A round-robin programme has been undertaken to assess the compatibility in the micromechanical techniques used to evaluate the interfacial shear strength of the fibre/matrix bond in composite materials. The tests selected for evaluation were the single-fibre pull-out test, the microdebond test, the fragmentation test and the micro-indentation test. Twelve laboratories were invited to participate in this programme. Each laboratory was supplied with Caurtaulds XA fibre in the untreated condition and with a standard surface treatment, and a quantity of epoxy resin, hardener and catalyst, all from the same batch. Some laboratories were supplied with composite bars made with the same materials. A common cure cycle was chosen for sample preparation. Each laboratory conducted the tests to its own procedures. The results showed that the scatter within each laboratory was acceptable but the scatter between laboratories for a particular test was high. The results are discussed and possible explanations are presented for these observations. The indications are that the fundamental procedures used in each laboratory are sound. The results also suggest that there is great potential for achieving standard procedures and reducing the inter-laboratory scatter. A further round-robin programme is proposed to generate test protocols.
引用
收藏
页码:205 / 214
页数:10
相关论文
共 50 条
  • [1] ROUND-ROBIN TEST PARTICIPANTS SOUGHT
    LABREQUE, JJ
    ANALYTICAL CHEMISTRY, 1979, 51 (09) : A922 - A922
  • [2] Round-Robin Test on methods for determining chloride transport parameters in concrete
    M. Castellote
    C. Andrade
    Materials and Structures, 2006, 39
  • [3] Round-Robin Test on methods for determining chloride transport parameters in concrete
    Castellote, M.
    Andrade, C.
    MATERIALS AND STRUCTURES, 2006, 39 (10) : 955 - 990
  • [4] COMPARISON OF OUTDOOR AND ACCELERATED EXPOSURE METHODS - RESULTS OF A ROUND-ROBIN TEST
    不详
    JOURNAL OF COATINGS TECHNOLOGY, 1986, 58 (734): : 57 - 65
  • [5] ARFTG STREAMLINES ROUND-ROBIN CALIBRATION PROGRAM
    MANZ, BE
    MICROWAVES & RF, 1983, 22 (01) : 31 - &
  • [6] Round-robin study for field permeability test
    Cooley, L. Allen
    Maghsoodloo, Saeed
    Transportation Research Record, 2002, (1789) : 25 - 35
  • [7] Workshop: Status of the round-robin analysis test
    Hirokawa, K
    Nakamura, Y
    Abiko, K
    LeCoze, J
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 1997, 160 (02): : 557 - 560
  • [8] RESULTS OF ROUND-ROBIN TEST FOR DETERMINATION OF BOD
    TAKAMI, K
    ODA, K
    BUNSEKI KAGAKU, 1989, 38 (01) : T9 - T14
  • [9] Round-Robin Test of Heat Flux Sensors
    Turzo-Andras, E.
    Blokland, H.
    Hammerschmidt, U.
    Rudtsch, S.
    Stacey, C.
    Kroes, C.
    Magyarlaki, T.
    Nemeth, S.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (11-12) : 2708 - 2715
  • [10] Round-Robin Test of Heat Flux Sensors
    E. Turzo-Andras
    H. Blokland
    U. Hammerschmidt
    S. Rudtsch
    C. Stacey
    C. Krös
    T. Magyarlaki
    S. Nemeth
    International Journal of Thermophysics, 2011, 32 : 2708 - 2715