CLINICAL-APPLICATIONS OF CARBON-DIOXIDE DIGITAL SUBTRACTION ARTERIOGRAPHY

被引:62
|
作者
WEAVER, FA
PENTECOST, MJ
YELLIN, AE
DAVIS, S
FINCK, E
TEITELBAUM, G
机构
[1] STANFORD UNIV, MED CTR, SCH MED, DEPT SURG, STANFORD, CA 94305 USA
[2] STANFORD UNIV, MED CTR, SCH MED, DEPT RADIOL, STANFORD, CA 94305 USA
关键词
D O I
10.1016/0741-5214(91)90219-K
中图分类号
R61 [外科手术学];
学科分类号
摘要
During an 18-month period 33 patients in whom there were contraindications to the use of iodinated contrast arteriography underwent 40 carbon dioxide/digital subtraction arteriograms for lower extremity ischemia (19), severe hypertension and renal insufficiency (12), or arterial aneurysm (2). Contraindications to iodinated contrast agents included renal insufficiency, congestive heart failure, and contrast hypersensitivity. Sixteen aortic, 15 iliac-femoral-popliteal-tibial, five aorta-iliac-femoral and four aorta-iliac-femoral-popliteal-tibial carbon dioxide/digital subtraction arteriography studies were performed. In 11 studies, imaging of selected arterial segments required the addition of 10 to 60 ml of dilute nonionic contrast. Guided by carbon dioxide/digital subtraction arteriography studies four femoral-tibial bypasses, three aneurysmorrhaphies, two aortorenal bypasses, one aortofemoral bypass and one femoral-femoral bypass were successfully performed in 11 patients. In addition, carbon dioxide/digital subtraction arteriography directed angioplasties of the common iliac (4), superficial fermoral (6), popliteal (3), or tibioperoneal trunk (1) were performed in 10 patients. Complications of carbon dioxide/digital subtraction arteriography included transient deterioration in renal function in three patients in whom 20 ml of nonionic contrast was used, a nonfatal myocardial infarction after a popliteal percutaneous transluminal angioplasty in one patient, and transient tachypnea and tachycardia during a carbon dioxide/digital subtraction arteriography study in one patient. Diagnostic arteriograms are obtainable using carbon dioxide as the contrast agent. Carbon dioxide/digital subtraction arteriography permits patients with symptomatic arterial disease at high risk for contrast related complications to safety undergo arteriography and subsequent arterial reconstruction or endovascular intervention.
引用
收藏
页码:266 / 273
页数:8
相关论文
共 50 条
  • [1] CARBON-DIOXIDE DIGITAL SUBTRACTION ARTERIOGRAPHY-ASSISTED TRANSLUMINAL ANGIOPLASTY
    FRANKHOUSE, JH
    RYAN, MG
    PAPANICOLAOU, G
    YELLIN, AE
    WEAVER, FA
    [J]. ANNALS OF VASCULAR SURGERY, 1995, 9 (05) : 448 - 452
  • [2] DIGITAL SUBTRACTION ARTERIOGRAPHY WITH CARBON-DIOXIDE - AN ALTERNATIVE TO ARTERIOGRAPHY OF THE EXTREMITIES WITH IODINE-CONTAINING CONTRAST-MEDIA
    HESS, H
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 153 (03): : 233 - 238
  • [3] SOME CLINICAL-APPLICATIONS OF CARBON-DIOXIDE LASER IN UROLOGIC SURGERY
    ROSEMBERG, SK
    LUTZ, SJ
    [J]. UROLOGY, 1984, 23 (03) : 240 - 242
  • [4] CARBON-DIOXIDE DIGITAL SUBTRACTION ANGIOGRAPHY - EXPANDING APPLICATIONS AND TECHNICAL EVOLUTION
    KERNS, SR
    HAWKINS, IF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (03) : 735 - 741
  • [5] DIGITAL SUBTRACTION ANGIOGRAPHY - CURRENT CLINICAL-APPLICATIONS
    PELZ, DM
    FOX, AJ
    VINUELA, F
    [J]. STROKE, 1985, 16 (03) : 528 - 536
  • [6] CLINICAL-APPLICATIONS OF THE ARGON AND CARBON-DIOXIDE LASERS IN DERMATOLOGY AND PLASTIC-SURGERY
    MASER, MR
    APFELBERG, DB
    LASH, H
    [J]. WORLD JOURNAL OF SURGERY, 1983, 7 (06) : 684 - 691
  • [7] DIGITAL SUBTRACTION ANGIOGRAPHY WITH AN ISOCON CAMERA SYSTEM - CLINICAL-APPLICATIONS
    BARBARIC, ZL
    GOMES, AS
    DECKARD, ME
    NELSON, RS
    MOLER, CL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 142 (01) : 143 - 147
  • [8] CARBON-DIOXIDE DIGITAL SUBTRACTION ANGIOGRAPHY IN ONCOLOGICAL-INTERVENTIONAL RADIOLOGY
    GARBAGNATI, F
    SPREAFICO, C
    MARCHIANO, A
    FRIGERIO, LF
    PATELLI, G
    GERVASONI, M
    GIOVANNARDI, G
    DAMASCELLI, B
    [J]. TUMORI, 1995, 81 (01) : 52 - 55
  • [9] PRINCIPLE OF HIGH-SPEED DIGITAL SUBTRACTION ECHOGRAPHY AND THE POTENTIAL FOR CLINICAL-APPLICATIONS
    ISHIHARA, K
    TANOUCHI, J
    KITABATAKE, A
    KONDO, H
    UEMATSU, M
    MASUYAMA, T
    DOI, Y
    YAMAMOTO, K
    HORI, M
    KAMADA, T
    CHIHARA, K
    KISHIMOTO, S
    YOKOZAWA, N
    SASAKI, A
    OGAWA, T
    MUKAI, N
    KODAMA, M
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1991, 30 : 224 - 227
  • [10] INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY WITH CARBON-DIOXIDE - SUPERIOR DETECTABILITY OF ARTERIOVENOUS SHUNTING
    TAKEDA, T
    IDO, K
    YUASA, Y
    NISHIMURA, G
    HASHIMOTO, S
    KYO, E
    OKAWA, S
    NAKATSUKA, S
    MIURA, H
    KOBAYASHI, S
    TANAKA, T
    HIRAMATSU, K
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1988, 11 (02) : 101 - 107