PATTERN-RECOGNITION BY THE USE OF MULTIVARIATE STATISTICAL EVALUATION OF MACRO-PIXE AND MICRO-PIXE RESULTS

被引:5
|
作者
TAPPER, UAS
LOVESTAM, NEG
SWIETLICKI, E
MALMQVIST, KG
SALFORD, LG
机构
[1] CENT BUR NUCL MEASUREMENTS,COMISS EUROPEAN COMMUNITIES,JOINT RES CTR,B-2440 GEEL,BELGIUM
[2] UNIV LUND HOSP,DEPT NEUROSURG,DIV EXPTL NEUROONCOL,S-22185 LUND,SWEDEN
关键词
D O I
10.1016/0168-583X(91)95512-C
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The importance of statistical evaluation of multielemental data is illustrated using the data collected in a macro- and micro-PIXE analysis of human brain tumours. By employing a multivariate statistical classification methodology (SIMCA) it was shown that the total information collected from each specimen separates three types of tissue: High malignant, less malignant and normal brain tissue. This makes a classification of a given specimen possible based on the elemental concentrations. Partial least squares regression (PLS), a multivariate regression method, made it possible to study the relative importance of the examined nine trace elements, the dry/wet weight ratio and the age of the patient in predicting the survival time after operation for patients with the high malignant form, astrocytomas grade III-IV. The elemental maps from a microprobe analysis were also subjected to multivariate analysis. This showed that the six elements sorted into maps could be presented in three maps containing all the relevant information. The intensity in these maps is proportional to the value (score) of the actual pixel along the calculated principal components.
引用
收藏
页码:191 / 196
页数:6
相关论文
共 46 条
  • [1] MACRO-PIXE AND MICRO-PIXE ANALYSES OF BIOLOGICAL AND MEDICAL SAMPLES
    VIS, RD
    VANDERSTAP, CCAH
    BOS, AJJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 3 (1-3): : 319 - 325
  • [2] THE INFLUENCE OF SAMPLE ROUGHNESS ON THE QUANTIFICATION OF MICRO-PIXE RESULTS
    ORLIC, I
    VANLANGEVELDE, F
    VIS, RD
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4): : 74 - 77
  • [3] Combination of micro-PIXE with the pattern recognition technique for the source identification of individual aerosol particles
    Guo, P
    Wang, J
    Li, X
    Zhu, J
    Reinert, T
    Heitmann, J
    Spemann, D
    Vogt, J
    Flagmeyer, RH
    Butz, T
    [J]. APPLIED SPECTROSCOPY, 2000, 54 (06) : 807 - 811
  • [4] Concentration and distribution of cobalt in higher plants: The use of micro-PIXE spectroscopy
    Bakkaus, E
    Gouget, B
    Gallien, JP
    Khodja, H
    Carrot, F
    Morel, JL
    Collins, R
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 231 : 350 - 356
  • [5] Micro-PIXE evaluation of radioactive cesium transfer in contaminated soil samples
    Fujishiro, F.
    Ishii, K.
    Matsuyama, S.
    Arai, H.
    Ishizaki, A.
    Osada, N.
    Sugai, H.
    Kusano, K.
    Nozawa, Y.
    Yamauchi, S.
    Karahashi, M.
    Oshikawa, S.
    Kikuchi, K.
    Koshio, S.
    Watanabe, K.
    Suzuki, Y.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 318 : 99 - 101
  • [6] Preliminary results of Sr:Ca ratios of Coilia nasus in otoliths by micro-PIXE
    Zhong, L.
    Guo, H.
    Shen, H.
    Li, X.
    Tang, W.
    Liu, J.
    Jin, J.
    Mi, Y.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 260 (01): : 349 - 352
  • [7] Evaluation of specimen preparation techniques for micro-PIXE localisation of elements in hyperaccumulating plants
    Kachenko, Anthony G.
    Siegele, Rainer
    Bhatia, Naveen P.
    Singh, Balwant
    Ionescu, Mihail
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (08): : 1598 - 1604
  • [8] The use of the maximum entropy method for the improvement of the spatial resolution of the micro-PIXE maps
    Rokita, E
    Maj, B
    Mutsaers, PHA
    deVoigt, MJA
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 130 (1-4): : 138 - 143
  • [9] MULTIVARIATE STATISTICAL PATTERN-RECOGNITION WITH NONREDUCED DIMENSIONALITY
    GRIM, J
    [J]. KYBERNETIKA, 1986, 22 (02) : 142 - 157
  • [10] External Micro-PIXE Measurements: Preliminary Results on Volcanic Rocks from Nyiragongo Volcano
    Alba P. Santo
    Mariaelena Fedi
    Lorenzo Giuntini
    Pier Andrea Mandò
    Mirko Massi
    Francesco Taccetti
    [J]. Microchimica Acta, 2006, 155 : 263 - 267