NONINVASIVE MEASUREMENT OF RENAL HEMODYNAMIC FUNCTIONS USING GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING

被引:61
|
作者
DUMOULIN, CL
BUONOCORE, MH
OPSAHL, LR
KATZBERG, RW
DARROW, RD
MORRIS, TW
BATEY, C
机构
[1] GE CO,CTR ELECT RES & DEV,SCHENECTADY,NY
[2] UNIV CALIF DAVIS,SCH MED,DEPT RADIOL,SACRAMENTO,CA
[3] UNIV ROCHESTER,MED CTR,DEPT RADIOL,ROCHESTER,NY 14642
[4] ALBANY MED COLL,ALBANY,NY
关键词
MAGNETIC RESONANCE; RENAL FUNCTION;
D O I
10.1002/mrm.1910320312
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A technique for the assessment of single kidney hemodynamic functions utilizing a novel MR pulse sequence in conjunction with MR contrast material administration scribed. Renal extraction fraction (EF) is derived measuring the concentration of the incoming contrast agent in the renal artery and the outgoing concentration in the renal vein. The glomerular filtration rate (GFR) can then be determined by the product of EF and renal plasma flow. A modified inversion recovery MR pulse sequence is used to measure the T-1 of moving blood. This pulse sequence uses a spatially nonselective inversion pulse. A series of small flip angle detection pulses are then used to monitor the recovery of longitudinal spin magnetization in an image plane intersecting the renal vessels. The recovery rate is measured in each vessel and the T-1 of blood determined. These T-1 measurements are then used to determine the ratio of contrast concentration in the renal arteries and veins. Blood flow measurements can be obtained simultaneously with T-1 measurements by inserting flow-encoding magnetic field gradients into the pulse sequence. Preliminary results in human volunteers suggest the feasibility of noninvasively determining hemodynamic functions with magnetic resonance.
引用
收藏
页码:370 / 378
页数:9
相关论文
共 50 条
  • [1] NONINVASIVE MEASUREMENT OF RENAL HEMODYNAMIC FUNCTIONS USING GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING
    KATZBERG, RW
    DUMOULIN, CL
    BUONOCORE, MA
    OPSAHL, LR
    DARROW, RD
    MORRIS, TW
    [J]. INVESTIGATIVE RADIOLOGY, 1994, 29 : S123 - S126
  • [2] Noninvasive measurement of renal hemodynamic functions with gadolinium-enhanced MR imaging
    Katzberg, RW
    [J]. RADIOLOGY, 1999, 210 (01) : 287 - 288
  • [3] Noninvasive measurement of renal hemodynamic functions with gadolinium-enhanced MR imaging - Response
    Grist, TM
    Niendorf, ER
    Lee, FT
    Brazy, PC
    Santyr, GR
    [J]. RADIOLOGY, 1999, 210 (01) : 288 - 288
  • [4] GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING IN BELLS-PALSY
    SCHWABER, MK
    LARSON, TC
    ZEALEAR, DL
    CREASY, J
    [J]. LARYNGOSCOPE, 1990, 100 (12): : 1264 - 1269
  • [5] GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING IN ACUTE MYOCARDIAL-INFARCTION
    YOKOTA, C
    NONOGI, H
    MIYAZAKI, S
    GOTO, Y
    MAENO, M
    DAIKOKU, S
    ITOH, A
    HAZE, K
    YAMADA, N
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (08): : 577 - 581
  • [6] GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING ASSESSMENT OF HYDROXYAPATITE ORBITAL IMPLANTS
    SPIRNAK, JP
    NIEVES, N
    HOLLSTEN, DA
    WHITE, WC
    BETZ, TA
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 119 (04) : 431 - 440
  • [7] GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING IN FACIAL-NERVE LESIONS
    MILLEN, SJ
    DANIELS, D
    MEYER, G
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1990, 102 (01) : 26 - 33
  • [8] THE EFFECT OF INTRACRANIAL SURGICAL TRAUMA ON GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING
    MILLEN, SJ
    DANIELS, DL
    [J]. LARYNGOSCOPE, 1994, 104 (07): : 804 - 813
  • [9] GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING IN PATIENTS WITH PRESUMED LACUNAR INFARCTS
    SAMUELSSON, M
    LINDELL, D
    NORRVING, B
    [J]. CEREBROVASCULAR DISEASES, 1994, 4 (01) : 12 - 19
  • [10] GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING IN ACUTE MYOCARDIAL-INFARCTION
    VANDIJKMAN, PRM
    VANDERWALL, EE
    DEROOS, A
    DOORNBOS, J
    VANDERLAARSE, A
    MATHEIJSSEN, NAA
    VANROSSUM, AC
    VANVOORTHUISEN, AE
    BRUSCHKE, AVG
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1990, 11 (01) : 1 - 9