Distance stereotesting using vision test charts for intermittent exotropia

被引:5
|
作者
Nishikawa, Noriko [1 ]
Ishiko, Satoshi [2 ,3 ]
Yamaga, Ikuko [1 ]
Sato, Miho [4 ]
Yoshida, Akitoshi [1 ]
机构
[1] Asahikawa Med Univ, Dept Ophthalmol, Asahikawa, Hokkaido 0788510, Japan
[2] Asahikawa Med Univ, Dept Med, 2-1-1 Midorigaoka, Asahikawa, Hokkaido 0788510, Japan
[3] Asahikawa Med Univ, Engn Combined Res Inst, Asahikawa, Hokkaido 0788510, Japan
[4] Hamamatsu Univ Sch Med, Dept Ophthalmol, Hamamatsu, Shizuoka 4313192, Japan
来源
CLINICAL OPHTHALMOLOGY | 2015年 / 9卷
关键词
distance stereoacuity; System Chart SC-1600 Pola; Distance Randot Stereotest; Newcastle Control Score;
D O I
10.2147/OPTH.S89727
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the role of distance stereoacuity using the System Chart SC-1600 Pola (SC) to evaluate intermittent exotropia (IXT). Methods: Stereoacuity testing was performed in 28 children with IXT and 25 age-matched control subjects using the SC test, the distance Randot stereotest for distance, and the Titmus stereotest for near stereoacuity. Ocular alignment control was defined using the revised Newcastle Control Score (NCS). The correlations between the stereotests and NCS were evaluated using Spearman's correlation test. Results: Distance stereoacuity was better in both groups when using the SC test than when using the distance Randot stereotest (median: patients with IXT, 90 arcsec and 400 arcsec; control, 60 arcsec and 100 arcsec; P<0.001 for both comparisons). The two test scores were not correlated in either group (IXT: r(s)=-0.003, P=0.99; control: r(s)=0.37, P=0.07). A positive correlation was found between the distance NCS and SC test scores (r(s)=0.49, P=0.004) and the total NCS and SC test scores (r(s)=0.49, P=0.004). However, no correlation was observed between any NCS and the distance Randot stereotest or Titmus stereotest scores. Conclusion: Stereoacuity, as measured by the SC test, may be an objective measure of IXT control.
引用
收藏
页码:1557 / 1562
页数:6
相关论文
共 50 条
  • [1] Distance stereoacuity in intermittent exotropia
    Hatt, S. R.
    Haggerty, H.
    Buck, D.
    Adams, W.
    Strong, N. P.
    Clarke, M. P.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (02) : 219 - 221
  • [2] TEST CHARTS FOR DISTANCE PREFERRED FOR LOW-VISION
    FONDA, G
    [J]. ANNALS OF OPHTHALMOLOGY, 1987, 19 (05): : 178 - 180
  • [3] Interventions for intermittent distance exotropia: review
    Gnanaraj, L
    Richardson, SR
    [J]. EYE, 2005, 19 (06) : 617 - 621
  • [4] Interventions for intermittent distance exotropia: review
    L Gnanaraj
    S R Richardson
    [J]. Eye, 2005, 19 : 617 - 621
  • [5] Distance/near differences in intermittent exotropia
    Kushner, BJ
    Morton, GV
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (04) : 478 - 486
  • [6] Clinical Usefulness of a Computerized Vision Chart for Distance Stereoacuity Assessment in Children with Intermittent Exotropia
    Ayyildiz, Onder
    Yalinbas, Duygu
    Ceylan, Osman Melih
    Mutlu, Fatih Mehmet
    [J]. SEMINARS IN OPHTHALMOLOGY, 2021, 36 (1-2) : 41 - 45
  • [7] Photophobia measurement in intermittent exotropia using the contrast sensitivity test
    Chung, Seung Ah
    Rhiu, Soolienah
    Han, Seung
    Lee, Jong Bok
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (05) : 1405 - 1411
  • [8] Vision therapy for intermittent exotropia: A case series
    Ma, Martin Ming-Leung
    Kang, Ying
    Chen, Chao
    Su, Cuiyun
    Tian, Zhen
    Le, Meihua
    [J]. JOURNAL OF OPTOMETRY, 2021, 14 (03) : 247 - 253
  • [9] DISTANCE STEREOACUITY - ASSESSING CONTROL IN INTERMITTENT EXOTROPIA
    STATHACOPOULOS, RA
    ROSENBAUM, AL
    ZANONI, D
    STAGER, DR
    MCCALL, LC
    ZIFFER, AJ
    EVERETT, M
    [J]. OPHTHALMOLOGY, 1993, 100 (04) : 495 - 500
  • [10] Does Distance Stereoacuity Deteriorate in Intermittent Exotropia?
    Leske, D. A.
    Hatt, S. R.
    Mohney, B. G.
    Brodsky, M. C.
    Yamada, T.
    Holmes, I. M.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)