Heavy Ion Beam Scanning System of DC-110 Accelerator

被引:0
|
作者
Gikal, B. N. [1 ]
Gorbachev, E. V. [1 ]
Lebedev, N. I. [1 ]
Fateev, A. A. [1 ]
机构
[1] Joint Inst Nucl Res, Dubna, Russia
关键词
D O I
10.1134/S1547477110070277
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
A heavy ion acceleration complex for industrial applications based on the DC-110 cyclotron has been developed at the Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research. It is planned to irradiate polymer films with a width of up to 600 mm at this complex. This paper presents a design of a system for scanning heavy ion beam which offers uniform film irradiation at a beam energy of up to 2.5MeV/nucleon. The general concept of the two-channel scanning system and the design of the main deflecting magnets are described.
引用
收藏
页码:553 / 556
页数:4
相关论文
共 50 条
  • [1] Heavy Ion DC-110 Cyclotron for Industrial Applications and Applied Studies in Nanotechnologies
    Gikal, B. N.
    Gulbekyan, G. G.
    Dmitriev, S. N.
    Bogomolov, S. L.
    Borisov, O. N.
    Ivanenko, I. A.
    Kazarinov, N. Yu.
    Kazacha, V. I.
    Kalagin, I. V.
    Kolesov, I. V.
    Sazonov, M. N.
    Tikhomirov, A. V.
    Franko, J.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2010, 7 (07) : 557 - 559
  • [2] Development, creation, and startup of the DC-110 heavy ion cyclotron complex for industrial production of track membranes
    Gikal B.N.
    Dmitriev S.N.
    Gul'bekyan G.G.
    Apel' P.Y.
    Bogomolov S.L.
    Borisov O.N.
    Buzmakov V.A.
    Verevochkin V.A.
    Efremov A.A.
    Ivanenko I.A.
    Ivanov G.N.
    Kazarinov N.Y.
    Kazacha V.I.
    Kalagin I.V.
    Kolesov I.V.
    Kononov V.M.
    Korolev A.A.
    Kostyrev V.A.
    Lomovtsev A.M.
    Mel'nikov V.N.
    Mironov V.I.
    Pashchenko S.V.
    Sokolov V.A.
    Osipov N.F.
    Tikhomirov A.V.
    Fateev A.A.
    Khabarov M.V.
    Physics of Particles and Nuclei Letters, 2014, 11 (2) : 137 - 150
  • [3] A room temperature electron cyclotron resonance ion source for the DC-110 cyclotron
    Efremov, A.
    Bogomolov, S.
    Lebedev, A.
    Loginov, V.
    Yazvitsky, N.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [4] Ion Beam Scanning System for EG-5 Accelerator
    Ledo Pereda, L. M.
    Semenov, V. N.
    Rikhvitsky, V. S.
    Likhachev, A. N.
    Isaev, R. Sh.
    Chepurchenko, I. A.
    Doroshkevich, A. S.
    Alexandrov, V. A.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2024, 21 (04) : 938 - 945
  • [5] Correction of Vertical Displacement of Extracted Beam during Commissioning Tests of the DC-110 Cyclotron
    Gigal, B. N.
    Ivanenko, I. A.
    Kazarinov, N. Yu.
    Kalagin, I. V.
    Mironov, V. I.
    Samsonov, E. V.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2014, 11 (02) : 151 - 157
  • [6] Beam delivery characteristics of the Hitachi carbon ion scanning system at Osaka Heavy Ion Medical Accelerator in Kansai (HIMAK)
    Tsubouchi, Toshiro
    Beltran, Chris J.
    Yagi, Masashi
    Hamatani, Noriaki
    Takashina, Masaaki
    Shimizu, Shinichi
    Kanai, Tatsuaki
    Furutani, Keith M.
    MEDICAL PHYSICS, 2024, 51 (03) : 2239 - 2250
  • [7] Development of an ion beam analyzing system for the KBSI heavy-ion accelerator
    Bahng, Jungbae
    Hong, Jonggi
    Park, Jin Yong
    Kim, Seong Jun
    Ok, Jung -Woo
    Choi, Seyong
    Shin, Chang Seouk
    Yoon, Jang-Hee
    Won, Mi-Sook
    Lee, Byoung-Seob
    Kim, Eun-San
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [8] External beam for the Heavy Ion Accelerator Facility
    Shaharuddin, S.
    Stuchbery, J.
    Simpson, E. C.
    Gan, Z. K.
    Green, A. C.
    Cho, A.
    Lu, E.
    HEAVY ION ACCELERATOR SYMPOSIUM (HIAS 2019), 2020, 232
  • [9] Numerical Simulation of Ions Acceleration and Extraction in Cyclotron DC-110
    Samsonov, E. V.
    Gikal, B. N.
    Borisov, O. N.
    Ivanenko, I. A.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2014, 11 (02) : 158 - 168
  • [10] Beam Scanning System of an Industrial Electron Accelerator
    Borisov, M. A.
    Shvedunov, V. I.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2024, 79 (02) : 291 - 300