APPLICATION OF LASER-DOPPLER FLOWMETRY TO THE MEASUREMENT OF CORTICAL AND PAPILLARY PERFUSION IN THE KIDNEY OF ANESTHETIZED RAT

被引:0
|
作者
HUANG, C [1 ]
DAVIS, G [1 ]
JOHNS, EJ [1 ]
机构
[1] UNIV BIRMINGHAM,DEPT PHYSIOL,BIRMINGHAM B15 2TT,W MIDLANDS,ENGLAND
来源
关键词
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
引用
收藏
页码:P11 / P11
页数:1
相关论文
共 50 条
  • [1] MEASUREMENT OF PANCREAS PARENCHYMA PERFUSION BY LASER-DOPPLER FLOWMETRY
    NORSTEIN, J
    LIEN, B
    HALL, C
    KVERNEBO, K
    MORKRID, L
    SOREIDE, O
    BREKKE, IB
    FLATMARK, A
    TRANSPLANTATION PROCEEDINGS, 1990, 22 (02) : 607 - 608
  • [2] EFFECTS OF ANGIOTENSIN ON RENAL CORTICAL AND PAPILLARY BLOOD FLOWS MEASURED BY LASER-DOPPLER FLOWMETRY
    NOBES, MS
    HARRIS, PJ
    YAMADA, H
    MENDELSOHN, FAO
    AMERICAN JOURNAL OF PHYSIOLOGY, 1991, 261 (06): : F998 - F1006
  • [3] Pulsed laser-Doppler flowmetry for monitoring deep perfusion
    Kolkman, RGM
    Hondebrink, E
    Bolt, RA
    Steenbergen, W
    de Mul, FFM
    HYBRID AND NOVEL IMAGING AND NEW OPTICAL INSTRUMENTATION FOR BIOMEDICAL APPLICATIONS, 2001, 4434 : 204 - 207
  • [4] CONTINUOUS MEASUREMENT OF CEREBRAL CORTICAL BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY IN A RAT STROKE MODEL
    DIRNAGL, U
    KAPLAN, B
    JACEWICZ, M
    PULSINELLI, W
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1989, 9 (05): : 589 - 596
  • [5] LASER-DOPPLER FLOWMETRY
    OBERG, PA
    CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 1990, 18 (02) : 125 - 163
  • [6] CONTINUOUS MONITORING OF CORTICAL PERFUSION BY LASER-DOPPLER FLOWMETRY IN VENTILATED PATIENTS WITH HEAD-INJURY
    KIRKPATRICK, PJ
    SMIELEWSKI, P
    CZOSNYKA, M
    PICKARD, JD
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1994, 57 (11): : 1382 - 1388
  • [7] LASER-DOPPLER FLOWMETRY - A NONINVASIVE METHOD FOR MICROVASCULAR PERFUSION MEASUREMENTS
    OBERG, PA
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1986, 5 (2-3): : 163 - 163
  • [8] HUMAN BRONCHIAL PERFUSION EVALUATED WITH ENDOSCOPIC LASER-DOPPLER FLOWMETRY
    SUNDSET, A
    HANSEN, G
    HAANAES, OC
    LINE, PD
    KVERNEBO, K
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1993, 13 (03): : 233 - 245
  • [9] Scanning laser-Doppler flowmetry of rat cerebral circulation during cortical spreading depression
    Nielsen, AN
    Fabricius, M
    Lauritzen, M
    JOURNAL OF VASCULAR RESEARCH, 2000, 37 (06) : 513 - 522
  • [10] DIAPHRAGMATIC MICROCIRCULATION MEASURED BY LASER-DOPPLER FLOWMETRY IN THE RAT
    CHANG, HY
    CHEN, CR
    HUSSAIN, SNA
    JOURNAL OF APPLIED PHYSIOLOGY, 1995, 78 (04) : 1225 - 1233