A BIOMECHANICAL EVALUATION OF AN INTRAMEDULLARY FIXATION DEVICE FOR INTERTROCHANTERIC FRACTURES

被引:16
|
作者
FLAHIFF, CM [1 ]
NELSON, CL [1 ]
GRUENWALD, JM [1 ]
HOLLIS, JM [1 ]
机构
[1] UNIV ARKANSAS MED SCI HOSP,DEPT ORTHOPAED SURG,4301 W MARKHAM ST,MAIL SLOT 531,LITTLE ROCK,AR 72205
关键词
D O I
10.1097/00005373-199307000-00004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The strength and stability of an intramedullary device when used to fix intertrochanteric fractures were determined and compared with the dynamic hip screw (DHS). A standard four-part osteotomy was created in eight paired fresh frozen human cadaver femurs. The intramedullary fixation device and a DHS were implanted in each pair member, and mechanical testing was performed. Micromotion was measured during cyclic loading to determine implant stability, and then the specimens were loaded to failure. The intramedullary fixation device had significantly greater stability in cyclic loading than the DHS and required more than twice the force for failure. For patients with osteoporosis, this device may be a useful alternative to standard sliding nail systems.
引用
收藏
页码:23 / 27
页数:5
相关论文
共 50 条
  • [1] Biomechanical Evaluation of Extramedullary Versus Intramedullary Fixation for Reverse Obliquity Intertrochanteric Fractures
    Kuzyk, Paul R. T.
    Lobo, Joel
    Whelan, Daniel
    Zdero, Rad
    McKee, Michael D.
    Schemitsch, Emil H.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (01) : 31 - 38
  • [2] STABLE FIXATION OF INTERTROCHANTERIC FRACTURES - BIOMECHANICAL EVALUATION
    KAUFER, H
    MATTHEWS, LS
    SONSTEGARD, D
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (05): : 899 - 907
  • [3] STABLE FIXATION IN INTERTROCHANTERIC HIP FRACTURES - BIOMECHANICAL EVALUATION
    SONSTEGA.DA
    MATTHEWS, LS
    KAUFER, H
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (03): : 660 - &
  • [4] Controversies in Intramedullary Fixation for Intertrochanteric Hip Fractures
    Baldwin, Paul C., III
    Lavender, Randy C.
    Sanders, Roy
    Koval, Kenneth J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (12) : 635 - 641
  • [6] A CONTOURED DEVICE FOR FIXATION OF INTERTROCHANTERIC FRACTURES
    HUBBARD, KT
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1962, 44 (06): : 1170 - 1176
  • [7] BIOMECHANICAL AND CLINICAL-EVALUATION OF THE EXPANDABLE INTRAMEDULLARY FIXATION DEVICE
    NORDYKE, MD
    LEWIS, RC
    JANSSEN, HF
    DUNCAN, KH
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (01): : 128 - 134
  • [8] Biomechanical study of extramedullary and intramedullary fixation in the treatment of unstable intertrochanteric reversed-tilt fractures of the femur
    Lu, Guo-Liang
    Li, Song-Jun
    Li, Wen-Xue
    ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (04)
  • [9] Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures
    Baumgaertner, MR
    Curtin, SL
    Lindskog, DM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (348) : 87 - 94
  • [10] Intramedullary Fixation of Intertrochanteric Fractures with the Proximal Femoral Nail (PFN)
    Akhil P. Verheyden
    Christoph Josten
    European Journal of Trauma, 2004, 30 (3): : 197 - 206