MULTICENTER IMMUNOSCINTIGRAPHIC STUDY USING INDIUM-111-LABELED CEA-SPECIFIC AND/OR 19-9 MONOCLONAL-ANTIBODY F(AB')2 FRAGMENTS

被引:14
|
作者
CHETANNEAU, A
BAUM, RP
LEHUR, PA
LIEHN, JC
PERKINS, AC
BARES, R
BOURGUET, P
HERRY, JY
SACCAVINI, JC
CHATAL, JF
机构
[1] INSERM,RES UNIT 211,F-44035 NANTES,FRANCE
[2] JOHANN WOLFGANG GOETHE UNIV HOSP,W-6000 FRANKFURT 70,GERMANY
[3] INST JEAN GODINOI,F-51056 REIMS,FRANCE
[4] UNIV NOTTINGHAM HOSP,QUEENS MED CTR,NOTTINGHAM NG7 2UH,ENGLAND
[5] RHEIN WESTFAL TH AACHEN,DEPT NUCL MED,W-5100 AACHEN,GERMANY
[6] CTR E MARQUIS,F-35033 RENNES,FRANCE
[7] CIS BIOIND,F-91191 GIF SUR YVETTE,FRANCE
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1990年 / 17卷 / 05期
关键词
Colorectal carcinoma; Fragments; Indium; 111; Monoclonal antibodies;
D O I
10.1007/BF00812361
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Six European nuclear medicine centres per formed immunoscintigraphy first retrospectively in 34 patients using indium-111-labelled carcinoembryonic antigen (CEA)-specific and/or 19-9 F(ab')2 fragments. Results for sensitivity and specificity in tumour sites were 94% and 87%, respectively, for the pelvis and 73% and 100% for the extrahepatic abdomen. A second prospective series concerned 58 other patients previously operated on for colorectal adenocarcinoma (27 colon, 31 rectum). Two-thirds of these patients had a suspected recurrence signalled by an isolated rise in tumour markers, and 46 patients examined by immunoscintigraphy, X-ray computed tomography and ultrasonography were found to have a recurrence (a total of 62 tumour sites). Sensitivity and specificity with immunoscintigraphy were 90% and 97%, respectively, for the pelvis and 62% and 95% for the extrahepatic abdomen. For 29 patients injected with CEA-specific fragments, sensitivity was 90% and specificity 94% for the pelvis. For 25 patients injected with 19-9 fragments, pelvic sensitivity and specificity were 80% and 100%, respectively, whereas sensitivity for the extrahepatic abdomen was only 29% since several cases of peritoneal carcinosis were not visualized. In the prospective series, comparison of the three imaging techniques for all tumour sites (including liver and in 5 cases thorax) gave a sensitivity and specificity of 82% and 91 %, respectively, for immunoscintigraphy, 52% and 95% for X-ray computed tomography and 59% and 100% for ultrasonography. These results thus confirm the advantage of using111In-labelled CEA-specific or 19-9 to visualize and localize recurrences of colorectal cancer. © 1990 Springer-Verlag.
引用
收藏
页码:223 / 229
页数:7
相关论文
共 50 条
  • [1] EARLY IMMUNOSCINTIGRAPHIC LOCALIZATION OF A MEDIASTINAL TUMOR WITH INDIUM 111-DTPA CEA-SPECIFIC F(AB')2 MONOCLONAL-ANTIBODY FRAGMENTS (BW 431/31) USING 2ND TRACER ISOCONTOUR TECHNIQUE
    FROHN, J
    BAUM, RP
    HAPP, J
    FALK, S
    RIEMANN, HE
    HOR, G
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 17 (1-2): : 91 - 93
  • [2] RADIOIMMUNOIMAGING OF METASTATIC MEDULLARY CARCINOMA OF THE THYROID-GLAND USING AN INDIUM-111-LABELED MONOCLONAL-ANTIBODY TO CEA
    EDINGTON, HD
    WATSON, CG
    LEVINE, G
    TAUXE, WN
    YOUSEM, SA
    UNGER, M
    KOWAL, CD
    SURGERY, 1988, 104 (06) : 1004 - 1010
  • [3] BEHAVIOR OF IN-111-LABELED F(AB')2 FRAGMENTS (19-9) IN PATIENTS
    DOHERTY, PW
    HNATOWICH, DJ
    CHILDS, R
    KOSCIUCZYK, C
    SCHWINGER, R
    GRIFFIN, T
    SHEALY, D
    MATTIS, J
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05) : P112 - P112
  • [4] DOSIMETRIC EVALUATION OF IMMUNOSCINTIGRAPHY USING INDIUM-111-LABELED MONOCLONAL-ANTIBODY FRAGMENTS IN PATIENTS WITH OVARIAN-CANCER
    BUIJS, WCAM
    MASSUGER, LFAG
    CLAESSENS, RAMJ
    KENEMANS, P
    CORSTENS, FHM
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (06) : 1113 - 1120
  • [5] IMMUNOSCINTIGRAPHY OF OVARIAN-CANCER WITH INDIUM-111-LABELED OV-TL 3 F(AB')2 MONOCLONAL-ANTIBODY
    MASSUGER, LFAG
    KENEMANS, P
    CLAESSENS, RAMJ
    VERHEIJEN, RHM
    SCHIJF, CPT
    STRIJK, SP
    POELS, LG
    VANHOESEL, RGCM
    CORSTENS, FHM
    JOURNAL OF NUCLEAR MEDICINE, 1990, 31 (11) : 1802 - 1810
  • [6] FEASIBILITY STUDY OF RADIOIMMUNOGUIDED SURGERY OF COLORECTAL CARCINOMAS USING IN-111 CEA-SPECIFIC MONOCLONAL-ANTIBODY
    CURTET, C
    VUILLEZ, JP
    DANIEL, G
    AILLET, G
    CHETANNEAU, A
    VISSET, J
    KREMER, M
    THEDREZ, P
    CHATAL, JF
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 17 (6-8): : 299 - 304
  • [7] IMAGING OF COLORECTAL-CANCER USING INDIUM-111-LABELED ANTITUMOUR MONOCLONAL-ANTIBODY
    ARMITAGE, NC
    PERKINS, AC
    PIMM, MV
    BALDWIN, RW
    HARDCASTLE, JD
    BRITISH JOURNAL OF SURGERY, 1985, 72 (05) : 409 - 409
  • [8] BIODISTRIBUTION AND PHARMACOKINETICS OF IN-111 LABELED MONOCLONAL-ANTIBODY F(AB')2 FRAGMENTS IN PATIENTS
    DOHERTY, PW
    BRITISH JOURNAL OF CANCER, 1985, 52 (04) : 646 - 647
  • [9] HISTOLOGICAL CORRELATION OF 17 PROSPECTIVE IMMUNOSCINTIGRAPHIES OF RECURRENCES OF COLORECTAL CARCINOMAS USING INDIUM-111-LABELED ANTI-CEA AND(OR) 19-9 MONOCLONAL-ANTIBODIES
    CHETANNEAU, A
    LEHUR, PA
    RIPOCHE, D
    PELTIER, P
    SACCAVINI, JC
    VUILLEZ, JP
    TOURNEMAINE, N
    THEDREZ, P
    CHATAL, JF
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (06): : 302 - 306
  • [10] IMMUNOSCINTIGRAPHY USING IN-111-LABELED F(AB')(2) FRAGMENTS OF ANTICARCINOEMBRYONIC ANTIGEN (CEA) MONOCLONAL-ANTIBODY FOR STAGING OF NONSMALL CELL LUNG-CARCINOMA
    VUILLEZ, JP
    MORO, D
    BRAMBILLA, E
    BRICHON, PY
    FERRETTI, G
    SACCAVINI, JC
    BRAMBILLA, C
    EUROPEAN JOURNAL OF CANCER, 1994, 30A (08) : 1089 - 1092