A HIGH-REPETITION-RATE, PICOSECOND HARD X-RAY SYSTEM, AND ITS APPLICATION TO TIME-RESOLVED X-RAY-DIFFRACTION

被引:41
|
作者
ANDERSON, T [1 ]
TOMOV, IV [1 ]
RENTZEPIS, PM [1 ]
机构
[1] UNIV CALIF IRVINE,DEPT CHEM,IRVINE,CA 92717
来源
JOURNAL OF CHEMICAL PHYSICS | 1993年 / 99卷 / 02期
关键词
D O I
10.1063/1.465350
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A new technique for generation of hard x-ray picosecond pulses is presented. Excitation of a x-ray diode with 10 ps ultraviolet light pulses produces characteristic x-ray pulses with duration in the range of 10-100 ps at a repetition rate of 300 Hz. The x-ray pulses are synchronized with picosecond accuracy to the optical pulses of the laser system as well to other ultrafast phenomena. Results of picosecond time-resolved x-ray diffraction are reported.
引用
收藏
页码:869 / 875
页数:7
相关论文
共 50 条
  • [1] NANOSECOND HARD X-RAY SOURCE FOR TIME-RESOLVED X-RAY-DIFFRACTION STUDIES
    TOMOV, IV
    CHEN, P
    RENTZEPIS, PM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (11): : 5214 - 5217
  • [2] An incoherent sub-picosecond X-ray source for time-resolved X-ray-diffraction experiments
    Feurer, T
    Morak, A
    Uschmann, I
    Ziener, C
    Schwoerer, H
    Förster, E
    Sauerbrey, R
    APPLIED PHYSICS B-LASERS AND OPTICS, 2001, 72 (01): : 15 - 20
  • [3] An incoherent sub-picosecond X-ray source for time-resolved X-ray-diffraction experiments
    T. Feurer
    A. Morak
    I. Uschmann
    Ch. Ziener
    H. Schwoerer
    E. Förster
    R. Sauerbrey
    Applied Physics B, 2001, 72 : 15 - 20
  • [4] Development of high-repetition-rate X-ray chopper system for time-resolved measurements with synchrotron radiation
    Osawa, Hitoshi
    Kudo, Togo
    Kimura, Shigeru
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2017, 56 (04)
  • [5] Development of picosecond time-resolved X-ray absorption spectroscopy by high-repetition-rate laser pump/X-ray probe at Beijing Synchrotron Radiation Facility
    Wang, Hao
    Yu, Can
    Wei, Xu
    Gao, Zhenhua
    Xu, Guang-Lei
    Sun, Da-Rui
    Li, Zhenjie
    Zhou, Yangfan
    Li, Qiu-Ju
    Zhang, Bing-Bing
    Xu, Jin-Qiang
    Wang, Lin
    Zhang, Yan
    Tan, Ying-Lei
    Tao, Ye
    JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 : 667 - 673
  • [6] TIME-RESOLVED X-RAY-DIFFRACTION AND SPECTROSCOPY
    MILLS, DM
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C393 - C393
  • [7] Time-resolved X-ray diffraction
    Wark, J
    CONTEMPORARY PHYSICS, 1996, 37 (03) : 205 - 218
  • [8] PICOSECOND TIME-RESOLVED HARD X-RAY-DIFFRACTION FROM LASER-HEATED METALLIC CRYSTALS
    CHEN, P
    TOMOV, IV
    RENTZEPIS, PM
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1995, 42 (02) : 119 - 126
  • [9] TIME-RESOLVED X-RAY-DIFFRACTION STATION - X-RAY OPTICS, DETECTORS, AND DATA ACQUISITION
    TOWNSANDREWS, E
    BERRY, A
    BORDAS, J
    MANT, GR
    MURRAY, PK
    ROBERTS, K
    SUMNER, I
    WORGAN, JS
    LEWIS, R
    GABRIEL, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2346 - 2349
  • [10] Thermoelastic study of nanolayered structures using time-resolved X-ray diffraction at high repetition rate
    Navirian, H. A.
    Schick, D.
    Gaal, P.
    Leitenberger, W.
    Shayduk, R.
    Bargheer, M.