AN INDIFFERENCE POINT FOR ELECTRICAL-IMPEDANCE IN HUMANS

被引:25
|
作者
PERKO, G
PAYNE, G
SECHER, NH
机构
[1] Department of Anaesthesia, Rigshospitalet, University of Copenhagen
来源
ACTA PHYSIOLOGICA SCANDINAVICA | 1993年 / 148卷 / 02期
关键词
HEART RATE; VOLUME DISTRIBUTION;
D O I
10.1111/j.1748-1716.1993.tb09541.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Regional electrical impedance was used over eight sections of the human body (two thoracic; one abdominal, two thigh; two around the knee; and one lower leg) to determine the volume indifference point during passive head-up tilt in eight subjects. Head-up tilt was performed in 10-degrees increments from 0-degrees to 60-degrees over 6 min. Electrical impedance increased over the thorax in proportion to the head-up tilt angle, while abdominal impedance did not change significantly, and over the thigh and the lower leg it decreased with increasing head-up tilt angle. No change in electrical impedance was noted just above the knee, and electrical impedance just below the knee decreased only marginally. Results demonstrate minimal fluid accumulation around the knee during head-up tilt. Furthermore, in humans the electrical impedance and therefore probably the volume indifference point is positioned between the umbilicus and crista iliaca.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 50 条
  • [1] The venous pump does not affect the indifference point for electrical impedance in humans
    Perko, G
    Tilgreen, R
    Secher, NH
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1995, 72 (1-2): : 179 - 182
  • [2] NONINVASIVE PULMONARY MONITORING WITH TRANSTHORACIC ELECTRICAL-IMPEDANCE IN HUMANS
    BOOKE, M
    WENDT, M
    LAWIN, P
    ANESTHESIOLOGY, 1994, 81 (3A) : A535 - A535
  • [3] ELECTRICAL-IMPEDANCE IMAGING
    SEAGAR, AD
    BARBER, DC
    BROWN, BH
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1987, 134 (02): : 201 - 210
  • [4] ELECTRICAL-IMPEDANCE TOMOGRAPHY
    不详
    SEMAINE DES HOPITAUX, 1993, 69 (28): : 855 - 855
  • [5] ELECTRICAL-IMPEDANCE TOMOGRAPHY - THE CONSTRUCTION AND APPLICATION TO PHYSIOLOGICAL MEASUREMENT OF ELECTRICAL-IMPEDANCE IMAGES
    BROWN, BH
    BARBER, DC
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1987, 13 (02) : 69 - 75
  • [6] ELECTRICAL SAFETY FOR AN ELECTRICAL-IMPEDANCE TOMOGRAPH
    GHAHARY, A
    WEBSTER, JG
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 461 - 462
  • [7] ELECTRICAL-IMPEDANCE IMAGING OF THE THORAX
    KIM, Y
    WEBSTER, JG
    TOMPKINS, WJ
    JOURNAL OF MICROWAVE POWER AND ELECTROMAGNETIC ENERGY, 1983, 18 (03) : 245 - 257
  • [8] ELECTRICAL-IMPEDANCE OF ELECTRODIALYSIS MEMBRANES
    HERRMANN, CC
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1983, 130 (03) : C113 - C113
  • [9] MEASUREMENT OF TRANSTHORACIC ELECTRICAL-IMPEDANCE
    THOMAS, AN
    VOHRA, A
    POLLARD, BJ
    BRITISH JOURNAL OF ANAESTHESIA, 1991, 66 (06) : 733 - 734
  • [10] ELECTRICAL-IMPEDANCE TOMOGRAPHY - PREFACE
    BARBER, DC
    BROWN, BH
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 3 - 4