PROPORTIONAL-PLUS-INTEGRAL CONTROL OF EXPERIMENTAL OZONE CONCENTRATIONS IN A LARGE OPEN-TOP CHAMBER

被引:6
|
作者
DEAN, TJ
JOHNSON, JD
机构
来源
关键词
AIR QUALITY; OZONE; OPEN-TOP CHAMBERS; TREATMENT CONTROL;
D O I
10.1016/0960-1686(91)90152-W
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The main limitation in using a proportional controller to regulate experimental ozone concentrations is that proportional controllers generate zero output when the actual concentration equals the target concentration. Adding an integral controller to a proportional controller can potentially increase the controller can potentially increase the precision in regulating experimental ozone concentrations because the controller generates a constant output when the actual and target ozone concentration are equal. The realized precision of a proportional-plus-integral (PI) controller in regulating an ozone treatment in a large open-top chamber was assessed by analyzing hourly ratios of the ozone concentration inside a chamber and of the ambient bulk air (C(c):C(a)) from May to September 1989. The target C(c):C(a) ratio for this study was 3.0, and the actual ratio was deemed in control if it lay between 2.7 and 3.3 (3.0+/-10%). For 89 uninterrupted days of exposure, the median ozone ratio averaged 2.99 and was in control during the exposure period. The 90 percentile range of ozone ratios for each was also in control for all but the early and late hours of exposure. Comparing the precision of ozone control for a calm day and for a breezy day showed little difference, indicating that the PI controller successfully compensated for ambient-air ingression into the chamber. Implementation of a PI controller is described as well as strategies for dealing with the potential risk of overexposure by the integral controller.
引用
收藏
页码:1123 / 1126
页数:4
相关论文
共 35 条
  • [1] Proportional-plus-integral semiactive control using magnetorheological dampers
    Aguirre, N.
    Ikhouane, F.
    Rodellar, J.
    JOURNAL OF SOUND AND VIBRATION, 2011, 330 (10) : 2185 - 2200
  • [2] AN OPTIMAL PROPORTIONAL-PLUS-INTEGRAL TRACKING CONTROL LAW FOR AIRCRAFT APPLICATIONS
    SADEGHI, T
    WOZNY, M
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1984, 29 (09) : 827 - 829
  • [3] OPTIMAL PROPORTIONAL-PLUS-INTEGRAL/TRACKING CONTROL LAW FOR AIRCRAFT APPLICATIONS.
    Sadeghi, Tahm
    Wozny, Michael
    IEEE Transactions on Automatic Control, 1984, AC-29 (09): : 827 - 829
  • [4] POLE ASSIGNMENT USING PROPORTIONAL-PLUS-INTEGRAL OUTPUT-FEEDBACK CONTROL
    NOVINHIRBOD, S
    INTERNATIONAL JOURNAL OF CONTROL, 1979, 29 (06) : 1035 - 1046
  • [5] A proportional-plus-integral boundary control design for an unstable heat conduction system
    Cheng, Meng-Bi
    Su, Wu-Chung
    PROCEEDINGS OF THE 46TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-14, 2007, : 5267 - 5272
  • [6] DISPARITY IN OZONE RESPONSE OF BEAN-PLANTS GROWN IN A GREENHOUSE, GROWTH CHAMBER OR OPEN-TOP CHAMBER
    LEWIS, E
    BRENNAN, E
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1977, 27 (09): : 889 - 891
  • [7] OZONE AND BOTRYTIS INTERACTIONS IN ONION-LEAF DIEBACK - OPEN-TOP CHAMBER STUDIES
    WUKASCH, RT
    HOFSTRA, G
    PHYTOPATHOLOGY, 1977, 67 (09) : 1080 - 1084
  • [8] The open-top chamber impact on vapour pressure deficit and its consequences for stomatal ozone uptake
    Piikki, K.
    De Temmerman, L.
    Hoegy, P.
    Pleijel, H.
    ATMOSPHERIC ENVIRONMENT, 2008, 42 (26) : 6513 - 6522
  • [9] PHASEOLUS-VULGARIS AND OZONE - RESULTS FROM OPEN-TOP CHAMBER EXPERIMENTS IN FRANCE AND ENGLAND
    SANDERS, GE
    COLLS, JJ
    CLARK, AG
    GALAUP, S
    BONTE, J
    CANTUEL, J
    AGRICULTURE ECOSYSTEMS & ENVIRONMENT, 1992, 38 (1-2) : 31 - 40
  • [10] Interactive effects of elevated ozone plus carbon dioxide on duckweeds exposed in open-top chambers
    Bailey, S
    Rebbeck, J
    Loats, KV
    OHIO JOURNAL OF SCIENCE, 1999, 99 (02) : 19 - 25