Multi-dimensional void fraction measurement of transient boiling two-phase flow in a heated rod bundle

被引:10
|
作者
Arai, Takahiro [1 ]
Furuya, Masahiro [1 ]
Kanai, Taizo [1 ]
Shirakawa, Kenetsu [1 ]
Nishi, Yoshihisa [1 ]
机构
[1] Cent Res Inst Elect Power Ind, 2-11-1 Iwadokita, Komae, Tokyo 2018511, Japan
来源
MECHANICAL ENGINEERING JOURNAL | 2015年 / 2卷 / 05期
关键词
Boiling two-phase flow; Rod bundle; Subchannel void sensor; Void fraction; Phasic velocity; Bubble chord length;
D O I
10.1299/mej.15-00163
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A subchannel void sensor (SCVS) was developed to measure the cross-sectional distribution of void fraction in a 5x5 heated rod bundle with o.d. 10 mm and heated length 2000 mm, and applied to a boiling two-phase flow experiment under the atmospheric pressure condition assuming at an accident or in a spent fuel pool in a boiling water reactor (BWR). The SCVS comprises 6-wire by 6-wire and 5-rod by 5-rod electrodes. The wire electrodes of 0.2 mm in diameter are arranged in lattice patterns between the rod bundle, while the electric conductance value in a region near one wire and another corresponds to local void fraction in the central-subchannel region. The local void fractions at 32 points (= 6x6-4) can be obtained as a cross-sectional distribution. The local void fractions near the rod surface at 100 points (= 4x25) can be also estimated by the conductance value in a region between one wire and one rod. The devised sensors are installed at five height levels along the axis to acquire two-phase flow behavior. A pair of SCVS is mounted at each level and placed 30 mm apart to estimate the one-dimensional phasic velocity distribution based on the cross-correlation analysis of both layers. The temporal resolution of void fraction measurement is 1600 frames (cross-sections) per second. The axial and radial power profile of the heated rod bundle are uniform, and eight pairs of sheath thermocouples are embedded on the heated rod to monitor its surface temperature distribution. The boiling two-phase flow experiment, which simulated a boil-off process, was conducted with the devised SCVS and experimental data was acquired under various inlet flow velocity, rod bundle power and inlet subcooling conditions. The experimental results were presented by the axial and cross-sectional distributions of void fraction, phasic velocity and bubble-chord length.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] DEVELOPMENT OF A MULTI-DIMENSIONAL MEASUREMENT SENSOR OF VOID FRACTION AND PHASIC VELOCITY FOR BOILING TWO-PHASE FLOW IN A 5x5 HEATED ROD BUNDLE
    Arai, Takahiro
    Furuya, Masahiro
    Kanai, Taizo
    Shirakawa, Kenetsu
    Nishi, Yoshihisa
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 2A, 2014,
  • [2] Three-dimensional void fraction measurement of two-phase flow in a rod bundle by neutron radiography
    Takenaka, Nobuyuki
    Asano, Hitoshi
    Fujii, Terushige
    Wada, Tetsumasa
    Matsubayashi, Masahito
    Tsuruno, Akira
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 377 (01): : 115 - 118
  • [3] Three-dimensional void fraction measurement of two-phase flow in a rod bundle by neutron radiography
    Takenaka, N
    Asano, H
    Fujii, T
    Wada, T
    Matsubayashi, M
    Tsuruno, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (01): : 115 - 118
  • [4] Drift-flux modeling of void fraction for boiling two-phase flow in a tight-lattice rod bundle
    Hibiki, Takashi
    Miwa, Shuichiro
    Katono, Kenichi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 180
  • [5] On void fraction distribution during two-phase boiling flow instability
    Yeoh, GH
    Tu, JY
    Li, Y
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (02) : 413 - 417
  • [6] Experimental investigations of single and two-phase flow in a heated rod bundle
    Barthel, F.
    Franz, R.
    Hampel, U.
    KERNTECHNIK, 2013, 78 (01) : 60 - 67
  • [7] Development of a subchannel void sensor and two-phase flow measurement in 10 x 10 rod bundle
    Arai, Takahiro
    Furuya, Masahiro
    Kanai, Taizo
    Shirakawa, Kenetsu
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2012, 47 : 183 - 192
  • [8] Void fraction measurement of the air-water two-phase flow in the sub-channel of a rod bundle geometry based on an impedance meter
    Yu, Bin
    Zhou, Wenxiong
    Pan, Liangming
    Liu, Hang
    Ren, Quanyao
    Tu, Shengpan
    ANNALS OF NUCLEAR ENERGY, 2018, 115 : 480 - 486
  • [9] Application of electrical impedance on measurement of void fraction in two-phase flow
    Chang, Yu-Hsien
    Chen, Shao-Wen
    Chai, Min-Lun
    Lin, Hsiao-Jou
    Lee, Jin-Der
    Wang, Jong-Rong
    Shih, Chunkuan
    2018 7TH IEEE INTERNATIONAL SYMPOSIUM ON NEXT-GENERATION ELECTRONICS (ISNE), 2018, : 233 - 235
  • [10] The Measurement of Void Fraction of a Two-phase Flow in Vertical Riser Tubes
    Cai, Jiyong
    Chen, Tingkuan
    Ye, Qiang
    Reneng Dongli Gongcheng/Journal of Engineering for Thermal Energy and Power, 14 (01): : 30 - 33