CONCENTRATION DIFFERENCES BETWEEN SERUM AND PLASMA OF THE ELEMENTS COBALT, IRON, MERCURY, RUBIDIUM, SELENIUM AND ZINC DETERMINED BY NEUTRON-ACTIVATION ANALYSIS

被引:32
|
作者
KASPEREK, K
KIEM, J
IYENGAR, GV
FEINENDEGEN, LE
机构
[1] Kernforsch. Anlag Julich GmbH, D-5170 Julich, Germany
关键词
D O I
10.1016/0048-9697(81)90179-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The differences in concentrations of cesium, cobalt, iron, mercury, rubidium, selenium and zinc between serum and plasma were examined with the aid of instrumental neutron activation analysis. Eighty serum and plasma samples obtained from 13 donors were compared. Serum was prepared in plastic tubes immediately after clotting, and plasma was separated with heparin as anticoagulant. No significant differences in the concentrations of cesium, cobalt, mercury and selenium were observed. However, the concentrations of iron, rubidium and zinc were significantly higher in serum than in plasma. The average differences found for cesium, rubidium and zinc were far below that which can be expected from a complete, or considerable release of these elements from platelets which aggregate or disintegrate during the clotting process in preparing serum.