Sandwich-type electrochemical aptasensor based on Au-modified conductive octahedral carbon architecture and snowflake-like PtCuNi for the sensitive detection of cardiac troponin I

被引:0
|
作者
Chen, Kaicha [1 ]
Zhao, Hongli [1 ]
Wang, Zhenxing [1 ]
Zhou, Fangfang [1 ]
Shi, Zehui [1 ]
Cao, Shida [1 ]
Lan, Minbo [1 ,2 ]
机构
[1] East China Univ Sci & Technol, Sch Chem & Mol Engn, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
[2] East China Univ Sci & Technol, Res Ctr Anal & Test, Shanghai 200237, Peoples R China
来源
关键词
Cardiac troponin I; Conductive carbon; Snowflake PtCuNi; Electrochemical aptasensor;
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The cardiac troponin I (cTnI) detection is increasingly significant given its promising value in the clinical acute myocardial infarction diagnosis. Here a sensitive sandwich-type cTnI electrochemical aptasensor was developed by using zirconium-carbon loaded with Au (Au/Zr-C) as electrode-modified material and snowflake-like PtCuNi catalyst as label material. The Au/Zr-C was prepared from a carbonation process and a reduction step. The PtCuNi was synthesized by a one-pot hydrothermal reaction. On the one hand, due to its many merits of large effective area, rich pores, high degree of graphitization, the assistance of Au, the Au/Zr-C exhibited remarkable electronic conductivity but low catalytical capacity, thus improving the electrochemical property but lowing the background signal of electrode. On the other hand, because of its accessible active sites of the special snowflake-like structure and the synergy of three elements, the PtCuNi catalyst presented excellent catalytic activity and improved stability compared to binary alloy. The recognition reactions were achieved by stepwise incubation of aptamer 1, cTnI, and aptamer 2-PtCuNi (denoted as Apt2-label) on the Au/Zr-C-modified electrode. The electrocatalytic signals of the immobilized Apt2-label towards the H2O2 reduction were recorded in all tests for cTnI analysis. Consequently, this cTnI aptasensor exhibited excellent performance involving a wide linear range of 100 ng mL-1 to 0.01 pg mL(-1) with a detection limit of 1.24 x 10(-3) pg mL(-1) (S/N = 3), good selectivity, satisfying reproducibility, outstanding stability, and good recovery.
引用
收藏
页数:10
相关论文
共 33 条
  • [1] Sandwich-type electrochemical aptasensor based on Au-modified conductive octahedral carbon architecture and snowflake-like PtCuNi for the sensitive detection of cardiac troponin I
    Chen, Kaicha
    Zhao, Hongli
    Wang, Zhenxing
    Zhou, Fangfang
    Shi, Zehui
    Cao, Shida
    Lan, Minbo
    [J]. BIOSENSORS & BIOELECTRONICS, 2022, 212
  • [2] Sandwich-type electrochemical aptasensor based on Au-modified conductive octahedral carbon architecture and snowflake-like PtCuNi for the sensitive detection of cardiac troponin I
    Chen, Kaicha
    Zhao, Hongli
    Wang, Zhenxing
    Zhou, Fangfang
    Shi, Zehui
    Cao, Shida
    Lan, Minbo
    [J]. Biosensors and Bioelectronics, 2022, 212
  • [3] Sandwich-type electrochemical aptasensor based on polydopamine-Au-metal ions as signal label and coralloid Au-conductive carbon architecture-modified electrode for the simultaneous detection of cardiac troponin I and myoglobin
    Chen, Kaicha
    Zhao, Hongli
    Wang, Zhenxing
    Zhou, Fangfang
    Lan, Minbo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2023, 390
  • [4] Electrochemical Sandwich-Type Aptasensor Based on the Multifunctional Catechol-Loaded Au/MIL-53(Fe) for Detection of Cardiac Troponin I
    Momeni, Fatemeh
    Khoshfetrat, Seyyed Mehdi
    Zarei, Kobra
    [J]. ACS APPLIED NANO MATERIALS, 2023, 6 (20) : 19239 - 19248
  • [5] Amperometric aptasensor with sandwich-type architecture for troponin I based on carboxyethylsilanetriol-modified graphene oxide coated electrodes
    Villalonga, Anabel
    Estabiel, Itziar
    Perez-Calabuig, Ana M.
    Mayol, Beatriz
    Parrado, Concepcion
    Villalonga, Reynaldo
    [J]. BIOSENSORS & BIOELECTRONICS, 2021, 183
  • [6] A sensitive sandwich-type electrochemical aptasensor for thrombin detection based on platinum nanoparticles decorated carbon nanocages as signal labels
    Gao, Fenglei
    Du, Lili
    Zhang, Yu
    Zhou, Fuyi
    Tang, Daoquan
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 86 : 185 - 193
  • [7] A novel sandwich-type electrochemical aptasensor for sensitive detection of kanamycin based on GR-PANI and PAMAM-Au nanocomposites
    Xu, Wei
    Wang, Yu
    Liu, Su
    Yu, Jinghua
    Wang, Hongzhi
    Huang, Jiadong
    [J]. NEW JOURNAL OF CHEMISTRY, 2014, 38 (10) : 4931 - 4937
  • [8] Triple signal-enhancing sandwich-type electrochemical immunosensor based on Au@SNHC and PtPdCu/BNC for detection of Cardiac Troponin I
    Zhang, Xuelin
    Shang, Qing
    Jiang, Feng
    Dong, Hui
    Li, Yueyuan
    Wang, Shujun
    Tang, Feng
    Liu, Qing
    Li, Yueyun
    Wei, Qin
    [J]. BIOELECTROCHEMISTRY, 2023, 154
  • [9] Sandwich-type electrochemical aptasensor based on hollow mesoporous carbon spheres loaded with porous dendritic Pd@Pt nanoparticles as signal amplifier for ultrasensitive detection of cardiac troponin I
    Wang, Zhenxing
    Zhao, Hongli
    Chen, Kaicha
    Li, Hongyuan
    Lan, Minbo
    [J]. ANALYTICA CHIMICA ACTA, 2021, 1188
  • [10] Sandwich-type electrochemical immunosensor based on CuFe2O4-Pd for cardiac troponin I detection
    Meng, Yaoyao
    Li, Yueyuan
    Liu, Shanghua
    Wang, Shujun
    Dong, Hui
    Jiang, Feng
    Liu, Qing
    Li, Yueyun
    Wei, Qin
    [J]. MICROCHIMICA ACTA, 2023, 190 (06)