QUANTITATIVE RADIONUCLIDE LEAKAGE MONITORING DURING ISOLATED LIMB PERFUSION

被引:0
|
作者
SPRENGER, HJ
MARKWARDT, J
SCHLAG, PM
机构
[1] FREE UNIV BERLIN,KLINIKUM RUDOLF VIRCHOW,ROBERT ROSSLE KLIN ONKOL,CHIRURG & CHIRURG ONKOL ABT,D-13122 BERLIN,GERMANY
[2] MAX DELBRUCK CTR MOLEC MED,BERLIN,GERMANY
关键词
PERFUSION; EXTREMITY; CHEMOTHERAPY; LEAKAGE; RADIONUCLIDE;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In order to reduce side effects of high-dose chemotherapy the penetration of the cytostatic substances into the main circulation should be prevented or limited. An efficient procedure for checking the leakage is generally based on the addition of a radionuclide to the perfusate. By scintillation probes the distribution of this radionuclide in the body of the patient is checked. A method is presented which continuously calculates the actual volume of the fluid which is penetrating into the main circulation during the perfusion. The values of momentary and cumulative volume crossover enables the surgical oncologist to detect a leakage readily and reliably and may be the basis for measures of confining it.
引用
收藏
页码:248 / 253
页数:6
相关论文
共 50 条
  • [1] Leakage Monitoring during Isolated Limb Perfusion
    Vidmar, S.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S486 - S486
  • [2] Radionuclide leakage monitoring during hyperthermic isolated limb perfusion for treatment of local melanoma metastasis in an extremity
    Paulsen, Ida F.
    Chakera, Annette Hougaard
    Schmidt, Grethe
    Drejoe, Jennifer
    Klyver, Helle
    Oturai, Peter S.
    Hesse, Birger
    Drzewiecki, Krystztof
    Mortensen, Jann
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2015, 35 (04) : 301 - 305
  • [3] A New Algorithm for the Continuous Quantitative Monitoring of Leakage during Chemotherapeutic Limb Perfusion
    Wierts, R.
    de Jong, J. R.
    Lazarenko, S. V.
    Willemsen, A. T. M.
    Paans, A. M. J.
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4108 - 4110
  • [4] SYSTEMIC LEAKAGE DURING ISOLATED LIMB PERFUSION FOR MELANOMA
    KLAASE, JM
    KROON, BBR
    VANGEEL, AN
    EGGERMONT, AMM
    FRANKLIN, HR
    [J]. BRITISH JOURNAL OF SURGERY, 1993, 80 (09) : 1124 - 1126
  • [5] Monitoring leakage during isolated hepatic perfusion
    Lindner, P
    [J]. ISOLATED LIVER PERFUSION FOR HEPATIC TUMORS, 1998, 147 : 51 - 55
  • [6] Characteristics of a new system for monitoring the leakage factor during regional hyperthermic isolated limb perfusion
    Wierts, Roel
    de Jong, Johan R.
    Lazarenko, Sergiy V.
    Paans, Anne M.
    Dierckx, Rudi A.
    Willemsen, Antoon M.
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (09) : 853 - 862
  • [7] A simplified procedure for continuous intraoperative external monitoring of systemic leakage during isolated limb perfusion
    Casara, D
    Rubello, D
    Pilati, PL
    Scalerta, R
    Foletto, M
    Rossi, CR
    [J]. TUMORI, 2002, 88 (03) : S61 - S63
  • [8] A new simplified technique for continuous monitoring of systemic leakage during isolated limb perfusion.
    Casara, D
    Rubello, D
    Pilati, P
    Foletto, M
    Rossi, CR
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 309P - 309P
  • [9] Continuous leakage measurement during hyperthermic isolated limb perfusion
    Daryanani, D
    Komdeur, R
    Ter Veen, J
    Nijhuis, PH
    Piers, DA
    Hoekstra, HJ
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2001, 8 (07) : 566 - 572
  • [10] Continuous Leakage Measurement During Hyperthermic Isolated Limb Perfusion
    D. Daryanani
    R. Komdeur
    J. Ter Veen
    P. H. Nijhuis
    D. A. Piers
    H. J. Hoekstra
    [J]. Annals of Surgical Oncology, 2001, 8 : 566 - 572