Variability in measurement of acetabular index

被引:1
|
作者
Ibanez L, Angelica [1 ]
Ramirez M, Constanza [2 ]
Hodgson O, Felipe [1 ]
Valenzuela V, Joaquin [2 ]
Karzulovic B, Lorena [3 ]
Llanos C, Jorge [4 ]
Izquierdo P, Guillermo [5 ]
Valdes S, Macarena [6 ]
机构
[1] Pontificia Univ Catolica Chile, Traumatol, Dept Traumatol & Ortopedia, Santiago, Chile
[2] Pontificia Univ Catolica Chile, Traumatol & Ortopedia, Santiago, Chile
[3] Pontificia Univ Catolica Chile, Pediat, Santiago, Chile
[4] Pontificia Univ Catolica Chile, Dept Radiol, Santiago, Chile
[5] Pontificia Univ Catolica Chile, Interno Ano Med 7, Santiago, Chile
[6] Pontificia Univ Catolica Chile, Tecnol Med, Unidad Invest, Dept Traumatol & Ortopedia, Santiago, Chile
来源
REVISTA CHILENA DE PEDIATRIA-CHILE | 2013年 / 84卷 / 02期
关键词
Developmental dysplasia of the hip (DDH); acetabular index; intra-observer variability; inter-observer variability; radiography;
D O I
10.4067/S0370-41062013000200006
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Developmental dysplasia of the hip (DDH) is a spectrum of diseases ranging from frank dislocation of the hip to mild acetabular dysplasia. DDH screening for detection is performed routinely in our country using pelvic x-ray at 3 months of age. The radiographic measured acetabular index is used to evaluate the dysplastic hip. at initial presentation and during follow-up. Objective: Evaluation of the intra- and inter-observer variability, among medical professionals, when measuring acetabular index. Methods: Four reviewers (a children orthopedic surgeon, a general practitioner, a pediatrician and a radiologist) performed acetabular index measurement in 100 radiographs (200 hips), on three occasions, separated each by one month (600 total measurements). An independent observer evaluated the measurement reproducibility. The intra-class correlation coefficient to determine significant differences was used. Results: The intra-observer variability was less than the inter-observer variability. The intra-observer variability was similar among the different assessors, +/- 1.5 degrees. The inter-observer variability was +/- 3.4 degrees. Conclusions: A high concordance among measurements was reported, evidencing a high reproducibility of the acetabular index; this index is a reliable method for the diagnosis and follow-up of acetabular dysplasia.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 50 条
  • [1] Variability in measurement of the acetabular index in normal and dysplastic hips
    Skaggs, DL
    Kaminsky, CK
    Hale, JM
    Reynolds, RAK
    [J]. PEDIATRICS, 1997, 100 (03) : 481 - 482
  • [2] Variability in the assessment of acetabular index
    Kay, RM
    Watts, HG
    Dorey, FJ
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1997, 17 (02) : 170 - 173
  • [3] Variability in measurement of acetabular index in normal and dysplastic hips, before and after reduction
    Skaggs, DL
    Kaminsky, C
    Tolo, VT
    Kay, RM
    Reynolds, RAK
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1998, 18 (06) : 799 - 801
  • [4] ERRORS IN MEASUREMENT OF ACETABULAR INDEX
    PORTINARO, NMA
    MURRAY, DW
    BHULLAR, TPS
    BENSON, MKD
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1995, 15 (06) : 780 - 784
  • [5] Measurement of acetabular index intraobserver and interobserver variation
    Spatz, DK
    Reiger, M
    Klaumann, M
    Miller, F
    Stanton, RP
    Lipton, GE
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1997, 17 (02) : 174 - 175
  • [6] Differing acetabular index variability in normal, dysplastic, and reduced hips
    Kaminsky, CK
    Fahmy, JL
    Parisi, MT
    Reynolds, RR
    Skaggs, DL
    [J]. RADIOLOGY, 1997, 205 : 1031 - 1031
  • [7] Measuring the Acetabular Index: An Accurate and Reliable Alternative Method of Measurement
    Sherman, Benjamin
    Lalonde, Francois D.
    Schlechter, John A.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 217 (01) : 172 - 176
  • [8] Reliability of the sourcil method of acetabular index measurement in developmental dysplasia of the hip
    Maddock, C. L.
    Noor, S.
    Kothari, A.
    Bradley, C. S.
    Kelley, S. P.
    [J]. JOURNAL OF CHILDRENS ORTHOPAEDICS, 2019, 13 (02) : 167 - 171
  • [9] Application of deep-learning-based artificial intelligence in acetabular index measurement
    Wu, Qingjie
    Ma, Hailong
    Sun, Jun
    Liu, Chuanbin
    Fang, Jihong
    Xie, Hongtao
    Zhang, Sicheng
    [J]. FRONTIERS IN PEDIATRICS, 2023, 10
  • [10] Reliability of digital measurement of acetabular index in hip dysplasia to the time children start walking
    Dornacher, D.
    Calkir, B.
    Reichel, H.
    Nelitz, M.
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2008, 146 (02): : 246 - 250