BRAIN-TISSUE VOLUME MEASUREMENT FROM MAGNETIC-RESONANCE-IMAGING - A PHANTOM STUDY

被引:29
|
作者
RUSINEK, H
CHANDRA, R
机构
[1] Department of Radiology, New York University Medical Center, New York, NY
关键词
MAGNETIC RESONANCE IMAGING; IMAGE ANALYSIS; BRAIN VOLUME MEASUREMENT; PHANTOM STUDIES;
D O I
10.1097/00004424-199310000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors appraised the accuracy of a method for brain volume measurement from magnetic resonance images and evaluated the effects of the acquisition matrix, slice thickness. and tissue sampling on the measurement error. METHODS. The method uses two magnetic resonance imaging sequences to account explicitly for partial volume effects. The accuracy was measured with one-, two-, and three-compartmental phantoms that mimic the relaxation properties of brain tissues. The sensitivity of the method to section thickness was measured by repeated scans of human brain. RESULTS. Using a strongly T2-weighted sequence and two-compartmental phantoms, the average error was 5%, with 3% error for phantoms larger than 90 mL. In the three-compartmental phantoms the error varied from 2% to 7%. Varying the section thickness from 5 to 10 mm on three-compartmental phantoms and from 2.5 to 10 mm in the human brain did not significantly affect compartmental volumes. CONCLUSIONS. The experimental study validates the feasibility of monitoring localized volume changes in a three-compartmental model.
引用
收藏
页码:890 / 895
页数:6
相关论文
共 50 条
  • [1] SEGMENTATION TECHNIQUES FOR THE CLASSIFICATION OF BRAIN-TISSUE USING MAGNETIC-RESONANCE-IMAGING
    COHEN, G
    ANDREASEN, NC
    ALLIGER, R
    ARNDT, S
    KUAN, J
    YUH, WTC
    EHRHARDT, J
    [J]. PSYCHIATRY RESEARCH-NEUROIMAGING, 1992, 45 (01) : 33 - 51
  • [2] H-1 MAGNETIC-RESONANCE-IMAGING OF NORMAL BRAIN-TISSUE RESPONSE TO PHOTODYNAMIC THERAPY
    JIANG, Q
    KNIGHT, RA
    CHOPP, M
    HELPERN, JA
    ORDIDGE, RJ
    QING, ZX
    HETZEL, FW
    [J]. NEUROSURGERY, 1991, 29 (04) : 538 - 543
  • [3] MEASUREMENT OF BREAST IMPLANT VOLUME WITH MAGNETIC-RESONANCE-IMAGING
    MINEYEV, M
    KRAMER, D
    KAUFMAN, L
    CARLSON, J
    FRANKEL, S
    [J]. ANNALS OF PLASTIC SURGERY, 1995, 34 (04) : 348 - 351
  • [4] MAGNETIC-RESONANCE-IMAGING OF AORTIC ANEURYSMAL PHANTOM
    SAKAKIBARA, M
    KOBAYASHI, S
    IMAI, H
    WATANABE, S
    MASUDA, Y
    INAGAKI, Y
    MORITA, H
    UEMATSU, S
    ARIMIZU, N
    [J]. BIORHEOLOGY, 1986, 23 (05) : 536 - 536
  • [5] MAGNETIC-RESONANCE-IMAGING OF THE BRAIN
    WALLACE, CJ
    [J]. JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1991, 42 (01): : 13 - 20
  • [6] BRAIN AND MAGNETIC-RESONANCE-IMAGING
    OUCHI, T
    [J]. APPLIED RADIATION AND ISOTOPES, 1986, 37 (01) : 78 - 78
  • [7] COMPUTERIZED BRAIN-TUMOR VOLUME MEASUREMENT METHOD ON MAGNETIC-RESONANCE-IMAGING HARD COPIES
    TUMA, R
    BEVILACQUA, R
    BEATIE, B
    KROL, G
    POSNER, JB
    [J]. ANNALS OF NEUROLOGY, 1993, 34 (02) : 315 - 315
  • [8] ESTIMATION OF TONGUE VOLUME FROM MAGNETIC-RESONANCE-IMAGING
    LAUDER, R
    MUHL, ZF
    [J]. ANGLE ORTHODONTIST, 1991, 61 (03) : 175 - 184
  • [9] ANATOMIC BASIS OF AMYGDALOID AND HIPPOCAMPAL VOLUME MEASUREMENT BY MAGNETIC-RESONANCE-IMAGING
    WATSON, C
    ANDERMANN, F
    GLOOR, P
    JONESGOTMAN, M
    PETERS, T
    EVANS, A
    OLIVIER, A
    MELANSON, D
    LEROUX, G
    [J]. NEUROLOGY, 1992, 42 (09) : 1743 - 1750
  • [10] BRAIN MATURATION AND MAGNETIC-RESONANCE-IMAGING
    GABRIELLI, O
    COPPA, GV
    GIORGI, P
    SALVOLINI, U
    [J]. JOURNAL OF PEDIATRICS, 1990, 117 (04): : 675 - 675