CHARACTERIZATION OF LEUCINE-ZIPPER COMPLEXES BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY

被引:31
|
作者
WENDT, H
DURR, E
THOMAS, RM
PRZYBYLSKI, M
BOSSHARD, HR
机构
[1] UNIV ZURICH,INST BIOCHEM,CH-8057 ZURICH,SWITZERLAND
[2] UNIV CONSTANCE,FAK CHEM,D-78434 CONSTANCE,GERMANY
[3] ETH ZENTRUM,INST POLYMERE,CH-8092 ZURICH,SWITZERLAND
关键词
COILED COIL; ELECTROSPRAY IONIZATION MASS SPECTROMETRY; FLUORESCENCE QUENCHING; LEUCINE ZIPPER; SEDIMENTATION EQUILIBRIUM; TRANSCRIPTION FACTOR;
D O I
10.1002/pro.5560040814
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The development of ''soft'' ionization methods has enabled the mass spectrometric analysis of higher-order structural features of proteins. We have applied electrospray ionization mass spectrometry (ESI-MS) to the analysis of the number and composition of polypeptide chains in homomeric and heteromeric leucine zippers. In comparison with other methods that have been used to analyze leucine zippers, such as analytical ultracentrifugation, gel chromatography, or electrophoretic band shift assays, ESI-MS is very fast and highly sensitive and provides a straightforward way to distinguish between homomeric and heteromeric coiled-coil structures. ESI-MS analyses were carried out on the parallel dimeric leucine zipper domain GCN4-p1 of the yeast transcription factor GCN4 and on three synthetic peptides with the sequences Ac-EYEALEKKLAAX(1)EAKX(2)QALEKKLEALEHG-amide: peptide LZ (X(1),X(2) = Leu), peptide LZ(12A) (X(1) = Ala, X(2) = Leu), and peptide LZ(16N) (X(1) = Leu, X(2) = Asn). Equilibrium ultracentrifugation analysis showed that LZ forms a trimeric coiled coil and this could be confirmed unequivocally by ESI-MS as could the dimeric nature of GCN4-p1. The formation of heteromeric two- and three stranded leucine zippers composed of chains from LZ and LZ(12A), or from GCN4-p1 and LZ, was demonstrated by ESI-MS and confirmed by fluorescence quenching experiments on fluorescein-labeled peptides. The results illustrate the adaptability and flexibility of the leucine zipper motif, properties that could be useful to the design of specific protein assemblies by way of coiled-coil domains.
引用
收藏
页码:1563 / 1570
页数:8
相关论文
共 50 条
  • [1] ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    EDMONDS, CG
    SMITH, RD
    [J]. METHODS IN ENZYMOLOGY, 1990, 193 : 412 - 431
  • [2] STUDYING PROTEIN COMPLEXES WITH ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    LOO, JA
    HU, PF
    LOO, RRO
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 102 - ANYL
  • [3] CHARACTERIZATION OF BACTERIAL PHOSPHOLIPIDS BY ELECTROSPRAY-IONIZATION TANDEM MASS-SPECTROMETRY
    SMITH, PBW
    SNYDER, AP
    HARDEN, CS
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (11) : 1824 - 1830
  • [4] CHARACTERIZATION OF HAPTEN BINDING TO IMMUNOCONJUGATES BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    STRAUB, KM
    LEVY, MJ
    [J]. BIOCONJUGATE CHEMISTRY, 1994, 5 (03) : 194 - 198
  • [5] HEMOGLOBIN ANALYSIS BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    WHITE, EL
    UHRIG, MS
    REED, EA
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 63 - ANYL
  • [6] OBSERVATION OF LARGE SUBUNIT PROTEIN COMPLEXES BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    LOO, JA
    [J]. JOURNAL OF MASS SPECTROMETRY, 1995, 30 (01): : 180 - 183
  • [7] OBSERVATION OF NONCOVALENT COMPLEXES TO THE AVIDIN TETRAMER BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    SCHWARTZ, BL
    LIGHTWAHL, KJ
    SMITH, RD
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (03) : 201 - 204
  • [8] IONIZATION EFFICIENCY OF DICOPPER COMPLEX IN ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    LEE, MK
    LING, YC
    HUANG, PJ
    WANG, SM
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1994, 41 (06) : 711 - 717
  • [9] ANALYSIS OF MODIFIED DEOXYNUCLEOSIDES BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    REDDY, DM
    IDEN, CR
    [J]. NUCLEOSIDES & NUCLEOTIDES, 1993, 12 (08): : 815 - 826
  • [10] ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF BIOTIN BINDING TO STREPTAVIDIN
    ECKART, K
    SPIESS, J
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (10) : 912 - 919