THE ACCURACY AND PRECISION OF THE ACCUTRACKER AMBULATORY BLOOD-PRESSURE MONITOR

被引:28
|
作者
APPEL, LJ
WHELTON, PK
SEIDLER, AJ
PATEL, AR
KLAG, MJ
机构
[1] JOHNS HOPKINS MED INST,WELCH CTR PREVENT EPIDEMIOL & CLIN RES,DEPT MED,BALTIMORE,MD 21205
[2] JOHNS HOPKINS MED INST,WELCH CTR PREVENT EPIDEMIOL & CLIN RES,DEPT EPIDEMIOL,BALTIMORE,MD 21205
关键词
Blood pressure; Blood pressure determination; Hypertension; Monitoring; physiologic;
D O I
10.1093/oxfordjournals.aje.a115664
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Prerequisite to the use of ambulatory blood pressure monitors in epidemiologic research is demonstration of a satisfactory level of accuracy and precision. Previous evaluations of these devices raise a number of methodological concerns which complicate interpretation of their findings. Also, important issues regarding the precision of blood pressure measurements and the identification of factors associated with measurement inaccuracies remain unaddressed. To assess the accuracy and precision of the Accutracker ambulatory blood pressure monitor, we obtained five serial estimates of resting blood pressure on 120 ambulatory subjects in The Johns Hopkins Medical Institutions in 1987. Two Accutrackers and two manual observers independently recorded blood pressure with the order determined at random. The fourth observer in each sequence obtained a replicate measurement. For both systolic and diastolic blood pressures, the mean difference between Accutracker and manual measurements was less than 3 mmHg for each pairwise comparison. Scatter plots and regression analyses demonstrated that both Accutrackers tended to underestimate high systolic and diastolic blood pressures. In bivariate and murtivariate analyses, increased age was significantly associated with underestimation of systolic blood pressures by both Accutrackers. With respect to the precision of blood pressure measurement, no significant differences were present among the four observers. In summary, our data suggest that the Accutracker has satisfactory accuracy and precision, but that accuracy is not uniform across patient subgroups. © 1990 by The Johns Hopkins University School of Hygiene and Public Health.
引用
收藏
页码:343 / 354
页数:12
相关论文
共 50 条
  • [1] CLINICAL VALIDATION OF THE ACCUTRACKER AMBULATORY BLOOD-PRESSURE MONITOR
    WHITE, WB
    SCHULMAN, P
    MCCABE, EJ
    NARDONE, M
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 1987, 41 (02) : 191 - 191
  • [2] ACCUTRACKER - EVALUATIONS OF A NEW AMBULATORY BLOOD-PRESSURE MONITOR
    NORTHCOTE, RJ
    MCKILLOP, G
    WOSORNU, D
    KESSON, E
    BROWN, JJ
    AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1990, 4 (05): : 276 - 281
  • [3] EVALUATION OF THE SUNTECH ACCUTRACKER - A NOVEL NONINVASIVE AMBULATORY BLOOD-PRESSURE MONITOR
    NELSON, KS
    WEBER, RR
    ELLIOTT, WJ
    ZEBRAUSKAS, D
    MURPHY, MB
    AMERICAN JOURNAL OF HYPERTENSION, 1988, 1 (03) : S121 - S123
  • [4] A CLINICAL-EVALUATION OF THE ACCUTRACKER - A LIGHTWEIGHT AMBULATORY BLOOD-PRESSURE MONITOR
    PHILLIPS, DIW
    BRAITHWAITE, J
    NEWCOMBE, RG
    LAZARUS, JH
    JOURNAL OF HUMAN HYPERTENSION, 1989, 3 (06) : 463 - 465
  • [5] ACCURACY OF THE TAKEDA TM-2420 AMBULATORY BLOOD-PRESSURE MONITOR
    RUSSELL, AE
    TONKIN, AL
    WING, LMH
    HASSAM, RM
    MCRITCHIE, RJ
    AYLWARD, PE
    MINSON, RB
    BUNE, AJC
    WEST, MJ
    CHALMERS, JP
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1989, 16 (04) : 253 - 256
  • [6] AMBULATORY BLOOD-PRESSURE MONITOR AND ANALYZER
    HILLMAN, D
    OTSUKA, K
    HALBERG, F
    CHRONOBIOLOGIA, 1990, 17 (04) : 305 - 313
  • [7] EVALUATION OF THE ACCUTRACKER, A NON-INVASIVE AMBULATORY BLOOD-PRESSURE RECORDER
    MCGRATH, BP
    SYME, S
    BLAKE, D
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1988, 18 (03): : 366 - 366
  • [8] CLINICAL VALIDATION OF THE ACCUTRACKER, A NOVEL AMBULATORY BLOOD-PRESSURE MONITOR USING R-WAVE GATING FOR KOROTKOFF SOUNDS
    WHITE, WB
    SCHULMAN, P
    MCCABE, EJ
    NARDONE, MB
    JOURNAL OF CLINICAL HYPERTENSION, 1987, 3 (04): : 500 - 509
  • [9] CLINICAL-EVALUATION OF THE ACCUTRACKER-II AMBULATORY BLOOD-PRESSURE MONITOR - ASSESSMENT OF PERFORMANCE IN 2 COUNTRIES AND COMPARISON WITH SPHYGMOMANOMETRY AND INTRAARTERIAL BLOOD-PRESSURE AT REST AND DURING EXERCISE
    WHITE, WB
    LUNDJOHANSEN, P
    MCCABE, EJ
    OMVIK, P
    JOURNAL OF HYPERTENSION, 1989, 7 (12) : 967 - 975
  • [10] EVALUATION OF THE REPRODUCIBILITY AND ACCURACY OF AMBULATORY BLOOD-PRESSURE MONITORING USING THE TAKEDA TM-2420 AUTOMATED BLOOD-PRESSURE MONITOR
    KELLY, JJ
    HUNYOR, SN
    HO, KY
    CLINICAL AND EXPERIMENTAL HYPERTENSION, 1993, 15 (02) : 271 - 287