摘要
Acoustic comfort in open-plan offices is a relatively recent research topic and some practices have not yet been consolidated. The goal in these spaces is to achieve good speech privacy at every workstation, reaching a high value of spatial decay of the sound pressure level. In case of refurbishment, a proper measurement of intelligibility criteria is needed, for example, in order to properly calibrate a numerical model or to plan acoustic treatments. This work compares different measurement techniques to evaluate the spatial distribution of intelligibility criteria. In situ measurements were done in an open-plan office used as a case study. Both omnidirectional and directional sound sources with different sound power levels were used, according, respectively, to ISO 3382-3:2012 and ITU-T P.51:1996. Furthermore, compensation algorithms were used in impulse response measurements in presence of Heating, Ventilation and Air Conditioning noise. The study shows, in a preliminary way, how different techniques and equipment can influence intelligibility criteria used in the open-plan office characterization. Results show that the indirect method of measuring Speech Transmission Index could not be used when the background level is high as the case study while the direct method returns good results.
引用
收藏
页码:111 / 122
页数:12
相关论文
共 50 条
  • [1] Prediction of the speech intelligibility index behind a single screen in an open-plan office
    Wang, C
    Bradley, JS
    APPLIED ACOUSTICS, 2002, 63 (08) : 867 - 883
  • [2] Evidence for the open-plan office
    Wong, Marcus
    OCCUPATIONAL MEDICINE-OXFORD, 2019, 69 (07): : 470 - 470
  • [3] DESIGNING AN OPEN-PLAN OFFICE
    LORIMER, AG
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1970, 48 (01): : 98 - &
  • [4] Open-Plan Offices: Comparison of Methods for Measuring Psychoacoustic Intelligibility Parameters
    Serrano-Ruiz, Maria P.
    Yarza-Acuna, Jose A.
    Martinez-Gomez, Erwin A. A.
    Ibarra-Mejia, Gabriel
    APPLIED SCIENCES-BASEL, 2023, 13 (15):
  • [5] OPEN-PLAN OFFICE, CONCEPTS AND ATTRIBUTES
    PROPST, RL
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1970, 47 (1P1): : 78 - &
  • [6] ACOUSTICAL ENVIRONMENT IN OPEN-PLAN OFFICE
    HARRIS, DA
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1976, 60 : S58 - S58
  • [7] OPEN-PLAN OFFICE LIGHTING.
    Orfield, Steven J.
    Lighting Design and Application: LD and A, 1987, 17 (07) : 7 - 19
  • [8] COMPUTATIONAL STUDIES OF SPEECH INTELLIGIBILITY IN OPEN-PLAN OFFICES
    Mikulski, Witold
    MEDYCYNA PRACY, 2019, 70 (03) : 327 - 342
  • [9] SOUND-ATTENUATION IN AN OPEN-PLAN OFFICE
    LERRO, JP
    DESIGN NEWS, 1979, 35 (10) : 30 - &
  • [10] ACOUSTICS IN OFFICE LANDSCAPE AND OPEN-PLAN SCHOOLS
    SULEWSKY, JE
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1970, 48 (01): : 99 - &