiration may lead to its fracture or dispersion of the implant material. This is a report of a simple,fast and effective technique to remove a migrated Ozurdex (R) from the anterior chamber using a modified silicone tip.
引用
收藏
页码:175 / 179
页数:5
相关论文
共 50 条
  • [1] Repositioning of dexamethasone intravitreal implant (Ozurdex ®) migrated into the anterior chamber
    Vela J.I.
    Crespí J.
    Andreu D.
    [J]. International Ophthalmology, 2012, 32 (6) : 583 - 584
  • [2] Management of anterior chamber dislocation of a dexamethasone intravitreal implant: A case report
    Pacella F.
    Agostinelli E.
    Carlesimo S.C.
    Nebbioso M.
    Secondi R.
    Forastiere M.
    Pacella E.
    [J]. Journal of Medical Case Reports, 10 (1)
  • [3] Removal of a migrated dexamethasone implant (Ozurdex) from the anterior chamber using an intravenous cannula
    Ku, Jae Yee
    Mercieca, Karl
    Yau, Kenneth
    [J]. BMJ CASE REPORTS, 2021, 14 (07)
  • [4] Modified No-Touch Technique for Removal of a Dexamethasone Implant that has Migrated to the Anterior Chamber
    Stewart, Jay M.
    [J]. OCULAR IMMUNOLOGY AND INFLAMMATION, 2020, 28 (02) : 238 - 239
  • [5] Surgical Management of Anterior Chamber Migration of a Dexamethasone Intravitreal Implant
    Stelton, Christopher R.
    Townsend, Justin
    Peterson, Luke T.
    Khurana, Rahul N.
    Yeh, Steven
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2015, 46 (07): : 756 - 759
  • [6] No-Touch Removal of Anterior Segment-Migrated Dexamethasone Implant
    Rahimy, Ehsan
    Pitcher, John D.
    Abbey, Ashkan M.
    Garretson, Bruce R.
    Haller, Julia A.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (11): : 2414 - 2416
  • [7] Dislocation in the anterior chamber of a dexamethasone intravitreal implant
    Cousin, Marie
    Hoffart, Louis
    Baeteman, Christophe
    Matonti, Frederic
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2013, 48 (04): : E62 - E63
  • [8] Management and Complications of Dexamethasone Intravitreal Implant Migration Into the Anterior Chamber
    Betsch, Devin M.
    Gupta, R. Rishi
    [J]. JOURNAL OF VITREORETINAL DISEASES, 2022, 6 (06) : 432 - 436
  • [9] Anterior chamber migration of a dexamethasone implant: a case report
    Berisha, Bujar
    Hoeflechner, Lukas
    Wedrich, Andreas
    [J]. SPEKTRUM DER AUGENHEILKUNDE, 2021, 35 (02) : 83 - 87
  • [10] Risk factors for and management of anterior chamber intravitreal dexamethasone implant migration
    D. Röck
    K. U. Bartz-Schmidt
    T. Röck
    [J]. BMC Ophthalmology, 19