A new free-hand pedicle screw placement technique with reference to the supraspinal ligament

被引:0
|
作者
Li, Juming [1 ]
Zhao, Hong [1 ]
Xie, Hao [1 ]
Yu, Lipeng [1 ]
Wei, Jifu [1 ]
Zong, Min [2 ]
Chen, Feng [3 ]
Zhu, Ziqiang [1 ]
Zhang, Ning [1 ]
Cao, Xiaojian [1 ]
机构
[1] Nanjing Med Univ, Affiliated Hosp 1, Dept Orthopaed, 300 Guangzhou Rd, Nanjing 210029, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Affiliated Hosp 1, Dept Radiol, Nanjing 210029, Jiangsu, Peoples R China
[3] Nanjing Med Univ, Dept Stat, Nanjing 210029, Jiangsu, Peoples R China
来源
JOURNAL OF BIOMEDICAL RESEARCH | 2014年 / 28卷 / 01期
关键词
spine fracture; pedicle screw placement; radiation exposure; supraspinal ligament; anatomy reference;
D O I
10.7555/JBR.27.20130051
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
We sought to compare the safety and accuracy of a new free-hand pedicle screw placement technique to that of the conventional technique. One hundred fifty-three consecutive adult patients with simple fracture in the thoracic or/and lumbar spine were alternately assigned to either the new free-hand or the conventional group. In the new free-hand technique group, preoperative computerized tomography (CT) images were used to calculate the targeted medial-lateral angle of each pedicle trajectory and the pedicle screw was inserted perpendicular to the corresponding supraspinal ligament. In the conventional technique group, the medial-lateral and cranial-caudal angle of each pedicle trajectory was determined by intraoperatively under fluoroscopic guidance. The accuracy rate of pedicle screw placement, the time of intraoperative fluoroscopy, the operating time and the amount of blood loss during operation were respectively compared. All screws were analyzed by using intraoperative radiographs, intraoperative triggered electromyography (EMG) monitoring data, postoperative CT data and clinical outcomes. The accuracy rate of pedicle screw placement in the new free-hand technique group and the conventional technique group was 96.3% and 94.2% (P < 0.05), respectively. The intraoperative fluoroscopy time of the new technique group was less than that of the conventional technique group (5.37 seconds vs. 8.79 seconds, P < 0.05). However, there was no statistical difference in the operating time and the amount of blood loss during operation (P > 0.05). Pedicle screw placement with the free-hand technique which keeps the screw perpendicular to the supraspinal ligament is an accurate, reliable and safe technique to treat simple fracture in the thoracic or lumbar spine.
引用
收藏
页码:64 / 70
页数:7
相关论文
共 50 条
  • [1] A new free-hand pedicle screw placement technique with reference to the supraspinal ligament
    Juming Li
    Hong Zhao
    Hao Xie
    Lipeng Yu
    Jifu Wei
    Min Zong
    Feng Chen
    Ziqiang Zhu
    Ning Zhang
    Xiaojian Cao
    The Journal of Biomedical Research, 2014, 28 (01) : 64 - 70
  • [2] Thoracic pedicle screw placement: Free-hand technique
    Kim, YJJ
    Lenke, LG
    NEUROLOGY INDIA, 2005, 53 (04) : 512 - 519
  • [3] Accuracy and safety of pedicle screw placement in neuromuscular scoliosis with free-hand technique
    Modi, Hitesh N.
    Suh, Seung Woo
    Fernandez, Harry
    Yang, Jae Hyuk
    Song, Hae-Ryong
    EUROPEAN SPINE JOURNAL, 2008, 17 (12) : 1686 - 1696
  • [4] Accuracy and safety of pedicle screw placement in neuromuscular scoliosis with free-hand technique
    Hitesh N. Modi
    Seung Woo Suh
    Harry Fernandez
    Jae Hyuk Yang
    Hae-Ryong Song
    European Spine Journal, 2008, 17 : 1686 - 1696
  • [5] The "slide technique"-a novel free-hand method of subaxial cervical pedicle screw placement
    Liu, Bin
    Liu, Xiangyang
    Shen, Xiongjie
    Wang, Guoping
    Chen, Yixin
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [6] The “slide technique”—a novel free-hand method of subaxial cervical pedicle screw placement
    Bin Liu
    Xiangyang Liu
    Xiongjie Shen
    Guoping Wang
    Yixin Chen
    BMC Musculoskeletal Disorders, 21
  • [7] Validity of a Novel Free-Hand Pedicle Screw Placement Training Tool
    Mendelis, Joseph R.
    Gomez, Jaime A.
    Lo, Yungtai
    Hanstein, Regina
    Levy, I. Martin
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (04) : E172 - E180
  • [8] Sagittal orientation and uniform entry for thoracic pedicle screw placement with free-hand technique: A retrospective study on 382 pedicle screws
    Gokcen, H. Bahadir
    Erdogan, Sinan
    Ozturk, Sidar
    Gumussuyu, Gurkan
    Bayram, Irem
    Ozturk, Cagatay
    INTERNATIONAL JOURNAL OF SURGERY, 2018, 51 : 83 - 88
  • [9] A Novel Free-hand Technique of Pedicle Screw Placement in the Lumbar Spine: Accuracy Evaluation and Preliminary Clinical Results
    Jiang, Weiqi
    Leng, Ao
    Meng, Lingzhi
    Long, Zuoyao
    Long, Yu
    Wang, Qi
    ORTHOPAEDIC SURGERY, 2023, 15 (09) : 2260 - 2266
  • [10] Computed tomography assessment of lateral pedicle wall perforation by free-hand subaxial cervical pedicle screw placement
    Wang, Yingsong
    Xie, Jingming
    Yang, Zhendong
    Zhao, Zhi
    Zhang, Ying
    Li, Tao
    Liu, Luping
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (07) : 901 - 909