Evaluation of the Cobas Core system for use in routine diagnosis of thyroid disorders

被引:0
|
作者
Langsteger, W [1 ]
Koltringer, P [1 ]
Eber, O [1 ]
Purstner, P [1 ]
机构
[1] GRAZ UNIV,DEPT GYNECOL & OBSTET,GRAZ,AUSTRIA
关键词
Cobas Core EIA; RIA; in-vitro measurement; thyroid hormones; TBG; binding proteins; autoantibodies;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this clinical study was to evaluate the TSH, FT4, FT3, T3, and T4 assays designed for use on the Cobas Core Immunoassay Analyzer. Performance of these enzyme immunoassays (EIAs) was compared with well established and routinely used radioimmunoassays (RIA) or immunoradiometric assay (IRMA). In the first part of the study, the between-run and within-run data as well as the linearity of the Cobas Core assays was carried out, showing a very high precision; most coefficients of variation (CVs) were below 8%. In the second part of the study, serum samples from patients with different thyroid diseases were evaluated, and the results compared with those obtained by RIA or by IRMA. All results were highly comparable with the clinical aspects of all investigated thyroid disorders, and the data of TSH, FT4, T3 and T4 were completely in concordance with those assessed by RIA or IRMA methods; however, only the FT3 assays had a moderately correlation. In contrast to RIA methods, Cobas Core EIAs provided precise results in patients with thyroid hormone transport protein anomalies or T4/T3 autoantibodies; moreover, elevated serum concentrations of thyroxine binding globulin (TBG) did not affect measurement of total thyroid hormone concentrations.
引用
收藏
页码:113 / 120
页数:8
相关论文
共 50 条
  • [1] Routine evaluation in a psychotherapy service: The use of CORE System data
    Botella, Luis
    EUROPEAN JOURNAL OF PSYCHOTHERAPY & COUNSELLING, 2006, 8 (02) : 235 - 241
  • [2] EVALUATION OF COBAS FARA IN A ROUTINE LABORATORY
    SCHOLER, A
    PERSENICO, J
    KINDBEITER, JM
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1985, 23 (09): : 604 - 604
  • [3] THYROID TESTING USING THE COBAS(R) CORE IMMUNOASSAY SYSTEM - A MULTICENTER STUDY
    MICHOTEY, O
    DORR, R
    BOURDERONT, D
    GAYA, J
    RIVERA, F
    BENZ, R
    SCHMIDT, M
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1995, 33 (09): : 609 - 622
  • [4] System performance evaluation of the cobas t 711 and cobas t 511 coagulation analyzers in routine laboratory settings
    Kitchen, Steve
    de Maat, Moniek
    Nagler, Michael
    Jones, Robert
    Lowe, Anna
    Burden, John
    Groneberg, Kai
    Rozsnyai, Gergely
    BLOOD COAGULATION & FIBRINOLYSIS, 2020, 31 (07) : 459 - 468
  • [5] USE OF THE TSH TEST IN THE DIAGNOSIS OF THYROID DISORDERS
    JEFFERIES, WM
    LEVY, RP
    STORAASLI, JP
    RADIOLOGY, 1959, 73 (03) : 341 - 344
  • [6] USE OF RADIOACTIVE IODINE IN THE DIAGNOSIS OF THYROID DISORDERS
    GOOLDEN, AWG
    BRITISH MEDICAL BULLETIN, 1960, 16 (02) : 105 - 112
  • [7] EVALUATION OF A MULTIPHASIC APPROACH TO DIAGNOSIS OF THYROID DISORDERS
    FRANCO, J
    JOHNSON, J
    COPPLER, M
    KOVALESK.B
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1968, 50 (01) : 107 - &
  • [8] ROUTINE USE OF 132I IN DIAGNOSIS OF THYROID DISEASE
    HOBBS, JR
    MACLAGAN, NF
    BAYLISS, RIS
    LANCET, 1963, 1 (727): : 8 - +
  • [9] Evaluation of the COBAS® INTEGRA for routine lipid testing.
    Ritchie, JC
    Tuten, T
    Jerkunica, I
    Zhang, H
    Sgoutas, DS
    Mullins, RE
    CLINICAL CHEMISTRY, 1998, 44 : A78 - A79
  • [10] Evaluation of the COBAS Core II immunochemistry analyser
    Kotting, J
    Heinemann, G
    Salb, I
    MaierLenz, H
    JOURNAL OF AUTOMATIC CHEMISTRY, 1996, 18 (06): : 205 - 215