TRANSTHORACIC ELECTRICAL IMPEDANCE - QUANTITATIVE EVALUATION OF A NON-INVASIVE MEASURE OF THORACIC FLUID VOLUME

被引:131
|
作者
LUEPKER, RV [1 ]
MICHAEL, JR [1 ]
WARBASSE, JR [1 ]
机构
[1] PHS HOSP,CARDIOVASC SERV & LAB,BALTIMORE,MD 21211
关键词
D O I
10.1016/0002-8703(73)90529-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:83 / 93
页数:11
相关论文
共 50 条
  • [1] TRANSTHORACIC ELECTRICAL IMPEDANCE - NON-INVASIVE MEASURE OF PULMONARY-EDEMA IN ACUTE MYOCARDIAL-INFARCTION
    CARALIS, DG
    LUEPKER, RV
    VOIGT, GC
    BURNS, RF
    WARBASSE, JR
    CIRCULATION, 1974, 50 (04) : 164 - 164
  • [2] Thoracic electrical bioimpedance: a non-invasive measure of cardiac output for porcine research
    Broomhead, CJ
    Wright, SJ
    Kiff, KM
    Withington, PS
    LABORATORY ANIMALS, 1998, 32 (03) : 324 - 329
  • [3] NON-INVASIVE EVALUATION OF THORACIC ANEURYSMS
    GOMES, MN
    HUFNAGEL, CA
    SCHELLINGER, D
    KIRSCHNER, LP
    COMPUTERIZED RADIOLOGY, 1983, 7 (05): : 267 - 277
  • [4] Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers
    Harford M.
    Clark S.H.
    Smythe J.F.
    Gerry S.
    Villarroel M.
    Jorge J.
    Chaichulee S.
    Tarassenko L.
    Young D.
    Watkinson P.
    Journal of Medical Engineering and Technology, 2019, 43 (01): : 33 - 37
  • [5] Transthoracic electrical bioimpedance: A non-invasive technique for the evaluation of the haemodynamic alterations in patients with liver cirrhosis
    Dazzani, F
    Micati, M
    Caraceni, P
    Drago, GM
    Domenicali, M
    Pacilli, P
    Tomassetti, V
    Gelonesi, E
    Trevisani, F
    Bernardi, M
    DIGESTIVE AND LIVER DISEASE, 2005, 37 (10) : 786 - 792
  • [6] CLINICAL EVALUATION OF TRANSTHORACIC ELECTRICAL IMPEDANCE AS A GUIDE TO INTRATHORACIC FLUID VOLUMES
    POMERANTZ, M
    DELGADO, F
    EISEMAN, B
    ANNALS OF SURGERY, 1970, 171 (05) : 686 - +
  • [7] Non-invasive urine volume estimation in the bladder by electrical impedance-based methods: A review
    Noyori, Shuhei S.
    Nakagami, Gojiro
    Sanada, Hiromi
    MEDICAL ENGINEERING & PHYSICS, 2022, 101
  • [8] Non-invasive measurement of normal skin impedance for determining the volume of the transdermally extracted interstitial fluid
    Li, Dachao
    Pu, Zhihua
    Liang, Wenshuai
    Liu, Tongkun
    Wang, Ridong
    Yu, Haixia
    Xu, Kexin
    MEASUREMENT, 2015, 62 : 215 - 221
  • [9] EVALUATION OF ELECTRICAL-IMPEDANCE PLETHYSMOGRAPHY FOR NON-INVASIVE MEASUREMENT OF BLOOD-FLOW
    ARENSON, HM
    MOHAPATRA, S
    BRITISH JOURNAL OF ANAESTHESIA, 1977, 49 (02) : 185 - 185
  • [10] Non-Invasive Electromagnetic Skin Patch Sensor to Measure Intracranial Fluid-Volume Shifts
    Griffith, Jacob
    Cluff, Kim
    Eckerman, Brandon
    Aldrich, Jessica
    Becker, Ryan
    Moore-Jansen, Peer
    Patterson, Jeremy
    SENSORS, 2018, 18 (04)