摘要
High current, short length ion beam pulses appear to be a new alternative for surface property modification of solids, due to the combined effect of ion implantation with induced fast heating-cooling which this process presents. The repetitive pulsed nitrogen implantation (with a low energy plasma focus) of pure titanium with different pulse lengths (300 and 400 ns), and fluences per pulse ranging between 1.4 x 10(14) and 1 x 10(15) cm(-2), with total accumulated fluences between 7 x 10(14) and 1.6 x 10(16) showed a surface heating effect with important compositional and physical changes in the layers close to the surface. XPS analysis showed TiN0.8, formation independent of the total range of fluences used, with an increase in the superficial microhardness, when short pulse lengths were used. A correlation between the N/Ti concentration ratio, the binding energy difference (Ti2p(3/2)-N1s) and the x value in the stoichiometry of the TiNx compound formed was observed for the long pulse length case.
引用
下载
收藏
页码:267 / 275
页数:9
相关论文
共 50 条
  • [1] EFFECTS OF TIN ION AND NITROGEN ION-IMPLANTATION ON THE OXIDATION OF TITANIUM
    MADAKSON, P
    MATERIALS SCIENCE AND ENGINEERING, 1987, 90 : 205 - 212
  • [2] FORMATION OF A TINX PROTECTIVE LAYER BY NITROGEN ION-IMPLANTATION INTO TITANIUM
    KUZNETSOV, MV
    GAVRILOV, NV
    GUBANOV, VA
    VACUUM, 1991, 42 (12) : 731 - 734
  • [3] THE IMPROVEMENT IN FATIGUE LIFE OF PURE POLYCRYSTALLINE NICKEL BY NITROGEN ION-IMPLANTATION
    XU, MH
    PATU, S
    WANG, ZG
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1988, 105 (02): : 419 - 425
  • [4] SYNTHESIS OF COMPOUNDS BY HIGH-FLUENCE NITROGEN ION-IMPLANTATION IN TITANIUM
    RAUSCHENBACH, B
    HOCHMUTH, K
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1986, 94 (02): : 833 - 837
  • [5] FORMATION OF COMPOUNDS BY HIGH-FLUX NITROGEN ION-IMPLANTATION IN TITANIUM
    RAUSCHENBACH, B
    JOURNAL OF MATERIALS SCIENCE, 1986, 21 (02) : 395 - 404
  • [6] CARBON ION-IMPLANTATION OF PURE IRON
    SRIDHARAN, K
    CONRAD, JR
    DODD, RA
    WORZALA, FJ
    SCRIPTA METALLURGICA ET MATERIALIA, 1992, 26 (07): : 1037 - 1042
  • [7] YTTRIUM ION-IMPLANTATION IN PURE ALUMINUM
    JI, CZ
    NING, XG
    WANG, AM
    YANG, JH
    SURFACE & COATINGS TECHNOLOGY, 1994, 66 (1-3): : 240 - 244
  • [8] PULSED ION-IMPLANTATION OF SILICON WITH SELENIUM
    SERFOZO, G
    NAUJOKAITIS, R
    KRAFCSIK, I
    DOZSA, L
    BATTISTIG, G
    RIEDL, P
    KLOPFER, E
    GERASIMENKO, NN
    GYULAI, J
    EPM 87: ENERGY PULSE AND PARTICLE BEAM MODIFICATION OF MATERIALS, 1988, 8 : 74 - 79
  • [9] COMPARATIVE STATUS OF PULSED ION-IMPLANTATION
    GYULAI, J
    KRAFCSIK, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 37-8 : 275 - 279
  • [10] EFFECT OF ION-IMPLANTATION ON CORROSION BEHAVIOR OF PURE IRON .4. LEAD ION-IMPLANTATION
    ASHWORTH, V
    GRANT, WA
    PROCTER, RPM
    WRIGHT, EJ
    CORROSION SCIENCE, 1978, 18 (08) : 681 - 685