STABILITY OF SERUM PROSTATE-SPECIFIC ANTIGEN DETERMINATION ACROSS LABORATORY, ASSAY, AND STORAGE TIME

被引:25
|
作者
JACOBSEN, SJ
KLEE, GG
LILJA, H
WRIGHT, GL
OESTERLING, JE
机构
[1] MAYO CLIN & MAYO FDN,CLIN EPIDEMIOL SECT,ROCHESTER,MN 55905
[2] MAYO CLIN & MAYO FDN,DEPT LAB MED & PATHOL,ROCHESTER,MN 55905
[3] MAYO CLIN & MAYO FDN,DEPT UROL,ROCHESTER,MN 55905
[4] MAYO CLIN & MAYO FDN,DIV METAB & HEMATOL BIOCHEM,ROCHESTER,MN 55905
[5] LUND UNIV,MALMO GEN HOSP,DEPT CLIN CHEM,S-21401 MALMO,SWEDEN
[6] EASTERN VIRGINIA MED SCH,DEPT MICROBIOL & IMMUNOL,NORFOLK,VA 23501
[7] EASTERN VIRGINIA MED SCH,CTR UROL ONCOL,NORFOLK,VA 23501
关键词
D O I
10.1016/S0090-4295(99)80014-4
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives. To understand the comparability of serum prostate-specific antigen (PSA) determinations across assays and storage time. Methods. Serum PSA levels were determined for men aged 40 to 79 years from the clinical subset of the Olmsted County Study of Urinary Symptoms and Health Status Among Men on fresh samples and after a median of 32 months on banked samples, frozen at -70 degrees C. Baseline serum PSA levels were determined by Tandem-R PSA assay. Follow-up levels on the banked samples were determined by the IMx PSA assay and a repeat Tandem-R PSA assay in a different laboratory and by an immunofluorometric PSA assay at another site. Results. The median serum PSA level determined by Tandem-R assay at baseline was 1.0 ng/ml (25th percentile, 0.6; 75th percentile, 1.7). The distributions of determination made by follow-up Tandem-R, IMx, and immunofluorometric analyses were essentially identical. Overall, the assays were highly correlated. The correlations between the baseline serum PSA determination and repeated Tandem-R, IMx, and immunofluorometric determinations were 0.96, 0.96, and 0.97, respectively (all P <0.001). The median duration of frozen storage was 32 months (range, 26 to 39 months), and the correlations between baseline and follow-up determinations did not change when stratified by duration of storage. Conclusions. These data provide important reassurance about the use of serum PSA determinations obtained by different assays, in different laboratories, and in properly stored samples across time.
引用
收藏
页码:447 / 453
页数:7
相关论文
共 50 条
  • [1] ASSAY VARIABILITY IN SERUM PROSTATE-SPECIFIC ANTIGEN DETERMINATION
    BRAWER, MK
    DAUM, P
    PETTEWAY, JC
    WENER, MH
    [J]. PROSTATE, 1995, 27 (01): : 1 - 6
  • [2] DETERMINATION OF PROSTATE-SPECIFIC ANTIGEN IN SERUM BY IMMUNORADIOMETRIC ASSAY
    LINDSTEDT, G
    JACOBSSON, A
    LUNDBERG, PA
    HEDELIN, H
    PETTERSSON, S
    UNSGAARD, B
    [J]. CLINICAL CHEMISTRY, 1990, 36 (01) : 53 - 58
  • [3] Storage stability of prostate-specific antigen
    Hamm, M
    Semjonow, A
    Rathert, P
    [J]. AKTUELLE UROLOGIE, 1996, 27 (03) : 141 - 145
  • [4] MEASUREMENT OF SERUM PROSTATE-SPECIFIC ANTIGEN USING IMX PROSTATE-SPECIFIC ANTIGEN-ASSAY
    KLEE, GG
    DODGE, LA
    ZINCKE, H
    OESTERLING, JE
    [J]. JOURNAL OF UROLOGY, 1994, 151 (01): : 94 - 98
  • [5] SERUM PROSTATE-SPECIFIC ANTIGEN-ASSAY - AN UPDATE
    WU, JT
    [J]. WESTERN JOURNAL OF MEDICINE, 1995, 162 (05): : 447 - 448
  • [6] PROSTATE-SPECIFIC ANTIGEN - QUANTITATION IN SERUM BY IMMUNORADIOMETRIC ASSAY
    MYRTLE, JF
    SHACKELFORD, W
    BARTHOLOMEW, RM
    WAMPLER, J
    [J]. CLINICAL CHEMISTRY, 1983, 29 (06) : 1216 - 1216
  • [7] RAPID SEMIQUANTITATIVE ASSAY OF PROSTATE-SPECIFIC ANTIGEN IN SERUM
    CHOI, YH
    HONG, MS
    KANG, RJ
    KANG, J
    [J]. CLINICAL CHEMISTRY, 1994, 40 (09) : 1831 - 1832
  • [8] Stability of total prostate-specific antigen and free prostate-specific antigen after 10 years' storage
    Simanek, Vaclav
    Topolcan, Ondrej
    Karlikova, Marie
    Dolejsova, Olga
    Fuchsova, Radka
    Kinkorova, Judita
    Slouka, David
    Kucera, Radek
    [J]. INTERNATIONAL JOURNAL OF BIOLOGICAL MARKERS, 2018, 33 (04): : 463 - 466
  • [9] STORAGE-CONDITIONS FOR SERUM FOR ESTIMATING PROSTATE-SPECIFIC ANTIGEN
    SIMM, B
    GLEESON, M
    [J]. CLINICAL CHEMISTRY, 1991, 37 (01) : 113 - 114
  • [10] ABBOTT IMX(R) EVALUATED FOR ASSAY OF PROSTATE-SPECIFIC ANTIGEN IN SERUM
    DNISTRIAN, AM
    SCHWARTZ, MK
    SMITH, CA
    NISSELBAUM, JS
    FAIR, WR