Error Characteristics of Clamp-on Ultrasonic Flowmeters Depending on Location of Sensors and Downstream Straight Run of Bent Pipe

被引:2
|
作者
Lee, Dong Keun [1 ]
Cho, Yong [1 ]
机构
[1] Korea Water Resources Corp, Seoul, South Korea
关键词
Clamp-on Type; Ultrasonic Flowmeter; Straight Run; Flow Disturbance; Intrinsic Error; Double Bent Pipe; Flying Start and Finish Method; Uncertainty;
D O I
10.3795/KSME-B.2011.35.8.861
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Flowmeters that measure the amount of fluid passing through conduits must kept accurate by comparison and the periodic calibration. The reference meters used are clamp-on meters that mount sensors on the outer wall of the pipe. They are called 1-path, 2-path or 4-path flowmeters depending on the number of sensors. We selected a flowmeter mainly used for K-water as test a flowmeter. We carried out experiments to find the intrinsic error of the flowmeter and errors in the downstream of a double bent pipe. The results show that there are the sensor locations that meet the tolerance. We suggested the angle of the sensor, the straight run from the downstream of the bent pipe and the number of sensors. So it is possible to improve the water treatment process and increase the accounted water rate by upgraded flow measurement technology.
引用
收藏
页码:861 / 868
页数:8
相关论文
共 4 条
  • [1] The Effect of Internal Pipe Wall Roughness on the Accuracy of Clamp-On Ultrasonic Flowmeters
    Gu, Xiaotang
    Cegla, Frederic
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (01) : 65 - 72
  • [2] Linearity error in Clamp-on ultrasonic flowmeters due to the installation on pipes made of dispersive materials
    Millan-Blasco, Oliver
    Salazar, Jordi
    Chavez, Juan A.
    Turo, Antoni
    Garcia-Hernandez, Miguel J.
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 1515 - 1519
  • [3] Zero-Flow Offset Variation in Ultrasonic Clamp-On Flowmeters Due to Inhomogeneity and Nonlinearity of Pipe Materials
    Millan-Blasco, Oliver
    Salazar, Jordi
    Chavez, Juan A.
    Turo-Peroy, Antoni
    Garcia-Hernandez, Miguel J.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (11) : 2845 - 2851
  • [4] Correlation Analysis of Flow Characteristics Downstream of a Double Bent Pipe and Mounting Positions of Ultrasonic Flowmeter
    Lee, Dong Keun
    Cho, Yong
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2013, 37 (11) : 1037 - 1046