A novel approach to stethoscope hygiene: A coat-pocket innovation

被引:7
|
作者
Messina, Gabriele [1 ,2 ]
Spataro, Giuseppe [2 ]
Rosadini, Daniele [2 ]
Burgassi, Sandra [1 ]
Mariani, Lorenzo [3 ]
Tani, Marco [4 ]
Cevenini, Gabriele [5 ]
机构
[1] Univ Siena, Dept Mol & Dev Med, Via Aldo Moro 2, I-53100 Siena, Italy
[2] Univ Siena, Post Grad Sch Publ Hlth, Via Aldo Moro 2, I-53100 Siena, Italy
[3] Hosp Direct, Rugani Clin, Str Reg 222, I-53035 Siena, Italy
[4] FeT Elettron Snc, Via A Volta 28, I-53036 Siena, Italy
[5] Univ Siena, Dept Med Biotechnol, Viale Mario Bracci 16, I-53100 Siena, Italy
关键词
Disinfection; UV-C; Stethoscope; Healthcare-associated infection;
D O I
10.1016/j.idh.2018.06.002
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The stethoscope is the most widely used instrument in healthcare. Studies have found similar rates of contamination on the stethoscope diaphragm and on physician fingertips after a single examination. Our aim was to test the effectiveness of an innovative portable device for disinfecting stethoscope membranes. Methods: From November 2016 to May 2017, a cross-sectional study was conducted in four wards of a private clinic: General Ward (GW), Internal Medicine Ward (IMW), Post-Operative Observation Ward (POW) and Permanent Vegetative State Ward (PVSW). Five wearable medical devices, designed to disinfect stethoscope membranes automatically by means of UV-C radiation, were provided to operators. Spot checks were made for microbial counts of stethoscope membranes, classified as treated or otherwise on the basis of whether they were found coupled or otherwise with the devices. The percentage reduction in colony forming units (CFU) was calculated between the two groups. Results: The number of tests of stethoscopes treated with the device was 116 out of 272. Untreated samples had a mean contamination of 132.2 CFU versus 6.9 CFU of treated samples: a 94.8% reduction (95% CI 91.3%-97.7). Highly significant statistical differences in CFU were found between untreated and treated membranes (p < 0.001). In particular, microbial contamination showed a reduction of 88.7% (CI 77.5%-96.05%) in PVSW, 95.9% (CI 88.2%-98.5%) in GW, 84.5% (CI 76.4%-90.5%) in IMW and 95.8% (CI 90.3%-98.1%) in POW. Conclusion: The devices proved effective and efficient in reducing the microbial load of stethoscope membranes. Wearing the device on the coat may act as a reminder of the need for hygiene. (C) 2018 Australasian College for Infection Prevention and Control. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:211 / 216
页数:6
相关论文
共 50 条
  • [1] Point of Care Stations: A Novel Way to Improve Stethoscope Hygiene
    Gibbens, Kimberly
    Hota, Susy
    Seidelin, Peter
    Rebelo, Carly
    Ross, Kathleen
    Vaisman, Alon
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2020, 41 : S493 - S494
  • [2] Novel Approach to the Diagnosis of Fractures in an Austere Environment Using a Stethoscope and a Cellular Phone
    Matzek, Brett A.
    Fivecoat, Phillip T.
    Ritz, Reis B.
    [J]. WILDERNESS & ENVIRONMENTAL MEDICINE, 2014, 25 (01) : 99 - 102
  • [3] Phosphorescent wax - The novel approach of innovation
    Devi, N. Sanjana
    Veeraiyan, Deepak Nallaswamy
    Sivaswamy, Vinay
    Maiti, Subhabrata
    Ganapathy, Dhanraj M.
    Rajaraman, Vaishnavi
    [J]. JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 : S496 - S499
  • [4] Quantitative Comparison of Pocket Geometry and Pocket Decomposition to Obtain Improved Spiral Tool Path: A Novel Approach
    Patel, Divyangkumar D.
    Lalwani, Devdas I.
    [J]. JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2017, 139 (03):
  • [5] A novel approach to improve hand hygiene compliance of student nurses
    Salmon, Sharon
    Wang, Xiao Bei
    Seetoh, Theresa
    Lee, Siu Yin
    Fisher, Dale A.
    [J]. ANTIMICROBIAL RESISTANCE AND INFECTION CONTROL, 2013, 2
  • [6] A novel approach to improve hand hygiene compliance of student nurses
    Sharon Salmon
    Xiao Bei Wang
    Theresa Seetoh
    Siu Yin Lee
    Dale A Fisher
    [J]. Antimicrobial Resistance and Infection Control, 2
  • [7] Phosphorescent wax-The novel approach of innovation
    Devi, N. Sanjana
    Veeraiyan, Deepak Nallaswamy
    Sivaswamy, Vinay
    Maiti, Subhabrata
    Ganapathy, Dhanraj M.
    Rajaraman, Vaishnavi
    [J]. JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 (06) : 496 - 499
  • [8] Innovation nudging-A novel approach to foster innovation engagement in an incumbent company
    Stieler, Maximilian
    Henike, Tassilo
    [J]. CREATIVITY AND INNOVATION MANAGEMENT, 2022, 31 (01) : 35 - 48
  • [9] A novel approach for predicting global innovation index scores
    Yildirim, Rabia Sultan
    Ukelge, Mulayim Ongun
    Essiz, Esra Sarac
    Oturakci, Murat
    [J]. INTERNATIONAL JOURNAL OF APPLIED MANAGEMENT SCIENCE, 2024, 16 (03)
  • [10] Fibre retention osseous resective surgery: a novel conservative approach for pocket elimination
    Carnevale, Gianfranco
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (02) : 182 - 187