CHARACTERIZATION OF NORMAL HUMAN BONE-MARROW BY FLOW-CYTOMETRY

被引:0
|
作者
BLANC, C
LEGAC, E
BINET, JL
MICHEL, A
DEBRE, P
MERLEBERAL, H
机构
[1] HOP LA PITIE SALPETRIERE,IMMUNOL CELLULAIRE LAB,47 BD HOP,F-75013 PARIS,FRANCE
[2] HOP LA PITIE SALPETRIERE,DEPT HEMATOL,F-75013 PARIS,FRANCE
来源
关键词
NORMAL BONE MARROW CELLS; FLOW CYTOMETRY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fifteen bone marrow samples were obtained from consenting donors for allogenic bone marrow transplantation and were studied by flow cytometry. The simultaneous analysis, cell by cell, of size (forward angle light scattering), structure (right angle light scattering), structure (right angle light scattering) and surface antigenic expression with 20 monoclonal antibodies allowed selection of ten reproducible cell subsets which were sorted and studied by microscopic examination in order to confirm their distinct characteristics. This very accurate analysis of a bone marrow cytogram should find applications in view of a better characterization of normal and pathological human bone marrow.
引用
收藏
页码:231 / 235
页数:5
相关论文
共 50 条
  • [1] FLOW-CYTOMETRY AND BONE-MARROW TRANSPLANTATION
    LAMY, B
    HERVE, P
    RACADOT, E
    COFFE, C
    PETERS, A
    [J]. BIOLOGY OF THE CELL, 1985, 55 (1-2) : A3 - A3
  • [2] PHENOTYPIC ANALYSIS OF A LARGE NUMBER OF NORMAL HUMAN BONE-MARROW SAMPLE BY FLOW-CYTOMETRY
    ANDREONI, C
    RIGAL, D
    BONNARD, M
    BERNAUD, J
    [J]. BLUT, 1990, 61 (05): : 271 - 277
  • [3] IDENTIFICATION AND CHARACTERIZATION OF PLASMA-CELLS IN NORMAL HUMAN BONE-MARROW BY HIGH-RESOLUTION FLOW-CYTOMETRY
    TERSTAPPEN, LWMM
    JOHNSEN, S
    SEGERSNOLTEN, IMJ
    LOKEN, MR
    [J]. BLOOD, 1990, 76 (09) : 1739 - 1747
  • [4] DISAGGREGATION OF BONE-MARROW SPICULES FOR STUDIES BY FLOW-CYTOMETRY
    SOMAN, S
    KAPLOW, LS
    [J]. ACTA PATHOLOGICA ET MICROBIOLOGICA SCANDINAVICA SECTION A-PATHOLOGY, 1981, : 59 - 62
  • [5] DIFFERENTIAL ANALYSIS OF ANIMAL BONE-MARROW BY FLOW-CYTOMETRY
    MARTIN, RA
    BROTT, DA
    ZANDEE, JC
    MCKEEL, MJ
    [J]. CYTOMETRY, 1992, 13 (06): : 638 - 643
  • [6] A RABBIT BONE-MARROW MODEL SYSTEM FOR EVALUATION OF CYTO-TOXICITY - CHARACTERIZATION OF NORMAL BONE-MARROW CELL-CYCLE PARAMETERS BY FLOW-CYTOMETRY
    MUIRHEAD, KA
    IRONS, RD
    BRUNS, R
    HORAN, PK
    [J]. JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1980, 28 (06) : 526 - 532
  • [7] MOUSE BONE-MARROW MICRONUCLEUS TEST USING FLOW-CYTOMETRY
    HAYASHI, M
    NORPPA, H
    SOFUNI, T
    ISHIDATE, M
    [J]. MUTAGENESIS, 1992, 7 (04) : 251 - 256
  • [8] CHARACTERIZATION OF LYMPHOCYTE-B DIFFERENTIATION IN NORMAL HUMAN-BONE MARROW USING FLOW-CYTOMETRY
    SHAH, VO
    CIVIN, CI
    LOKEN, MR
    [J]. EXPERIMENTAL HEMATOLOGY, 1986, 14 (06) : 505 - 505
  • [9] LONG-TERM CULTURE OF HUMAN BONE-MARROW .1. CHARACTERIZATION OF ADHERENT CELLS IN FLOW-CYTOMETRY
    ANDREONI, C
    MOREAU, I
    RIGAL, D
    [J]. EXPERIMENTAL HEMATOLOGY, 1990, 18 (05) : 431 - 437
  • [10] IDENTIFICATION OF ERYTHROPOIETIN SENSITIVE CELLS IN NORMAL HUMAN-BONE MARROW BY FLOW-CYTOMETRY
    HOLLANDER, Z
    NAGLER, A
    SHAH, VO
    LOKEN, MR
    [J]. EXPERIMENTAL HEMATOLOGY, 1988, 16 (06) : 478 - 478