LIPID HYDROPEROXIDE MEASUREMENT BY OXIDATION OF FE2+ IN THE PRESENCE OF XYLENOL ORANGE - COMPARISON WITH THE TBA ASSAY AND AN IODOMETRIC METHOD

被引:545
|
作者
JIANG, ZY [1 ]
WOOLLARD, ACS [1 ]
WOLFF, SP [1 ]
机构
[1] UNIV COLL & MIDDLESEX SCH MED,DEPT CLIN PHARMACOL,TOXICOL LAB,5 UNIV ST,LONDON WC1E 6JJ,ENGLAND
关键词
D O I
10.1007/BF02536169
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Study of the role of hydroperoxides and lipid peroxidation in disease requires simple and sensitive methods for direct hydroperoxide measurement. We report on a technique for measuring hydroperoxide which relies upon the rapid hydroperoxide-mediated oxidation of Fe2+ under acidic conditions. Fe3+ forms a chromophore with xylenol orange which absorbs strongly at 560 rum, yielding an apparent E560 (for H2O2, butyl hydroperoxide and cumene hydroperoxide) of 4.3 X 10(4) M-1 cm-1. The assay was validated in a study of liposomal lipid peroxidation and shown to give results comparable with those obtained by an iodometric method or by measuring conjugated dienes. The assay involving thiobarbituric acid, by comparison, underestimates lipid peroxidation and does not measure hydroperoxide per se.
引用
收藏
页码:853 / 856
页数:4
相关论文
共 8 条
  • [1] Spectrophotometric measurement of hydroperoxides at increased sensitivity by oxidation of Fe2+ in the presence of xylenol orange
    Deiana, L
    Carru, C
    Pes, G
    Tadolini, B
    [J]. FREE RADICAL RESEARCH, 1999, 31 (03) : 237 - 244
  • [2] MEASUREMENT OF PLASMA HYDROPEROXIDE CONCENTRATIONS BY THE FERROUS OXIDATION XYLENOL ORANGE ASSAY IN CONJUNCTION WITH TRIPHENYLPHOSPHINE
    NOUROOZZADEH, J
    TAJADDINISARMADI, J
    WOLFF, SP
    [J]. ANALYTICAL BIOCHEMISTRY, 1994, 220 (02) : 403 - 409
  • [3] FERROUS ION OXIDATION IN THE PRESENCE OF XYLENOL ORANGE FOR DETECTION OF LIPID HYDROPEROXIDE IN LOW-DENSITY-LIPOPROTEIN
    JIANG, ZY
    HUNT, JV
    WOLFF, SP
    [J]. ANALYTICAL BIOCHEMISTRY, 1992, 202 (02) : 384 - 389
  • [4] Measurement of Lipid Hydroperoxides by the Ferric-Xylenol Orange Method (2) Application to Lipoxygenase Assay
    Fukuzawa, Kenji
    Sano, Masumi
    Akai, Kaori
    Morishige, Junichi
    Tokumura, Akira
    Jisaka, Mituo
    [J]. JOURNAL OF NUTRITIONAL SCIENCE AND VITAMINOLOGY, 2009, 55 (01) : 92 - 98
  • [5] Lipid hydroperoxide determination in dark chicken meat through a ferrous oxidation-xylenol orange method
    Grau, A
    Codony, R
    Rafecas, M
    Barroeta, AC
    Guardiola, F
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (09) : 4136 - 4143
  • [6] Re-evaluation of the ferrous oxidation in xylenol orange assay for the measurement of plasma lipid hydroperoxides
    Södergren, E
    Nourooz-Zadeh, J
    Berglund, L
    Vessby, B
    [J]. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1998, 37 (03): : 137 - 146
  • [7] THE KINETICS OF OXYGEN-CONSUMPTION AND CHEMILUMINESCENCE IN THE COURSE OF LIPID OXIDATION IN THE PRESENCE OF FE2+ IONS
    OPEIDA, IA
    SHENDRIK, AN
    KACHURIN, IO
    NIKOLAEVSKII, AN
    KOVGAN, YA
    BOTVINKO, NM
    [J]. KINETICS AND CATALYSIS, 1994, 35 (01) : 31 - 36
  • [8] SPECTRAL CHARACTERIZATION OF LIPID-PEROXIDATION IN RABBIT LENS MEMBRANES INDUCED BY HYDROGEN-PEROXIDE IN THE PRESENCE OF FE2+/FE3+ CATIONS - A SITE-SPECIFIC CATALYZED OXIDATION