FOURIER CODED-APERTURE IMAGING IN NUCLEAR-MEDICINE

被引:0
|
作者
CHOU, C
机构
[1] Natl Yang Ming Medical Coll, Taipei
关键词
CODED APERTURE; GAMMA-RAY IMAGING; MOIRE; TOMOGRAPHY;
D O I
10.1049/ip-smt:19949767
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A Fourier aperture (FA) is composed of two sinusoidal gratings in contact. When the two gratings rotate on the same axis in equal angles but opposite directions a clear pattern of difference moire fringes is formed, the moire frequency depending on the angle between the two gratings. This aperture of moire fringes is used as a variable frequency grating which is able to scan the object spectrum in the frequency domain. The summation-filtered back projection algorithm with three different apodising functions was introduced in the reconstruction. A Tc-99m gamma ray source and a 1 in-diameter NaI scintillation detector were used in the experiment. The thyroid phantom images showed that spatial resolution of FA agrees with the theoretical prediction. Three dimensional image capability is also discussed. The matrix inversion algorithm was used in the computer simulation of 3-D images. Although the depth resolution of a FA is limited by the restricted view angle of the detector, two plane objects free from noise at different depths were reconstructed.
引用
收藏
页码:179 / 184
页数:6
相关论文
共 50 条
  • [1] CODED-APERTURE IMAGING IN NUCLEAR-MEDICINE
    SMITH, WE
    BARRETT, HH
    AARSVOLD, JN
    VISUAL INFORMATION PROCESSING FOR TELEVISION AND TELEROBOTICS, 1989, 3053 : 33 - 45
  • [2] FOURIER CODED APERTURE IMAGING IN NUCLEAR-MEDICINE
    CHOU, C
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 454 : 457 - 464
  • [3] ADVANCED CODED-APERTURE IMAGING-SYSTEM FOR NUCLEAR-MEDICINE
    OHYAMA, N
    HONDA, T
    TSUJIUCHI, J
    MATUMOTO, T
    IINUMA, TA
    ISHIMATSU, K
    APPLIED OPTICS, 1983, 22 (22): : 3555 - 3561
  • [4] ANALOG DECONVOLUTION IN CODED-APERTURE IMAGING APPLIED TO NUCLEAR-MEDICINE
    BRUNOL, J
    FONROGET, Y
    LOWENTHAL, S
    OPTICA ACTA, 1978, 25 (02): : 113 - 124
  • [5] HYBRID CODED-APERTURE PINHOLE IMAGING-SYSTEM FOR NUCLEAR-MEDICINE
    ERVIN, A
    BARRETT, HH
    GINDI, GR
    PAXMAN, RG
    GMITRO, AF
    GILES, CL
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1982, 72 (12) : 1803 - 1803
  • [6] ATTAINMENT OF 3-D IMAGES IN NUCLEAR-MEDICINE BY CODED-APERTURE DEVICES
    LEFKOPOULOS, D
    DANET, B
    GUILHEM, JB
    MORUCCI, JP
    GUIRAUD, R
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 312 : 188 - 194
  • [7] COMPARISON OF TECHNIQUES FOR STATIONARY CODED APERTURE IMAGING IN NUCLEAR-MEDICINE
    FLEMING, JS
    GODDARD, BA
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1982, 20 (01) : 7 - 11
  • [8] SMALL-SIGNAL SUPPRESSION IN CODED APERTURE IMAGING IN NUCLEAR-MEDICINE
    HOULE, S
    JOY, MLG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (01) : 369 - 373
  • [9] IMAGING WITH CODED-APERTURE MASKS
    SKINNER, GK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 221 (01): : 33 - 40
  • [10] CODED-APERTURE IMAGING OF THE HEART
    ROGERS, WL
    KORAL, KF
    MAYANS, R
    LEONARD, PF
    THRALL, JH
    BRADY, TJ
    KEYES, JW
    JOURNAL OF NUCLEAR MEDICINE, 1980, 21 (04) : 371 - 378