VALIDATION-STUDY OF ALTERNATIVES TO THE DRAIZE EYE IRRITATION TEST IN GERMANY - CYTOTOXICITY TESTING AND HET CAM TEST WITH 136 INDUSTRIAL-CHEMICALS

被引:66
|
作者
SPIELMANN, H
KALWEIT, S
LIEBSCH, M
WIRNSBERGER, T
GERNER, I
BERTRAMNEIS, E
KRAUSER, K
KREILING, R
MILTENBURGER, HG
PAPE, W
STEILING, W
机构
[1] BGA,MAX V PETTENKOFER INST,W-1000 BERLIN 33,GERMANY
[2] WELLA AG,W-6100 DARMSTADT,GERMANY
[3] ASTA MED AG,INST TOXIKOL,W-4802 HALLE KUNSEBECK,GERMANY
[4] HOECHST AG,INST TOXIKOL,W-6230 FRANKFURT,GERMANY
[5] TH DARMSTADT,INST ZOOL,W-6100 DARMSTADT,GERMANY
[6] BEIERSDORF AG,W-2000 HAMBURG 20,GERMANY
[7] HENKEL KGAA,TFB TOXIKOL,W-4000 DUSSELDORF,GERMANY
关键词
D O I
10.1016/0887-2333(93)90055-A
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
According to OECD guideline 405 revised in 1987 Draize eye tests need not be performed for severely irritating and corrosive chemicals if results from 'well-validated alternative studies' are presented. In 1988 a validation study on alternatives to the Draize eye test was started in Germany to establish 'well-validated alternative methods' for this purpose. During database development, the last stage of the validation programme, 136 chemicals from the German chemical industry were classified in a blind trial with the 3T3 cell neutral red/kenacid blue cytotoxicity assay and the hen's egg chorioallantoic membrane (HET-CAM) test using fertile chicken eggs. The major goal of this stage of validation was to demonstrate the feasibility and limitations of the two alternative methods. Chemicals were, therefore, selected as representatives of chemical structural groups as well as of physicochemical and toxicological properties. In addition, some of the chemicals were chosen because they were of interest to the cosmetic and detergent industries. Draize eye testing data in vivo were provided by industry. In contrast to data from a previous interlaboratory assessment trial, it was impossible to correlate cytotoxicity data to the EEC classification for in vivo eye irritation. However, seven of 10 severely irritating chemicals (EEC labelling R-41) could be identified correctly in the HET-CAM assay, whereas test conditions of the study described here did not allow identification of irritating chemicals (EEC labelling R-36). The HET-CAM test is, therefore, fulfilling the criteria of a 'well-validated alternative method' according to OECD guideline 405 and should be incorporated into eye irritation testing at the earliest possible stage to reduce effectively the suffering of rabbits in the Draize eye test. Although an 80% correct prediction of 'non-labelled' chemicals in the HET-CAM test is encouraging, for safety assessment of non-irritant chemicals, for use as cosmetic formulations, for example, both government and industry will accept an in vitro assay only if its prediction of the absence of irritant properties is 100% correct.
引用
收藏
页码:505 / 510
页数:6
相关论文
共 22 条
  • [1] Results of a validation study in Germany on two in vitro alternatives to the Draize eye irritation test, the HET-CAM test and the 3T3 NRU cytotoxicity test
    Spielmann, H
    Liebsch, M
    Kalweit, S
    Moldenhauer, F
    Wirnsberger, T
    Holzhutter, HG
    Schneider, B
    Glaser, S
    Gerner, I
    Pape, WJW
    Kreiling, R
    Krauser, K
    Miltenburger, HG
    Steiling, W
    Luepke, NP
    Muller, N
    Kreuzer, H
    Murmann, P
    Spengler, J
    BertramNeis, E
    Siegemund, B
    Wiebel, FJ
    [J]. ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 1996, 24 (05): : 741 - 858
  • [2] INTERLABORATORY ASSESSMENT OF ALTERNATIVES TO THE DRAIZE EYE IRRITATION TEST IN GERMANY
    SPIELMANN, H
    GERNER, I
    KALWEIT, S
    MOOG, R
    WIRNSBERGER, T
    KRAUSER, K
    KREILING, R
    KREUZER, H
    LUPKE, NP
    MILTENBURGER, HG
    MULLER, N
    MURMANN, P
    PAPE, W
    SIEGEMUND, B
    SPENGLER, J
    STEILING, W
    WIEBEL, FJ
    [J]. TOXICOLOGY IN VITRO, 1991, 5 (5-6) : 539 - 542
  • [3] The EC/HO international validation study on alternatives to the Draize eye irritation test
    Balls, M
    Botham, PA
    Bruner, LH
    Spielmann, H
    [J]. TOXICOLOGY IN VITRO, 1995, 9 (06) : 871 - 929
  • [4] Evaluation of the HET-CAM-TSA method as an alternative to the Draize eye irritation test
    Gilleron, L
    Coecke, S
    Sysmans, M
    Hansen, E
    VanOproy, S
    Marzin, D
    VanCauteren, H
    Vanparys, P
    [J]. TOXICOLOGY IN VITRO, 1997, 11 (05) : 641 - 644
  • [5] A tiered in vitro/in vivo testing strategy to classify severely eye irritating chemicals using two alternatives to the draize eye test, the HET-CAM test and the 3T3 NRU cytotoxicity test
    Spielmann, H
    Liebsch, M
    Kalweit, S
    Moldenhauer, F
    Wirnsberger, T
    Holzhütter, HG
    Schneider, B
    Glaser, S
    Gerner, I
    Pape, WJW
    Kreiling, R
    Krauser, K
    Miltenburger, HG
    Steiling, W
    Luepke, NP
    Günzel, P
    Müller, N
    Kreuzer, H
    Murmann, P
    Spengler, J
    Bertram-Neis, E
    Siegemund, B
    Wiebel, FJ
    [J]. ALTERNATIVES TO ANIMAL TESTING II, PROCEEDINGS, 1999, : 205 - 210
  • [6] A summary report of the COLIPA international validation study on alternatives to the Draize rabbit eye irritation test
    Brantom, PG
    Bruner, LH
    Chamberlain, M
    DeSilva, O
    Dupuis, J
    Earl, LK
    Lovell, DP
    Pape, WJW
    Uttley, M
    Bagley, DM
    Baker, FW
    Bracher, M
    Courtellemont, P
    Declercq, I
    Freeman, S
    Steiling, W
    Walker, AP
    Carr, GJ
    Dami, N
    Thomas, G
    Harbell, J
    Jones, PA
    Pfannenbecker, U
    Southee, JA
    Tcheng, M
    Argembeaux, H
    Castelli, D
    Clothier, R
    Esdaile, DJ
    Itigaki, H
    Jung, K
    Kasai, Y
    Kojima, H
    Kristen, U
    Larnicol, M
    Lewis, RW
    Marenus, K
    Moreno, O
    Peterson, A
    Rasmussen, ES
    Robles, C
    Stern, M
    [J]. TOXICOLOGY IN VITRO, 1997, 11 (1-2) : 141 - 179
  • [7] THE HET-CAM TEST - A STUDY OF THE IRRITATION POTENTIAL OF CHEMICALS AND FORMULATIONS
    DESILVA, O
    ROUGIER, A
    DOSSOU, KG
    [J]. ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 1992, 20 (03): : 432 - 437
  • [8] COMPARATIVE-STUDY OF THE HET-CAM TEST AND THE DRAIZE EYE TEST FOR ASSESSMENT OF IRRITANCY POTENTIAL
    VINARDELL, MP
    MACIAN, M
    [J]. TOXICOLOGY IN VITRO, 1994, 8 (03) : 467 - 470
  • [9] MODERN BIOSTATISTICAL METHODS FOR ASSESSING IN-VITRO IN-VIVO CORRELATION OF SEVERELY EYE IRRITATING CHEMICALS IN A VALIDATION-STUDY OF IN-VITRO ALTERNATIVES TO THE DRAIZE EYE TEST
    SPIELMANN, H
    LIEBSCH, M
    MOLDENHAUER, F
    HOLZHUTTER, HG
    DESILVA, O
    [J]. TOXICOLOGY IN VITRO, 1995, 9 (04) : 549 - 556
  • [10] Experiences in routine testing: Comparing results of the HET-CAM and the Rabbit Eye Irritation Test for a broad variety of chemicals and formulations
    Schrage, A.
    Gamer, A. O.
    van Ravenzwaay, B.
    Landsiedel, R.
    [J]. NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2010, 381 : 83 - 83