WITHSTAND VOLTAGE CHARACTERISTICS OF INSULATOR STRING COVERED WITH SNOW OR ICE

被引:71
|
作者
MATSUDA, H [1 ]
KOMURO, H [1 ]
TAKASU, K [1 ]
机构
[1] CTR RES INST ELECT POWER IND,DEPT TRANSMISS & DISTRIBUT,HIGH VOLTAGE SECT,TOKYO,JAPAN
关键词
TRANSMISSION LINE; INSULATOR; INSULATION DESIGN; WITHSTAND VOLTAGE; SNOW-COVERING; ICE-COATING;
D O I
10.1109/61.85873
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes the results of an investigation into the withstand voltage characteristics of an insulator string covered with snow or ice and the application of these results to the insulation design and maintenance of a transmission line in a heavy snow area. It has become clear that the characteristics of withstand voltage were affected by the specific gravity of snow, the conductivity of water melted from snow, the height of snow and the ratio of snow-covered length. The withstand voltage was greatly reduced under snowing conditions.
引用
收藏
页码:1243 / 1250
页数:8
相关论文
共 50 条
  • [1] AC WITHSTAND VOLTAGE CHARACTERISTICS OF INSULATOR STRING COVERED WITH SNOW
    YASUI, M
    NAITO, K
    HASEGAWA, Y
    IEEE TRANSACTIONS ON POWER DELIVERY, 1988, 3 (02) : 828 - 838
  • [2] Role of air gaps on AC withstand voltage of an ice-covered insulator string
    Farzaneh, M.
    Volat, C.
    Zhang, J.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (06) : 1350 - 1357
  • [3] Effect of insulator diameter on AC flashover voltage of an ice-covered insulator string
    Farzaneh, M
    Zhang, J
    Volat, C
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (02) : 264 - 271
  • [4] UHV AC Y-type Insulator String Pollution Withstand Voltage Characteristics
    Nan Jing
    Huo Feng
    Li Jian
    Wan Xiaodong
    Xu Tao
    Li Jin
    Jia Ru
    Liu Qin
    Li Yaoqin
    2017 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE), 2017, : 607 - 609
  • [5] Maximum withstand voltage of artificial ice-covered insulators
    Jiang, XL
    Zhang, ZJ
    Sun, CX
    Shu, LC
    Sima, W
    PROCEEDINGS OF THE FOURTEENTH (2004) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 1, 2004, : 927 - 932
  • [6] Effect of Ice Shedding on Discharge Characteristics of an Ice-Covered Insulator String during AC Flashover
    Li, Xiangxin
    Zhou, Ming
    Luo, Yazhou
    Wang, Gang
    Jia, Lin
    ENERGIES, 2018, 11 (09)
  • [7] Analysis of the flashover process on ice-covered insulator string
    Xu, Zuo-Ming
    Xu, Tao
    Yao, Tao
    Liu, Yun-Peng
    Wan, Qi-Fa
    Chen, Yong
    Hu, Wei
    Cai, Lin
    Cheng, Lei
    Chen, Zhi-Wei
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (12): : 2924 - 2929
  • [8] Study of the Flashover Process on Ice-covered Insulator String
    Xu, Zuoming
    Wu, Xiong
    Chen, Yong
    Liu, Yunpeng
    Yao, Tao
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 186 - 191
  • [9] Study on Dynamic Flashover Model of Ice-covered Insulator String
    Xu, Zuoming
    Xu, Tao
    Hu, Wei
    Yao, Tao
    Wan, Xiaodong
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 28 - 31
  • [10] Effect of non-uniform pollution on the withstand characteristics of extra high voltage (EHV) suspension ceramic insulator string
    Sima, W.
    Yuan, T.
    Yang, Q.
    Xu, K.
    Sun, C.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2010, 4 (03) : 445 - 455