TEMPERATURE-MEASUREMENTS OF A HIGH-POWER MICROWAVE FEEDHORN WINDOW

被引:0
|
作者
HOPPE, DJ
PEREZ, RM
GLAZER, SD
机构
[1] Jet Propulsion Laboratory, Pasadena
关键词
Bessel Function - Fourier Transform Infrared Spectrometer - Infrared Radiometer - Microwave Feedhorn Window;
D O I
10.1109/19.106280
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Temperature measurements of a high-power microwave feedhorn window during transmitter operation at 365-kW CW and 8.5 GHz were made using an imaging infrared radiometer. The window under investigation was constructed of HTP-6, a high thermal performance material developed to shield the shuttle orbiter from the heat of reentry. The measurement technique is described and experimental results are presented. © 1990 IEEE
引用
收藏
页码:501 / 503
页数:3
相关论文
共 50 条
  • [1] MICROBENDING OPTOELECTRONIC SENSOR FOR ONLINE TEMPERATURE-MEASUREMENTS IN HIGH-POWER ELECTRICAL SYSTEMS
    CUTOLO, A
    GALLO, M
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER ENGINEERING, 1991, 1 (05): : 281 - 287
  • [2] Sapphire Based High-Power Microwave Window
    Nayek, Narugopal
    Subhadra, K.
    Kandpal, Manoj
    Majumdar, Arijit
    Chatterjee, Sayan
    Nainwad, C. S.
    Krishnan, R.
    Das, Subrata
    INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN MICROWAVE THEORY AND APPLICATIONS, PROCEEDINGS, 2008, : 598 - +
  • [3] Multiphysics Design of High-Power Microwave Vacuum Window
    Marrese F.
    Valletti L.
    Fantauzzi S.
    Leggieri A.
    Behtouei M.
    Spataro B.
    Di Paolo F.
    Journal of Microwaves, Optoelectronics and Electromagnetic Applications, 2022, 21 (01) : 157 - 170
  • [4] HIGH-POWER MICROWAVE WINDOW FOR REACTIVE PLASMA PRODUCTION
    SAKAMOTO, Y
    KOKAI, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (9A): : 3985 - 3986
  • [6] Microwave magnetic field effects on high-power microwave window breakdown
    Hemmert, D
    Neuber, AA
    Dickens, J
    Krompholz, H
    Hatfield, LL
    Kristiansen, M
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2000, 28 (03) : 472 - 477
  • [7] Research on calorimeter for high-power microwave measurements
    Ye, Hu
    Ning, Hui
    Yang, Wensen
    Tian, Yanmin
    Xiong, Zhengfeng
    Yang, Meng
    Yan, Feng
    Cui, Xinhong
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (12):
  • [8] FACTORS AFFECTING TEMPERATURE-MEASUREMENTS IN MICROWAVE THERMOGRAPHY
    LAND, DV
    JOURNAL OF PHOTOGRAPHIC SCIENCE, 1985, 33 (06): : 230 - 230
  • [9] A HIGH-DENSITY BERYLLIUM OXIDE WINDOW FOR HIGH-POWER MICROWAVE TRANSMISSION
    PEARSALL, CS
    MILLER, JD
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1963, 110 (08) : C192 - C192
  • [10] Ultrafast high-power microwave window breakdown: Nonlinear and postpulse effects
    Chang, C.
    Verboncoeur, J.
    Guo, M. N.
    Zhu, M.
    Song, W.
    Li, S.
    Chen, C. H.
    Bai, X. C.
    Xie, J. L.
    PHYSICAL REVIEW E, 2014, 90 (06):