SINGLE-PULSE, 2-LINE TEMPERATURE-MEASUREMENT TECHNIQUE USING KRF LASER-INDUCED O-2 FLUORESCENCE

被引:12
|
作者
GRINSTEAD, JH [1 ]
LAUFER, G [1 ]
MCDANIEL, JC [1 ]
机构
[1] UNIV VIRGINIA,AEROSP RES LAB,CHARLOTTESVILLE,VA 22903
来源
APPLIED OPTICS | 1995年 / 34卷 / 24期
关键词
LASER-INDUCED FLUORESCENCE; O-2; TEMPERATURE MEASUREMENT; SINGLE PULSE; KRF LASER;
D O I
10.1364/AO.34.005501
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new single-pulse, two-line laser-induced O-2 fluorescence (LIF) temperature-measurement technique was demonstrated. The fluorescence spectrum obtained with multichannel detection following simultaneous excitation of two coincident transitions in the 0-6 and the 2-7 bands of the B (3) Sigma(u)(-)-X(3) Sigma(g)(-) Schumann-Runge system was used to determine the gas temperature. The rms error of 100-pulse average LIF temperature measurements, referenced to their corresponding thermocouple measurements, was 1.3% over a temperature range of 1300-1800 K in atmospheric air. Photon shot noise was found to be the primary source of uncertainty for these measurements in a quiescent environment. Single-pulse-temperature-measurement uncertainties(1 sigma) ranged from approximately 13% at 1300 K to 7% at 1800 K.