Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

被引:13
|
作者
Phelan, Michael P. [1 ]
Reineks, Edmunds Z. [2 ]
Hustey, Fredric M. [1 ]
Berriochoa, Jacob P. [4 ]
Podolsky, Seth R. [1 ]
Meldon, Stephen [1 ]
Schold, Jesse D. [3 ]
Chamberlin, Janelle [1 ]
Procop, Gary W. [2 ]
机构
[1] Cleveland Clin Hlth Syst, Emergency Serv Inst, 9500 Euclid Ave, Cleveland, OH 44195 USA
[2] Cleveland Clin Hlth Syst, Pathol & Lab Med Inst, Cleveland, OH 44195 USA
[3] Cleveland Clin Hlth Syst, Quantitat Hlth Sci, Cleveland, OH 44195 USA
[4] MetroHlth Med Ctr, Emergency Med Emergency Dept, Cleveland, OH 44109 USA
关键词
pneumatic tube; hemolysis; lab sample; emergency department;
D O I
10.5811/westjem.2016.6.29948
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods: The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest (R)) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results: During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%-14.6%). Conclusion: We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department.
引用
收藏
页码:557 / 560
页数:4
相关论文
共 50 条
  • [1] Hemolysis associated with pneumatic tube system transport for blood samples
    Kara, Hasan
    Bayir, Aysegul
    Ak, Ahmet
    Degirmenci, Selim
    Akinci, Murat
    Agacayak, Ahmet
    Marcil, Emine
    Azap, Melih
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2014, 30 (01) : 50 - 53
  • [2] Pneumatic tube transport system for blood samples: Evaluation of its effect on hemolysis
    Kapoula, G.
    Filntisis, I.
    Karampousli, E.
    Kalivas, M.
    Pagioulas, K.
    Parharidis, P.
    [J]. SCIENTIFIC CHRONICLES, 2015, 20 (02) : 194 - 199
  • [3] Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems
    Mullins, Garrett R.
    Bruns, David E.
    [J]. CLINICA CHIMICA ACTA, 2017, 473 : 9 - 13
  • [4] Interindividual variability of hemolysis in plasma samples during pneumatic tube system transport
    Gomez-Rioja, Ruben
    Fernandez-Calle, Pilar
    Alcaide, Maria J.
    Madero, Rosario
    Oliver, Paloma
    Iturzaeta, Jose M.
    Buno, Antonio
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (10) : E231 - E233
  • [5] Transport of blood gas samples - Is the pneumatic tube system safe?
    Zanner, R.
    Moser, N.
    Blobner, M.
    Luppa, P. B.
    [J]. ANAESTHESIST, 2006, 55 (10): : 1099 - 1104
  • [6] HEMOLYSIS OF BLOOD SPECIMENS TRANSPORTED FROM ED TO LABORATORY BY PNEUMATIC TUBE
    STAIR, TO
    HOWELL, JM
    FITZGERALD, DJ
    BAILEY, SC
    BASTASCH, MD
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1995, 13 (04): : 484 - 484
  • [7] THE EFFECT OF PNEUMATIC TUBE SYSTEMS ON THE HEMOLYSIS OF BIOCHEMISTRY BLOOD SAMPLES
    Cakirca, Gokhan
    Erdal, Huseyin
    [J]. JOURNAL OF EMERGENCY NURSING, 2017, 43 (03) : 255 - 258
  • [8] Effects of a pneumatic tube system on the hemolysis of blood samples: a PRISMA-compliant meta-analysis
    Ding, Xuemei
    Wen, Xiulin
    Wang, Liying
    Chen, Ting
    Zhou, Guangxia
    He, Hairong
    Xin, Xia
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2021, 81 (05): : 343 - 352
  • [9] Are TEG® results in healthy blood donors affected by the transport of blood samples in a pneumatic tube system?
    Espinosa, A.
    Ruckert, A.
    Navarro, J.
    Videm, V.
    Sletta, V.
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 (04) : E73 - E76
  • [10] Pneumatic tube system for blood products transport
    Bardiaux, L.
    Boulanger, E.
    des Floris, M. -F. Leconte
    Bourcier, V.
    Cottier, D.