MODEL FOR RADIONUCLIDE EVALUATION OF LEFT-TO-RIGHT DUCTAL SHUNTS

被引:1
|
作者
ETEROVIC, D
DUJIC, Z
TOCILJ, J
POPOVIC, S
机构
[1] CLIN HOSP SPLIT,DIV PULM MED,SPLIT,CROATIA
[2] ZAGREB UNIV,SCH MED,DEPT PHYSIOL,SPLIT,CROATIA
[3] CLIN HOSP ZAGREB REBRO,DEPT NUCL MED,ZAGREB,CROATIA
来源
CLINICAL PHYSIOLOGY | 1994年 / 14卷 / 01期
关键词
PATENT DUCTUS ARTERIOSUS (PDA); FIRST-PASS RADIOANGIOGRAPHY; RADIOINDICATOR KINETICS; PULMONARY CIRCULATION;
D O I
10.1111/j.1475-097X.1994.tb00493.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A model for radionuclide evaluation of left-to-right ductal shunts was designed. It was a generalization of the standard Maltz-Treves method, accounting for the possibility that distribution of the shunt flow between the two lungs differs from that in the right ventricular (RV) output (F-s). This yields a new formulation in which the ratio of ductal now to pulmonary flow (F-d/F-p) equals a weighted average of F-d/F-p Obtained separately for the right lung (RL) and the left lung (LL), i.e. F-d/F-p=R(F-d/FpP)(RL)+(1-R) (F-d/F-p)(LL); where R is the fraction of the RV output going to the right lung. Separate shunt-flow ratios can be obtained by conventional analysis of the respective lung radiohistogram, while R can be determined from the upslopes of these curves. Formulas were derived rigorously from basic principles, so that the ultimate clinical validity of the method depends on radioangiographic assessment of R, (F-d/F-p)(RL) and (F-d/F-p)(LL). Due to asymmetry of flows there is no true referent method for patients with ductal shunts. Therefore a simulation study, using quasi-real data, was utilized, yielding satisfactory performances of the algorithm: (F-p/F-s)(calculated)=0.92 (F-p/F-s)(simulated)+0.15 (r=0.878).
引用
收藏
页码:87 / 101
页数:15
相关论文
共 50 条
  • [1] RADIONUCLIDE DETECTION OF LEFT-TO-RIGHT INTRACARDIAC SHUNTS
    JONES, RH
    ANDERSON, PA
    GOODRICH, JK
    SABISTON, DC
    JOURNAL OF NUCLEAR MEDICINE, 1971, 12 (06) : 370 - &
  • [2] RADIONUCLIDE DETECTION OF LEFT-TO-RIGHT CARDIAC SHUNTS
    ALAZRAKI, NP
    CALIFORNIA MEDICINE, 1971, 115 (02): : 71 - &
  • [3] QUANTITATION OF LEFT-TO-RIGHT CARDIAC SHUNTS WITH RADIONUCLIDE ANGIOGRAPHY
    ANDERSON, PA
    JONES, RH
    SABISTON, DC
    CIRCULATION, 1974, 49 (03) : 512 - 516
  • [4] RADIONUCLIDE QUANTITATION OF LEFT-TO-RIGHT CARDIAC SHUNTS IN CHILDREN
    MCILVEEN, BM
    HOSCHL, R
    MURRAY, IPC
    MCCREDIE, RM
    CHIDIAC, P
    MARRIOTT, D
    BEVERIDGE, J
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1978, 8 (05): : 500 - 508
  • [5] QUANTIFICATION OF LEFT-TO-RIGHT SHUNTS BY RADIONUCLIDE ANGIOCARDIOGRAPHY IN CHILDREN
    MALTZ, DL
    TREVES, S
    JOURNAL OF NUCLEAR MEDICINE, 1972, 13 (10) : 787 - &
  • [6] EVALUATION OF LEFT-TO-RIGHT CARDIAC SHUNTS
    SELZER, A
    POPPER, RW
    MINTZ, F
    JOURNAL OF CARDIOVASCULAR SURGERY, 1964, 5 (04): : 285 - &
  • [7] Detection of small left-to-right cardiac shunts by radionuclide angiocardiography
    Stanicic, A
    Jakl, R
    Ivancevic, D
    Popovic, S
    Milas, Z
    Capkun, V
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1110 - 1110
  • [8] DECONVOLUTION ANALYSIS IN RADIONUCLIDE QUANTITATION OF LEFT-TO-RIGHT CARDIAC SHUNTS
    ALDERSON, PO
    DOUGLASS, KH
    MENDENHALL, KG
    GUADIANI, VA
    WATSON, DC
    LINKS, JM
    WAGNER, HN
    JOURNAL OF NUCLEAR MEDICINE, 1979, 20 (06) : 502 - 506
  • [9] QUANTITATIVE RADIONUCLIDE ANGIOCARDIOGRAPHY FOR LEFT-TO-RIGHT CARDIAC SHUNTS IN CHILDREN
    SMALLHORN, JF
    ADAMS, APS
    GOLDBLATT, E
    SAVAGE, JP
    PEDIATRIC CARDIOLOGY, 1982, 3 (01) : 1 - 5
  • [10] THE CLINICAL UTILITY OF RADIONUCLIDE QUANTITATION OF LEFT-TO-RIGHT CARDIAC SHUNTS IN CHILDREN
    MCILVEEN, BM
    MURRAY, IPC
    GILES, R
    MOLK, GH
    SCARF, C
    MCCREDIE, RM
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1981, 11 (04): : 440 - 440