AN ANATOMIC STUDY OF THE EFFECTS OF DURAL PUNCTURE WITH DIFFERENT SPINAL NEEDLES

被引:0
|
作者
CELLENO, D
CATALANO, P
CAPOGNA, G
COSTANTINO, P
机构
关键词
ANATOMY; SPINAL DURA MATER; EQUIPMENT; SPINAL NEEDLES; COMPLICATIONS; DURAL PUNCTURE;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Objectives. The purpose of this study is to evaluate the effects of puncture of lumbar dura mater with needles of different sizes and with bevels of different shapes. Methods. After removal, the dura was punctured with different needles (22-, 25-, 27-, and 29-gauge Quincke, 24-gauge Sprotte, 22-gauge Whitacre, and 18-gauge Tuohy needles) and observed by stereomicroscope to examine the gross morphology. Histologic features were observed by light microscope using frozen and fixed samples stained with hematoxylin and eosin or specific methods (Masson and Weigert) to evidence elastic or collagen fibers. Results. Puncture hole size was proportional to the size of the needle used. Quincke type needles determined oval or ellipsoidal holes; pencil-point needles determined more rounded holes. Dural retraction determined a reduction of the holes in all cases. Histologic examination revealed an irregular border of the hole, with sectioned as well as compressed fibers. The pattern of compressed but not sectioned fibers was observed more frequently in the samples punctured by pencil-point needles. Conclusions. This study confirms that the arrangement of dural fibers is not as uniform as previously thought. Histologic findings confirm the current opinion that pencil-point needles may be less traumatic than Quincke-type needles. The direction of the bevel of the needle does not appear to have great importance in determining the shape of the hole.
引用
收藏
页码:218 / 221
页数:4
相关论文
共 50 条
  • [1] SPINAL NEEDLES, FLOW AND DURAL PUNCTURE
    LYONS, G
    ANAESTHESIA, 1991, 46 (03) : 236 - 236
  • [2] COMPARISON OF THE FORCE REQUIRED FOR DURAL PUNCTURE WITH DIFFERENT SPINAL NEEDLES AND SUBSEQUENT LEAKAGE OF CEREBROSPINAL-FLUID
    WESTBROOK, JL
    UNCLES, DR
    TODD, B
    SITZMAN, BT
    CARRIE, LES
    ANESTHESIA AND ANALGESIA, 1994, 79 (04): : 769 - 772
  • [3] COMPARISON OF SIZE OF TWO SPINAL NEEDLES IN POST-DURAL PUNCTURE HEADACHE: A RETROSPECTIVE STUDY
    Bajwa, Baljit Singh
    Cheema, H. K.
    Kaur, Kulbir
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (100): : 16499 - 16501
  • [4] Recognition and differentiation of dural puncture click sensation: A subjective and objective prospective study of dural puncture forces using fine-gauge spinal needles
    Utsumi, Isao
    Hascilowicz, Tomasz
    Omi, Sachiko
    PLOS ONE, 2021, 16 (07):
  • [5] The effect of changing pressures on dural puncture and leak with various spinal needles on an in vitro model
    Apan, A
    Uz, A
    Ugur, HC
    Tekdemir, I
    JOURNAL OF CLINICAL NEUROSCIENCE, 2002, 9 (06) : 677 - 679
  • [6] In vitro investigation of cerebrospinal fluid leakage after dural puncture with various spinal needles
    Holst, D
    Möllmann, M
    Ebel, C
    Hausman, R
    Wendt, M
    ANESTHESIA AND ANALGESIA, 1998, 87 (06): : 1331 - 1335
  • [7] STERILIZING SPINAL PUNCTURE NEEDLES IN OIL
    不详
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1945, 127 (16): : 1088 - 1088
  • [8] A detachable grip for spinal puncture needles
    Eve, FC
    BRITISH MEDICAL JOURNAL, 1937, 1937 : 1073 - 1073
  • [9] RANDOMIZED CONTROLLED STUDY FOR POST DURAL PUNCTURE HEADACHE COMPARING WITH 25 GUAGE QUINCKE AND WHITACRE SPINAL NEEDLES IN OBSTETRIC PATIENTS
    Veeresham, Madupathy
    Venkateshwarlu, G.
    Prasuna, Jala
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (75): : 12967 - 12984
  • [10] Are atraumatic spinal needles as efficient as traumatic needles for lumbar puncture?
    Pelzer, N.
    Vandersteene, J.
    Bekooij, T. J. S.
    Schoonman, G. G.
    Wirtz, P. W.
    Vanopdenbosch, L. J.
    Koppen, H.
    NEUROLOGICAL SCIENCES, 2014, 35 (12) : 1997 - 1999