Perceptions of fatigue and neuromuscular measures of performance fatigability during prolonged low-intensity elbow flexions

被引:0
|
作者
Marzouk, Monica [1 ]
McKeown, Daniel J. [1 ]
Borg, David N. [2 ,3 ]
Headrick, Jonathon [1 ]
Kavanagh, Justin J. [1 ]
机构
[1] Griffith Univ, Menzies Hlth Inst Queensland, Neural Control Movement Lab, Gold Coast, Qld, Australia
[2] Queensland Univ Technol, Australian Ctr Hlth Serv Innovat, Brisbane, Qld, Australia
[3] Queensland Univ Technol, Ctr Healthcare Transformat, Sch Publ Hlth & Social Work, Brisbane, Qld, Australia
关键词
electromyography; fatigue; predictive modelling; transcranial magnetic stimulation;
D O I
暂无
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
New FindingsWhat is the central question of this study?What is the predictive relationship between self-reported scales to quantify perceptions of fatigue during exercise and gold standard measures used to quantify the development of neuromuscular fatigue?What is the main finding and its importance?No scale was determined to be substantively more effective than another. However, the number of ongoing contractions performed was shown to be a better predictor of fatigue in the motor system than any of the subjective scales. The purpose of this study was to determine the relationship between transcranial magnetic stimulation (TMS) measures of performance fatigability and commonly used scales that quantify perceptions of fatigue during exercise. Twenty healthy participants (age 23 +/- 3 years, 10 female) performed 10 submaximal isometric elbow flexions at 20% maximal voluntary contraction (MVC) for 2 min, separated by 45 s of rest. Biceps brachii muscle electromyography and elbow flexion torque responses to single-pulse TMS were obtained at the end of each contraction to assess central factors of performance fatigability. A rating of perceived exertion (RPE) scale, Omnibus Resistance scale, Likert scale, Rating of Fatigue scale and a visual analogue scale (VAS) were used to assess perceptions of fatigue at the end of each contraction. The RPE (root mean square error (RMSE) = 0.144) and Rating of Fatigue (RMSE = 0.145) scales were the best predictors of decline in MVC torque, whereas the Likert (RMSE= 0.266) and RPE (RMSE= 0.268) scales were the best predictors of electromyographic amplitude. Although the Likert (RMSE = 7.6) and Rating of Fatigue (RMSE = 7.6) scales were the best predictors of voluntary muscle activation of any scale, the number of contractions performed during the protocol was a better predictor (RMSE = 7.3). The ability of the scales to predict TMS measures of performance fatigability were in general similar. Interestingly, the number of contractions performed was a better predictor of TMS measures than the scales themselves.
引用
收藏
页数:15
相关论文
共 41 条
  • [1] Perceptions of fatigue and neuromuscular measures of performance fatigability during prolonged low-intensity elbow flexions
    Marzouk, Monica
    McKeown, Daniel J.
    Borg, David N.
    Headrick, Jonathon
    Kavanagh, Justin J.
    [J]. EXPERIMENTAL PHYSIOLOGY, 2023, 108 (03) : 465 - 479
  • [2] Enhanced serotonin availability amplifies fatigue perception and modulates the TMS-induced silent period during sustained low-intensity elbow flexions
    Thorstensen, Jacob R.
    Taylor, Janet L.
    Tucker, Murray G.
    Kavanagh, Justin J.
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 2020, 598 (13): : 2685 - 2701
  • [3] Neuromuscular Fatigue during Low-Intensity Dynamic Exercise in Combination with Externally Applied Vascular Restriction
    Karabulut, Murat
    Cramer, Joel T.
    Abe, Takashi
    Sato, Yoshiaki
    Bemben, Michael G.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S295 - S295
  • [4] SURFACE ELECTROMYOGRAPHY AND FATIGUE DURING LOW-INTENSITY EXERCISE
    HEIJBLOM, P
    HELMES, MHB
    VANDIEEN, JH
    VRIELINK, HHEO
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1994, 479P : P52 - P53
  • [5] The effect of sustained low-intensity contractions on supraspinal fatigue in human elbow flexor muscles
    Sogaard, Karen
    Gandevia, Simon C.
    Todd, Gabrielle
    Petersen, Nicolas T.
    Taylor, Janet L.
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 2006, 573 (02): : 511 - 523
  • [6] Neuromuscular fatigue following low-intensity dynamic exercise with externally applied vascular restriction
    Karabulut, Murat
    Cramer, Joel T.
    Abe, Takashi
    Sato, Yoshiaki
    Bemben, Michael G.
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2010, 20 (03) : 440 - 447
  • [7] FLUID HOMOEOSTASIS DURING PROLONGED LOW-INTENSITY WALKING ON CONSECUTIVE DAYS
    LEIPER, JB
    MCCORMICK, K
    ROBERTSON, JD
    WHITING, PH
    MAUGHAN, RJ
    [J]. CLINICAL SCIENCE, 1988, 75 (01) : 63 - 70
  • [8] Effects of BCAA Supplementation on Plasma Amino Acids and on Subjective Fatigue and Muscle Soreness during Low-Intensity Prolonged Exercise
    Yoshida, Misaki
    Tanaka, Hiroko
    Niijima, Takako
    Miyatani, Masae
    Miyachi, Motohiko
    Tabata, Izumi
    Fujii, Yasuhiro
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S404 - S404
  • [9] Neuromuscular fatigue following high versus low-intensity eccentric exercise of biceps brachii muscle
    Gauche, Elodie
    Couturier, Antoine
    Lepers, Romuald
    Michaut, Anne
    Rabita, Giuseppe
    Hausswirth, Christophe
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2009, 19 (06) : E481 - E486