Role of the monocyte-to-high-density lipoprotein ratio in predicting atrial high-rate episodes detected by cardiac implantable electronic devices

被引:5
|
作者
Satilmis, Seckin [1 ]
机构
[1] Acibadem Atakent Univ Hosp, Dept Cardiol, Istanbul, Turkey
关键词
Atrial high-rate episodes; cardiac implantable electronic devices; monocyte-to-high-density lipoprotein ratio; inflammation; oxidative stress;
D O I
10.14744/nci.2017.35761
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: Technological advances have allowed cardiac implantable electronic devices (CIEDs) to detect, analyze, and store atrial high-rate episodes (AHREs), which are surrogate for the term silent atrial fibrillation (AF). The association of AHREs with adverse clinical events has been demonstrated in several recent studies, implying that morbidity and mortality can be significantly prevented by prompt recognition and intervention. Inflammation and oxidative stress are among several mechanisms that contribute to the pathogenesis of AF. The monocyte-to-high-density lipoprotein ratio (M/H ratio) is a novel indicator of both inflammation and oxidative stress. In this study, we aimed to investigate the value of the M/H ratio for predicting AHREs detected by CIEDs. METHODS: A total of 203 patients (mean age: 57.5+9.1 years, 60.1% male) implanted with a dual pacemaker because of sick sinus syndrome were included. Blood samples were obtained from the patients after 12 h of fasting for the analysis of routine biochemistry tests and the lipid panel in the morning of device implantation. At a clinical visit 6 months after CIED implantation, the devices were interrogated to detect the occurrence of AHREs. AHREs were defined as atrial episodes faster than 220 bpm and lasting longer than 5 min. The patients were divided into two groups depending on the presence of AHREs during pacemaker interrogation: Group 1 (AHRE present) and Group 2 (AHRE absent). RESULTS: At the clinical visit 6 months after CIED implantation, 51 (25.1%) patients had at least one AHRE. The M/H ratio was significantly higher in patients in Group 1 (11.41 +/- 1.24) than in those in Group 2 (8.17 +/- 1.02) (p<0.01). On performing multivariate Cox regression analysis, the M/H ratio was found to be associated with the occurrence of AHREs in patients with CIEDs (OR: 22.813, 95% CI: 6.852-75.953, p<0.01). CONCLUSION: The M/H ratio is an indicator of inflammation and oxidative stress, both of which play an important role in the pathogenesis of AF. This ratio was found to be statically higher in patients with AHREs detected by CIEDs than in those without AHREs.
引用
收藏
页码:96 / 101
页数:6
相关论文
共 50 条
  • [1] Anticoagulation in Patients with Atrial High-rate Episodes Detected by Cardiac Implantable Electronic Devices
    Spartalis, Michael
    Kontogiannis, Christos
    Spartalis, Eleftherios
    Iliopoulos, Dimitrios C.
    Siasos, Gerasimos
    CURRENT PHARMACEUTICAL DESIGN, 2024, 30 (07) : 485 - 488
  • [2] Atrial High-Rate Episodes Detected by Cardiac Implantable Electronic Devices: Dynamic Changes in Episodes and Predictors of Incident Atrial Fibrillation
    Imberti, Jacopo Francesco
    Bonini, Niccolo
    Tosetti, Alberto
    Mei, Davide Antonio
    Gerra, Luigi
    Malavasi, Vincenzo Livio
    Mazza, Andrea
    Lip, Gregory Y. H.
    Boriani, Giuseppe
    BIOLOGY-BASEL, 2022, 11 (03):
  • [3] Management of atrial high-rate episodes detected by cardiac implanted electronic devices
    Freedman, Ben
    Boriani, Giuseppe
    Glotzer, Taya V.
    Healey, Jeff S.
    Kirchhof, Paulus
    Potpara, Tatjana S.
    NATURE REVIEWS CARDIOLOGY, 2017, 14 (12) : 701 - 714
  • [4] Management of atrial high-rate episodes detected by cardiac implanted electronic devices
    Ben Freedman
    Giuseppe Boriani
    Taya V. Glotzer
    Jeff S. Healey
    Paulus Kirchhof
    Tatjana S. Potpara
    Nature Reviews Cardiology, 2017, 14 : 701 - 714
  • [5] Interatrial block predicts atrial high rate episodes detected by cardiac implantable electronic devices
    Tekkesin, Ahmet Ilker
    Cinier, Goksel
    Cakilli, Yasin
    Hayiroglu, Mert Ilker
    Alper, Ahmet Taha
    JOURNAL OF ELECTROCARDIOLOGY, 2017, 50 (02) : 234 - 237
  • [6] Inflammation and the risk of atrial high-rate episodes (AHREs) in patients with cardiac implantable electronic devices
    Pastori, Daniele
    Miyazawa, Kazuo
    Li, Yanguang
    Shahid, Farhan
    Hado, Hussein
    Lip, Gregory Y. H.
    CLINICAL RESEARCH IN CARDIOLOGY, 2018, 107 (09) : 772 - 777
  • [7] Inflammation and the risk of atrial high-rate episodes (AHREs) in patients with cardiac implantable electronic devices
    Daniele Pastori
    Kazuo Miyazawa
    Yanguang Li
    Farhan Shahid
    Hussein Hado
    Gregory Y. H. Lip
    Clinical Research in Cardiology, 2018, 107 : 772 - 777
  • [8] Prevalence and Predictors of Clinically Relevant Atrial High-Rate Episodes in Patients with Cardiac Implantable Electronic Devices
    Kim, Min
    Kim, Tae-Hoon
    Yu, Hee Tae
    Choi, Eue-Keun
    Park, Hyung-Seob
    Park, Junbeom
    Lee, Young Soo
    Kang, Ki-Woon
    Shim, Jaemin
    Sung, Jung-Hoon
    Oh, Il-Young
    Joung, Boyoung
    KOREAN CIRCULATION JOURNAL, 2021, 51 (03) : 235 - 247
  • [9] Relationship between inflammation and atrial high-rate episodes (AHREs) in patients with cardiac implantable electronic devices
    Pastori, D.
    Miyazawa, K.
    Li, Y.
    Shahid, F.
    Hado, H.
    Lip, G. Y. H.
    EUROPEAN HEART JOURNAL, 2018, 39 : 401 - 401
  • [10] HATCH Score and Left Atrial Size Predict Atrial High-Rate Episodes in Patients With Cardiac Implantable Electronic Devices
    Chen, Ju-Yi
    Chen, Tse-Wei
    Lu, Wei-Da
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8