摘要
A breast coordinate system based on physiological features is developed for multi-view analysis in mammograms. It is constructed according to the locations of nipple, pectoral muscle and the fitted breast boundary. The breast regions in mammograms are mapped into a parameter frame because of the coordinate system. Experiments are implemented on data set of Breast Cancer of Peking University People's Hospital. The performance of locating the physiological features and matching the regions of interest is evaluated. Results show that the proposed coordinate system could achieve favorable performance and facilitate the multi-view analysis in mammograms.
引用
收藏
页码:176 / 182
页数:7
相关论文
共 16 条
  • [1] Anderson B.O., Yip C.H., Smith R.A., Et al., Guideline implementation for breast healthcare in low-income and middle-income countries, Cancer, 113, pp. 2221-2243, (2008)
  • [2] Maskarinec G., Meng L., Ursin G., Ethnic differences in mammographic densities, International Journal of Epidemiology, 30, 5, pp. 959-965, (2001)
  • [3] Mencattini A., Salmeri M., Casti P., Bilateral asymmetry identification for the early detection of breast cancer, 2011 IEEE International Workshop on Medical Measurements and Applications Proceedings (MeMeA), pp. 613-618, (2011)
  • [4] Casti P., Mencattini A., Salmeri M., Et al., Masking procedures and measures of angular similarity for detection of bilateral asymmetry in mammograms, The 4th IEEE International Conference on E-Health and Bioengineering, pp. 1-4, (2013)
  • [5] Casti P., Mencattini A., Salmeri M., Et al., Analysis of structural similarity in mammograms for detection of bilateral asymmetry, IEEE Transactions on Medical Imaging, 24, 2, pp. 662-671, (2015)
  • [6] Magna G., Jayaraman S.V., Casti P., Et al., Adaptive classification model based on artificial immune system for breast cancer detection, 2015 XVIII AISEM Annual Conference, pp. 1-4, (2015)
  • [7] Li Y., Chen H., Yang Y., Et al., A bilateral analysis scheme for false positive reduction in mammogram mass detection, Computers in Biology and Medicine, 57, pp. 84-95, (2015)
  • [8] Kelder A., Zigel Y., Lederman D., Et al., A new computer-aided detection scheme based on assessment of local bilateral mammographic feature asymmetry-a preliminary evaluation, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 6394-6397, (2015)
  • [9] Wang Z., Wang P., Yu G., Et al., Breast tumor detection on fusion of bilateral feature, Journal of Computer-Aided Design & Computer Graphics, 27, 6, pp. 1024-1031, (2015)
  • [10] Cao L., Chen H., Li J., Et al., A coordinate system for multi-view analysis of mammograms, The 6th International Conference on Mechanical and Electronics Engineering, pp. 481-487, (2014)