UMBILICAL ARTERY FLOW VELOCITY DURING MATERNAL CARDIOPULMONARY BYPASS

被引:16
|
作者
GOLDSTEIN, I
JAKOBI, P
GUTTERMAN, E
MILO, S
机构
[1] RAMBAM MED CTR,DEPT OBSTET & GYNECOL,IL-31906 HAIFA,ISRAEL
[2] TECHNION ISRAEL INST TECHNOL,FAC MED,RAMBAM MED CTR,DEPT OBSTET & GYNECOL,HAIFA,ISRAEL
[3] TECHNION ISRAEL INST TECHNOL,FAC MED,RAMBAM MED CTR,DEPT CARDIAC SURG,HAIFA,ISRAEL
来源
ANNALS OF THORACIC SURGERY | 1995年 / 60卷 / 04期
关键词
D O I
10.1016/0003-4975(95)00673-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The fetal death rate associated with cardiac operations using cardiopulmonary bypass in pregnant women is as high as 9.5% to 29%. We present a case in which fetal heart rate and umbilical artery flow velocity waveforms were continuously monitored by transvaginal ultrasonography and analyzed in relation to events of the cardiopulmonary bypass. Our findings suggest that hypothermia during cardiopulmonary bypass has potentially deleterious effects on the fetus and should be avoided if possible.
引用
收藏
页码:1116 / 1118
页数:3
相关论文
共 50 条
  • [1] PHYSIOLOGICAL SIGNIFICANCE OF BRONCHIAL ARTERY FLOW DURING CARDIOPULMONARY BYPASS
    SATINSKY, VP
    AMERICAN JOURNAL OF CARDIOLOGY, 1965, 15 (01): : 144 - &
  • [2] EFFECT OF MATERNAL POSTURE ON THE UMBILICAL ARTERY FLOW VELOCITY WAVE-FORM
    VANKATWIJK, C
    WLADIMIROFF, JW
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (07): : 683 - 685
  • [3] Changes in umbilical artery flow velocity waveforms following maternal administration of betamethasone
    Edwards, A
    Baker, LS
    Wallace, EM
    PLACENTA, 2003, 24 (01) : 12 - 16
  • [4] CHANGES IN BLOOD-FLOW VELOCITY IN THE MIDDLE CEREBRAL-ARTERY DURING NONPULSATILE HYPOTHERMIC CARDIOPULMONARY BYPASS
    ENDOH, H
    SHIMOJI, K
    STROKE, 1994, 25 (02) : 403 - 407
  • [5] Milrinone increases middle cerebral artery blood flow velocity after cardiopulmonary bypass
    Sulek, CA
    Blas, ML
    Lobato, EB
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (01) : 64 - 69
  • [6] CARDIOPULMONARY BYPASS AND PRECEREBRAL ARTERY-OCCLUSION - INDIVIDUALIZED BYPASS GUIDED BY MIDDLE CEREBRAL-ARTERY FLOW VELOCITY MONITORING
    LUNDAR, T
    LINDEGAARD, KF
    ROSTAD, H
    AMHOLEN, E
    GEIRAN, O
    NORNES, H
    ACTA NEUROLOGICA SCANDINAVICA, 1987, 76 (05): : 395 - 395
  • [7] Cerebral blood flow velocity during cardiopulmonary bypass in carotid stenosis patients
    Goto, T
    Baba, T
    Shibata, Y
    Kubota, F
    Taguchi, H
    ANESTHESIA AND ANALGESIA, 1999, 88 (04): : U11 - U11
  • [8] Adaptation of flow pump cardiopulmonary bypass to lean body mass during coronary artery bypass
    Ennaas, I.
    Sellami, W.
    Hajjej, Z.
    Massoudi, A.
    Lebbi, A.
    Gharsallah, H.
    Labbene, I.
    Ferjani, M.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 : A275 - A276
  • [9] CEREBRAL BLOOD-FLOW VELOCITY PATTERNS DURING LOW-FLOW CARDIOPULMONARY BYPASS
    EHRLICH, I
    BURROWS, FA
    BISSONNETTE, B
    STROKE, 1992, 23 (03) : 471 - 471
  • [10] UMBILICAL ARTERY FLOW VELOCITY WAVEFORMS IN LABOR
    FAIRLIE, FM
    LANG, GD
    SHELDON, CD
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1989, 96 (02): : 151 - 157