INVIVO DOSIMETRY DURING PELVIC TREATMENT

被引:48
|
作者
HEUKELOM, S [1 ]
LANSON, JH [1 ]
MIJNHEER, BJ [1 ]
机构
[1] NETHERLANDS CANC INST,1066 CX AMSTERDAM,NETHERLANDS
关键词
PELVIC TREATMENT; RADIOTHERAPY; INVIVO DOSIMETRY; DOSE MEASUREMENTS; TREATMENT PLANNING;
D O I
10.1016/0167-8140(92)90017-O
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
High precision in vivo entrance and exit dose measurements have been performed with p-type diodes on patients during 8 MV X-ray irradiation of the pelvis, to investigate the accuracy of dose calculations in this region. Based on phantom measurements the accuracy of the p-type diode measuring system itself, i.e. the agreement with ionisation chamber dose measurements, was shown to be better than 0.7% while the reproducibility in the dose determination was 1.1%, 1.5% and 1.6% (1 S.D.) at the entrance point, isocentre and exit point, respectively, for the wedged lateral fields. Patient movement and the uncertainty in the diode position increased these values to 1.7%, 1.5% and 3.1% (1 S.D.) for dose determinations on patients. From the entrance and exit in vivo dose values the dose actually delivered to the isocentre was determined. For the anterior-posterior beams a good correspondence for most patients was observed at the entrance and exit point and at the isocentre between the in vivo and calculated dose values. For the wedged lateral beams a systematic deviation of about 3 % was observed. In addition to the in vivo dose measurements phantom dose measurements have been performed to quantify the accuracy of the dose calculation algorithms including the computation of the number of monitor units. These measurements also served to quantify the effects of the actual patient on the dose delivery. The measurements showed that accurate calculation of the dose requires a separation of the head and phantom scatter contribution of the output of the treatment machine. The dependence of the wedge factor on field size, depth and source-skin-distance has also to be considered for accurate dose calculations. The effect of the patient on the dose calculation is mainly related to the actual electron densities of fat and bone structures compared to water: neglecting these densities in the dose computation could yield deviations up to 8.5% for the exit point in wedged beams. Based on these results, improvements in the dose calculation algorithms and monitor unit calculation including the use of the actual electron densities will be implemented in the treatment planning procedure.
引用
收藏
页码:111 / 120
页数:10
相关论文
共 50 条
  • [1] INVIVO DOSIMETRY DURING TANGENTIAL BREAST TREATMENT
    HEUKELOM, S
    LANSON, JH
    VANTIENHOVEN, G
    MIJNHEER, BJ
    RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) : 269 - 279
  • [2] INVIVO DOSIMETRY FOR TREATMENT OF CANCER OF CERVIX
    BENARY, V
    FRIEDLAND, SS
    MAJTELES, M
    WARNER, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (01) : 655 - 656
  • [3] INVIVO DOSIMETRY DURING TOTAL-BODY IRRADIATION
    FAUSER, L
    CHRIST, G
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1985, 143 (06): : 701 - 704
  • [4] PELVIC DOSIMETRY DURING RADIOTHERAPY OF CARCINOMA OF CERVIX UTERI
    JOHANSSON, JM
    LINDSKOUG, BA
    NYSTROM, CE
    ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1969, 8 (05): : 360 - +
  • [5] INVIVO DOSIMETRY IN THE PELVIS DURING FAST-NEUTRON THERAPY
    MIJNHEER, BJ
    WIEBERDINK, T
    BATTERMANN, JJ
    BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (637): : 56 - 60
  • [6] SPAN STYLE In vivo dosimetry with n-type Isorad semiconductor diodes during pelvic treatment
    Rutonjski, L.
    Petrovic, B.
    Baucal, M.
    Teodorovic, M.
    Cudic, O.
    Basaric, B.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S706 - S707
  • [7] INVIVO DOSIMETRY FOR TBI
    CHRIST, G
    STRAHLENTHERAPIE UND ONKOLOGIE, 1987, 163 (04): : 220 - 221
  • [8] INVIVO RADIOPHOTOLUMINESCENT DOSIMETRY
    AMATO, CG
    MALSKY, SJ
    ROSWIT, B
    REID, B
    JOURNAL OF NUCLEAR MEDICINE, 1963, 4 (03) : 204 - 204
  • [9] MVCB Pelvic Surface Dosimetry
    Mallah, J.
    Mihailidis, D.
    MEDICAL PHYSICS, 2012, 39 (06) : 3744 - 3744
  • [10] In vivo dosimetry in pelvic brachytherapy
    Houlihan, Orla Anne
    Workman, Geraldine
    Hounsell, Alan R.
    Prise, Kevin M.
    Jain, Suneil
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1137):