SUBJECTIVE EVALUATION OF IMAGE QUALITY BASED ON IMAGES OBTAINED WITH A BREAST-TISSUE PHANTOM - COMPARISON WITH A CONVENTIONAL IMAGE QUALITY PHANTOM

被引:10
|
作者
OLSEN, JB [1 ]
SAGER, EM [1 ]
机构
[1] NORWEGIAN RADIUM HOSP,DEPT RADIOL,N-0310 OSLO,NORWAY
来源
BRITISH JOURNAL OF RADIOLOGY | 1995年 / 68卷 / 806期
关键词
D O I
10.1259/0007-1285-68-806-160
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A breast tissue phantom was used for assessment of mammographic image quality. Three images, exposed to give a reference area film density of 1.25 +/- 0.03, were obtained for each of five different film/kV combinations. Each of three radiologists carried out a series of three blind readings, in which the 15 films were ranked according to sharpness and contrast. In a similar experiment with a conventional image quality phantom, scores for the visualization of simulated calcifications and contrast-detail performance, and measures for resolution and contrast were obtained. In both experiments, the judgements of the readers were highly consistent, and both the intraobserver and interobserver variabilities were non-significant. No significant differences between the film/kV combinations were found with respect to high-contrast resolution and visualization of the simulated calcifications. The contrast measures obtained with the conventional phantom correlated well with the contrast scores obtained with the breast tissue phantom. The contrast-detail scores obtained with the conventional phantom showed no correlation with the scores obtained with the breast tissue phantom, nor with the contrast measures obtained with the conventional phantom.
引用
收藏
页码:160 / 164
页数:5
相关论文
共 50 条
  • [1] Computerized evaluation of mammographic image quality using phantom images
    Dougherty, G
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1998, 22 (05) : 365 - 373
  • [2] Comparison of computer analysis of mammography phantom images (CAMPI) with perceived image quality of phantom targets in the ACR phantom
    Chakraborty, DP
    [J]. IMAGE PERCEPTION: MEDICAL IMAGING 1997, 1997, 3036 : 160 - 167
  • [3] Automatic evaluation of the image quality of a mammographic phantom
    Mayo, P
    Rodenas, F
    Verdú, G
    Villaescusa, JI
    Campayo, JM
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2004, 73 (02) : 115 - 128
  • [4] A new test phantom with different breast tissue compositions for image quality assessment in conventional and digital mammography
    Pachoud, M
    Lepori, D
    Valley, JF
    Verdun, FR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (23): : 5267 - 5281
  • [5] Image quality of conventional images of dual-layer SPECTRAL CT: A phantom study
    van Ommen, Fasco
    Bennink, Edwin
    Vlassenbroek, Alain
    Dankbaar, Jan Willem
    Schilham, Arnold M. R.
    Viergever, Max A.
    de Jong, Hugo W. A. M.
    [J]. MEDICAL PHYSICS, 2018, 45 (07) : 3031 - 3042
  • [6] Breast tomosynthesis: Dosimetry and image quality assessment on phantom
    Meyblum, E.
    Gardavaud, F.
    Dao, T. -H.
    Fournier, V.
    Beaussart, P.
    Pigneur, F.
    Baranes, L.
    Rahmouni, A.
    Luciani, A.
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (09) : 931 - 939
  • [7] Computerized analysis of mammographic phantom images: An image quality evaluation system for mammography
    Chakraborty, DP
    Zhao, XM
    Gingold, EL
    Sullivan, DC
    [J]. RADIOLOGY, 1996, 201 : 834 - 834
  • [8] A quantitative method for visual phantom image quality evaluation
    Chakraborty, D
    Liu, X
    O'Shea, M
    Toto, L
    [J]. MEDICAL IMAGING 2000: IMAGE PERCEPTION AND PERFORMANCE, 2000, 3981 : 24 - 33
  • [9] EVALUATION OF PORTAL IMAGE QUALITY USING DEDICATED PHANTOM
    Blasiak, B.
    Litoborski, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S550 - S550