COMPARISON OF 5F AND 7/8F CATHETERS FOR LEFT-VENTRICULAR AND CORONARY ANGIOGRAPHY

被引:16
|
作者
HUI, WKK
KLINKE, WP
KUBAC, G
TALIBI, T
机构
[1] Division of Cardiology, Department of Medicine, Royal Alexandra Hospital, Edmonton, Alberta
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1990年 / 19卷 / 02期
关键词
cardiac catheterization; complications; coronary artery disease;
D O I
10.1002/ccd.1810190204
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fifty‐two patients were randomized into two groups of 26 to the use of either 5 or 7/8F catheters for their first left heart cardiac catheterization. Clinical characteristics for the two groups were similar. 5F catheters were significantly inferior to 7/8F catheters in terms of torque control (P<.001), ease of engaging coronary ostia (P<.001), and quality of angiograms (P<.05). Nine patients in the 5F group required a change to 7/8F catheters for completion of the procedure. There was no difference in procedure time or fluoroscopy time between the groups. Time to haemostasis was significantly shorter in the 5F group (P<.01), but there was no difference between groups with respect to haematoma formation or rebleed after haemostasis. We conclude the slight advantage of 5F catheters in terms of haemostasis is outweighed by many disadvantages. Their routine use in cardiac catheterization, at least at this time, cannot be recommended. Copyright © 1990 John Wiley & Sons, Ltd.
引用
收藏
页码:84 / 86
页数:3
相关论文
共 50 条
  • [1] COMPARISON OF 5F AND 7/8F CATHETERS FOR LEFT HEART CATHETERIZATION AND ANGIOGRAPHY
    KLINKE, WP
    HUI, W
    KUBAC, G
    TALIBI, T
    CLINICAL RESEARCH, 1989, 37 (01): : A95 - A95
  • [2] ARE SMALLER CATHETERS BETTER - COMPARISON OF 5F, 6F, AND 8F IN CARDIAC-CATHETERIZATION
    TALLEY, JD
    JOSEPH, A
    YUSSMAN, ZA
    PRINCE, C
    SINGER, I
    KUPERSMITH, J
    CLINICAL RESEARCH, 1990, 38 (02): : A505 - A505
  • [3] TIME TO ACHIEVE HEMOSTASIS WITH 8F VS 5F CATHETERS IS NOT SIGNIFICANT - REPLY
    MOLAJO, AO
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1988, 14 (04): : 291 - 291
  • [4] Variability in estimation of coronary dimensions from 6F and 8F catheters
    Legrand, V
    Raskinet, B
    Martinez, C
    Kulbertus, H
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1996, 37 (01): : 39 - 45
  • [5] Comparison of 6F with 7F and 8F guiding catheters for elective coronary angioplasty: Results of a prospective, multicenter, randomised trial
    Metz, D
    Meyer, P
    Touati, C
    Coste, P
    Petiteau, PY
    Durand, P
    Faivre, R
    Lefevre, T
    Elaerts, J
    AMERICAN HEART JOURNAL, 1997, 134 (01) : 131 - 137
  • [6] COMPARISON OF THE PERFORMANCE OF SUPERFLOW (5F) AND CONVENTIONAL 8F CATHETER FOR CARDIAC-CATHETERIZATION BY THE FEMORAL ROUTE
    MOLAJO, AO
    WARD, C
    BRAY, CL
    DOBSON, D
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1987, 13 (04): : 275 - 276
  • [7] COMPLICATIONS OF DAY-CASE ANGIOGRAPHY USING 5F CATHETERS
    JEWELL, FM
    WALSH, S
    MURPHY, P
    JONES, AJ
    CLINICAL RADIOLOGY, 1995, 50 (02) : 102 - 104
  • [8] Diagnostic angiography with 5F catheters supports early ambulation and discharge
    Gatt, V.
    Borg, M.
    Agius, J.
    Fenech, A.
    Xuereb, R. G.
    Grech, V.
    EUROPEAN HEART JOURNAL, 2012, 33 : 761 - 761
  • [9] Ventricular arrhythmia onset during diagnostic coronary angiography with a 5F or 4F universal catheter
    Chen, Jun
    Gao, LiJian
    Yao, Min
    Chen, Jilin
    REVISTA ESPANOLA DE CARDIOLOGIA, 2008, 61 (10): : 1092 - 1095
  • [10] COMPARISON OF IOPROMIDE AND IOPAMIDOL IN LEFT-VENTRICULAR ANGIOGRAPHY AND IN CORONARY ANGIOGRAPHY
    DYET, JF
    CARTER, EC
    HARTLEY, WC
    BRITISH JOURNAL OF RADIOLOGY, 1990, 63 (753): : 700 - 705