DETERMINATION OF THE SURFACE PARAMETERS FOR ASPHERIC APHAKIC LENSES

被引:4
|
作者
MEDHAT, M [1 ]
HASSAN, AF [1 ]
ELNASHAR, NF [1 ]
SALMAN, SMM [1 ]
机构
[1] HELWAN UNIV,FAC SCI,DEPT PHYS,CAIRO,EGYPT
来源
OPTICS AND LASER TECHNOLOGY | 1991年 / 23卷 / 05期
关键词
ASPHERIC APHAKIC LENSES; LENS TESTING; SCANNING; INTERFEROMETRY;
D O I
10.1016/0030-3992(91)90010-L
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Two methods are proposed for aspherical surface evaluation - scanning and interferometry. Each of these methods enables the determination of the radius of curvature at the lens vertex, the asphericity, astigmatism, rotation asymmetry, surface topography and the deviation of the surface from following the theoretically stated shape. While the scanning technique is low cost and simple, the interferometric technique (which needs optical arrangements) gives more information about the surface quality. These methods, combined with a computer, establish powerful instruments for controlling lens production.
引用
收藏
页码:308 / 313
页数:6
相关论文
共 50 条
  • [1] THE PERIPHERAL POWER OF ASPHERIC APHAKIC LENSES
    SIMONET, P
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1984, 7 (12): : 789 - 800
  • [2] LABORATORY EVALUATION OF COMMERCIAL ASPHERIC APHAKIC LENSES
    ATCHISON, DA
    SMITH, G
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1983, 60 (07): : 598 - 615
  • [3] CLINICAL-TRIAL WITH COMMERCIAL ASPHERIC APHAKIC LENSES
    ATCHISON, DA
    SMITH, G
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1984, 61 (09): : 566 - 575
  • [5] Longitudinal spherical aberration and mass of bi-aspheric aphakic rigid contact lenses
    El-Nashar, NF
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1999, 19 (05) : 441 - 445
  • [6] Effects of molding parameters on profile deviation of aspheric lenses
    Zhu, Ke-Jun
    Ouyang, Bo
    Xu, Bo-Wen
    Xu, Zhi-Qiang
    Zhang, Gao-Feng
    Surface Technology, 2018, 47 (07): : 67 - 72
  • [7] INSPECTION OF BACK SURFACE ASPHERIC CONTACT-LENSES
    DEFAZIO, AJ
    LOWTHER, GE
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1979, 56 (08): : 471 - 479
  • [8] Surface profile measurement visualization of large aspheric lenses
    Shi, Yuan
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2014, 26 (05):
  • [9] Measurement techniques for aspheric surface parameters
    Hao, Qun
    Liu, Yiming
    Hu, Yao
    Tao, Xin
    LIGHT-ADVANCED MANUFACTURING, 2023, 4 (03): : 292 - 310
  • [10] Aspheric intraocular lenses
    Kohnen, T.
    Klaproth, O. K.
    OPHTHALMOLOGE, 2008, 105 (03): : 234 - 240